MAURY USCG vessel records Sign in
← All vessels

WARSAW

WARSAW is a 1976 freight ship. The Coast Guard has recorded 78 inspections since 1984, most recently in January 2009, along with 40 deficiencies and 6 operational controls.

Records from 1984 to 2009. Most recent: inspection, 3 January 2009.

Built
1976
Last inspected
3 January 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7407013 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225038
Flag
MARSHALL ISLANDS
—
Maury page id
psix-225038

Inspections, by type

…with no type recorded54
Years with a record 22 calendar years (1984–2009)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30528 - Convention (Subpart B), Gross Ton
50250 - Dead Weight, Ton
16997 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 8

Inspection history · 78

3 January 2009 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3385253
19 June 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3240772
7 April 2008 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3179234
28 January 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3137675
20 October 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3084452
9 June 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2955997
23 May 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2937925
10 April 2007 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2905259
9 February 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2869845
18 January 2007 Random ISPS/MTSA-No PSC
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2858205
9 September 2006 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2773774
23 August 2006 ISPS II Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2758021
11 July 2006 Type not recorded
No type recorded · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2710576
24 March 2006 PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2608800
29 November 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2542988
14 October 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2514568
6 May 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2351204
22 April 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2340337
19 April 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2337858
4 March 2005 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2303764
27 February 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2300460
25 February 2005 Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2297651
25 February 2005 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2299541
12 November 2004 NPV Safety Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2241248
12 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242940
12 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242945
21 October 2004 ISPS II Exam
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2225436
26 July 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2146721
22 July 2004 ILO-147 Exam · ISM Exam · STCW 95 Exam · PII Safety Exam · MARPOL Annex I Examination · Loadline Exam · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2141629
6 May 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2061101
1 December 2003 MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1956967
17 October 2003 Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1932390
9 October 2003 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1924681
27 August 2003 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1888600
21 June 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1826751
2 May 2003 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1785148
6 March 2003 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1753439
5 March 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1753035
31 January 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1766898
28 October 2002 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1697794
21 October 2002 Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1693214
20 July 2002 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1657239
1 July 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1634502
10 June 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1624325
13 April 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1610658
3 April 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600477
1 September 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 419853
21 March 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 402136
13 February 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 375161
7 February 1995 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 375023
13 December 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 675953
3 December 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 372946
11 August 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 369258
6 August 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 369154
6 August 1994 MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1392060
22 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 364717
21 June 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 464952
15 June 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 358847
15 June 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 675954
12 June 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 358898
19 February 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 493800
11 February 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 356298
4 September 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 463345
13 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 443198
8 June 1992 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 351322
28 February 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 440934
11 May 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 485916
8 November 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 340241
10 September 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 464848
27 December 1988 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 327573
9 November 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 319354
24 June 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 316735
24 February 1987 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 532969
2 July 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 309900
25 April 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 308256
29 July 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 303400
3 June 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 501707
5 October 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 298240

Deficiency record · 40

Electrical › Lighting (service) › Lighting Fixture
Issued 25 February 2005 Resolved
Cover all missing light guards in fwd workshop, engine room, CC no.1 space and provision storage.
Condition: Improper/Lack of Maintenance
Due 11 March 2005
Resolved 27 February 2005
Electrical › Electric Supply System (service) › Cable
Issued 25 February 2005 Resolved
Remove dead end wiring from fwd workshop and hydraulic pumproom.
Condition: Improper/Lack of Maintenance
Due 11 March 2005
Resolved 27 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 25 February 2005 Resolved
Damage to hull at waterline on forward port quarter: Repair to the satisfaction of Class Society.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2005
Construction/Loadline › Penetrations › Weld
Issued 25 February 2005 Resolved
Repair/Crop and renew holed deck in dry provisions stores. Temporary repair in place. A doubler was fitted over hole until permanent repairs and UT gauging can be carried out on the tanktop of Tank 36 by March 27, 2005.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2005
Resolved 6 May 2005
Resolution: Received verification from certificate issuing authority attesting to the satisfaction of permanent repairs of deck in dry provision stores.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 February 2005 Resolved
Vessel storing flammable liquids in non protected spaces (fwd hydraulic pump room and aft steering)
Due 11 March 2005
Resolved 27 February 2005
Construction/Loadline › Structures › Trunk
Issued 12 November 2004 Resolved
Approximately 15 feet of the starboard bow bullwarks and handrails damaged from collision
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 December 2004
Resolved 27 February 2005
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 22 July 2004 Resolved
Class to attest to the acceptability of modifications to class A bulkhead between galley and crews mess NLT 24AUG04
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2004
Resolved 20 August 2004
Resolution: Received class report attesting to proper extention of hotplate/serving unit with use of proper steel for bulkheads. New steel door added (class A-0) to rear end of unit. All modifications were upgrades of original and acceptable to class.
Engineering › Steering Gear System › Piping
Issued 22 July 2004 Resolved
Provide report from class attesting to the satifactio of the weld repair on the high pressure piping for the steering gear.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2004
Resolved 20 August 2004
Resolution: Received class report attesting that weld repair in question (to high pressure pipe for steering gear) is acceptable and similar to original. Steering gear tested under full pressure without problems.
Fire Fighting › Fire Pumps
Issued 1 December 2003 Resolved
Replace/repair motor on #1 Fire pump prior to departure. Send report attesting repairs to attending US Coast Guard Inspectors. LEGACY COMPONENT DESC: Power Source
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2003
Resolution: Cleared via fax received 04DEC03
Construction/Loadline › Hull
Issued 6 March 2003 Resolved
missing liferails on STBD side.
Condition: Damaged By Earlier Event
Due 5 April 2003
Resolved 2 May 2003
Resolution: Welded new section of rail.
Construction/Loadline › Hull
Issued 6 March 2003 Resolved
life rails on port side are missing/and some are in need of repair LEGACY COMPONENT DESC: life rails
Condition: Improper/Lack of Maintenance
Due 5 April 2003
Resolved 2 May 2003
Resolution: Welded new section of rail.
Electrical › Electrical Distribution System (service)
Issued 6 March 2003 Resolved
dead end wire's in bow area are not properly secured, and verification from chief mate that wires were live. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 5 April 2003
Resolved 2 May 2003
Resolution: Wires were removed.
Navigation › Piloting/Steering
Issued 6 March 2003 Resolved
after steering compass was reading approximately 25 degrees off from main compass, and cerw/master was unaware of actual inaccuracy . calibrate aft compass for proper operational readings. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Improper/Lack of Maintenance
Due 5 April 2003
Resolved 7 May 2003
Resolution: improperly issued, not required due to keel laid date
Electrical › Electric Supply System (service)
Issued 10 June 2002 Resolved
Various deadend wires found behind OWS and above stripping pump in engine room. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: Attended vsl wires remove as per class report
Engineering › Fuel Oil Service System
Issued 10 June 2002 Resolved
F/O Leak from flange above OWS piping gasket needs replaced LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: Attended vsl F/O leak repaired as per class report
Pollution Prevention/Response › Prevention Equipment
Issued 10 June 2002 Resolved
OWS inopertive unable to test system LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: Attended vsl OWS working properly as per class report
Pollution Prevention/Response
Issued 10 June 2002 Resolved
Exicessive water/oil in bilge area
Action required: 15 - Rectify deficiencies by next port
Due 10 July 2002
Resolved 12 June 2002
Resolution: vsl pumped bilge as per class report
Engineering › Sea-water System (primary cooling)
Issued 10 June 2002 Resolved
Various handwheels missing from gen set s/w system inlet and outlet of the aftercooler. 5 out of the 6 valve handwheels are missing.
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 1 July 2002
Resolution: VERIFIED CORRECT DURING PSC DEFICIENCY FOLLOW UP EXAM. DEFICIENCY CLEARED.
Engineering › Sea-water System (primary cooling)
Issued 10 June 2002 Resolved
Excessive water leaks # 2 main S/W system pump LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: Attended vsl repairs to the S/W pump complete as per class report
Electrical › Electric Generation Source (emergency)
Issued 10 June 2002 Resolved
Electrical matting missing from swicthboard
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 12 June 2002
Resolution: Attended vsl elect mat placed in space as per class report
Engineering › Steering Gear System
Issued 10 June 2002 Resolved
No non-skid surface in after steering, hydr leaks found on the deck
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 1 July 2002
Resolution: VERIFIED CORRECT DURING PSC DEFICIENCY FOLLOW UP EXAM. DEFICIENCY CLEARED.
Fire Fighting › Fire Pumps
Issued 10 June 2002 Resolved
Emer fire pump compartment flooded, unable to run pump LEGACY COMPONENT DESC: Arrangement
Action required: 17 - Rectify deficiencies prior to departure
Due 11 June 2002
Resolved 12 June 2002
Resolution: Attended vsl test ran fire pump as per class report
Documentation › Logs/Records
Issued 10 June 2002 Resolved
ISM 10.2.2 no records of maintanace problems kept on vessel , need audit complete
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2002
Resolved 12 June 2002
Resolution: ISM audit conducted by GL
Construction/Loadline
Issued 21 March 1997 Resolved
Remove hose from aft galley bulkhead and make permanent repairs to bulkhead, have class inspect prior to departing San Francisco bay.
Condition: Unknown
Due 27 March 1997
Resolved 4 April 1997
Construction/Loadline
Issued 21 March 1997 Resolved
Permanently repair hole in foward bulkhead in forward paint locker foward of cargo holds. Have class inspect prior to departing San Francisco bay.
Condition: Unknown
Due 27 March 1997
Resolved 4 April 1997
Accommodation/Occupational Safety
Issued 21 March 1997 Resolved
Have class inspect all emergancy escape doors for missing or inop closing devices. Prior to departing San Francisco bay.
Condition: Unknown
Due 27 March 1997
Resolved 4 April 1997
Construction/Loadline
Issued 21 March 1997 Resolved
Have class inspect funnel door port side, for the silver dollar size hole. Prior to departing San Francisco bay.
Condition: Unknown
Due 27 March 1997
Resolved 4 April 1997
Construction/Loadline
Issued 21 March 1997 Resolved
Have class inspect cracks found on main deck gussets on cargo holds. #2 port, #5 starboard, and #4 port. Prior to next US port from overseas.
Condition: Unknown
Due 27 March 1997
Resolved 4 April 1997
Engineering
Issued 21 March 1997 Resolved
Have class inspect the following patches in the engine room: main engine sea water discharge line # 1-2 pump, ballast pump discharge patched, overboard generator line patched, hydraulic leaks in engine control room, bunker tank # 41 leaking.
Condition: Unknown
Due 27 March 1997
Resolved 4 April 1997
Fire Fighting
Issued 21 March 1997 Resolved
Adjust all fire doors and ensure that they close properly. Have class inspect prior to departing San Francisco bay.
Condition: Unknown
Due 27 March 1997
Resolved 4 April 1997
Lifesaving
Issued 21 March 1997 Resolved
Perform satisfactory abandon ship and fire drills for the Coast Guard priorto departing San Francisco Bay.
Condition: Unknown
Due 27 March 1997
Resolved 1 April 1997
Engineering
Issued 21 March 1997 Resolved
Repair/replace the main engine dampers to ensure that they close properly. Prior to departing San Francisco Bay.
Condition: Unknown
Due 27 March 1997
Resolved 1 April 1997
Navigation
Issued 3 December 1994 Resolved
M/V SEAGUARDIAN TRANSITED THE COLUMBIA AND WILLAMETTE RIVERS WITH CHARTS 18521, 18523, AND 18524 NOT CURRENTLY CORRECTED WITH NOTICE TO MARINERS.
Condition: Unknown
Due 13 February 1995
Resolved 13 February 1995
Fire Fighting
Issued 6 August 1994 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 12 August 1994
Resolved 12 August 1994
Accommodation/Occupational Safety
Issued 12 June 1993 Resolved
M/V SEAGUARDIAN VIOLATED MARPOL ANNEX V, 33 C.F.R. 151.67 ARRIVING IN WILMINGTON, NC FROM NEW BRUNSWICK, CANADA WITH NO PLASTICS IN THE VESSEL'S TRASH.
Condition: Unknown
Due 24 June 1993
Resolved 24 June 1993
Engineering
Issued 8 June 1992 Resolved
15 PPM OILY WATER SEPERATOR ALARM WAS INOPERABLE. DEVIATION WAS GRANTED FOR VESSEL TO DEPART PORT. PERMANENT REPAIR IS TO BE MADE IN NEXT U.S. PORT WHEN PART IS RECEIVED. NO OVERBOARD DISCHARGE OR PUMPING OF BILGES ISPERMITTED UNTIL REPAIR IS MADE.
Condition: Unknown
Due 11 February 1993
Resolved 11 February 1993
Navigation
Issued 24 June 1987 Resolved
VESSEL DID NOT HAVE TIDAL CURRENT TABLES OR FOREIGN GOVERNMENT EQUIVALENTS ON BOARD AS REQUIRED BY 33CFR164.33(A)(3)(II).
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Accommodation/Occupational Safety
Issued 24 June 1987 Resolved
VESSEL IS EQUIPPED WITH INSTALLED TOILETS AND WAS FOUND OPERATING WITH THE TYPE II MSD ON BOARD BYPASSED DISCHARGING RAW SEWAGE DIRECTLY OVERBOARDIN VIOLATION OF 33CFR159.7.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Navigation
Issued 24 June 1987 Resolved
PROVIDE STEERING GEAR REMOTE POWER AND CONTROL SYSTEMS BLOCK DIAGRAM & OPERATING INSTRUCTIONS ON THE BRIDGE & IN STEERING GEAR ROOM IN ACCORDANCE WITH 33CFR164.35(K).
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Fire Fighting
Issued 24 June 1987 Resolved
PROVIDE FIRE CONTROL PLANS IN A PROMINENTLY MARKED WEATHER TIGHT CONTAINER OUTSIDE THE DECKHOUSE ON BOARD.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.