Records from 2016 to 2020. Most recent: inspection, 19 February 2020.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 13
19 February 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6911880
19 November 2019
ACP Additional Oversight – Risk Assessment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6886172
15 November 2019
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6856383
30 October 2019
ACP Additional Oversight – Risk Assessment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6845654
5 September 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6804568
2 July 2019
Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6733665
2 May 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6676005
20 March 2019
Periodic Inspection · ACP Annual Oversight · ACP Periodic Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6649295
19 March 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6645522
16 May 2018
Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6405026
17 August 2017
Annual Inspection · ACP Annual Oversight · Annual Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · Security Plan Review - VSP · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6242768
8 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6037388
20 May 2016
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5882302
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 November 2019
Resolved
WEATHER TIGHT DOORS SHALL BE WEATHER TIGHT WHEN CLOSED, MAIN DECK PORT WX TIGHT DOOR CANNOT BE DOGGED WEATHERTIGHT (POSN 1).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2019
Resolved 2 November 2019
Resolution: CREW RE-SHIMMED DOOR. ABS ATTENDED CHALK TEST SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2019
Resolved
ELECTRICAL EQUIPMENT SHALL BE SUITABLE FOR SERVICE. PILOT HOUSE A/C SUPPLY CABLE CHAFFING ON JUNCTION BOX KNOCKOUT.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 15 November 2019
Resolution: REMOUNTED ACCEPTED PHOTO.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 November 2019
Resolved
LIFESAVING APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER READY FOR IMMEDIATE USE. STARBOARD BRIDGE WING
RING BUOY/SMOKE BECKET LINES WORN/UV DAMAGE, REPLACE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 15 November 2019
Resolution: BECKET LINES RENEWED, ACCEPTED PHOTO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2019
Resolved
ELECTRICAL EQUIPMENT SHALL BE SUITABLE FOR SVC UNLESS OTHERWISE SPECIFIED MEET SUB J. OUTLET FOR WASHER IS ON E-CIRCUIT, TEMP CORDS PIGGYBACKED TO REACH WASHER CORD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2019
Resolved 19 November 2019
Resolution: ABS ATTENDED. CORDS REMOVED. OUTLET MARKED E-CIRCUIT. NEW OUTLET INSTALLED FOR WASHER AVOIDS EXTENSION CORDS.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 November 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 1 November 2019
Resolved 1 November 2019
Resolution: CONDUCTED SECOND DRILL.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 November 2019
Resolved
FIREFIGHTING EQUIPMENT MUST BE ONBOARD IN THE PRESCRIBED LOCATION READY FOR USE. CO2 BOTTLE FOR RESCUE BOAT FLAMMABLE STORAGE LOCKER BRACKET RETENTION BAND WASTED/BROKEN.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 15 November 2019
Resolution: ACCEPTED PHOTO
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 November 2019
Resolved
THE COMPANY & SHIP SHALL COMPLY WITH THE REQUIREMENT
OF THE ISM CODE. ITEMS ABOVE; #1,2,3,4,5,7 PROVIDE
OBJECTIVE EVIDENCE THAT ISM CODE ELEMENTS 7 & 10 ARE NOT
BEING IMPLEMENTED FULLY. RECOMMEND AN INTERNAL AUDIT BE COMPLETED BY 15JAN2019 WITH A SPECIFIC FOCUS ON THE AREAS NOTED ABOVE.
Action required: 705 - Other - as specified
Due 15 January 2020
Resolved 5 January 2020
Resolution: ABS REVIEWED INTERNAL AUDIT, CAR. BOTH SUBMITTED TO ABS AND CG. SAT.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 30 October 2019
Resolved
THE MASTER SHALL VERIFY THE VESSEL IS IN COMPLIANCE WITH STABILITY REQUIREMENTS. TEMP SATELLITE DOME W/FOUNDATION ONBOARD 02 DECK UNKNOWN WIEGHT/VCG VALUES, OBTAIN ACTUAL
VALUES. CONSERVATIVE EST INDICATES COMPLIANCE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 15 November 2019
Resolution: ACCEPTED VENDOR DOCUMENTATION(WIEGHT/VCG) AND ADDITION OF SAME TO LOADMASTER COMPUTER MODEL ONBOARD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2019
Resolved
ELECTRICAL EQUIPMENT SHALL BE SUITABLE FOR SERVICE.ELECTRICAL JUNCTION BOX ON AFT ACCOM AIR HANDLER BROKE LOOSE FROM MOUNT CHAFFING/ELECTRICAL HAZARD. DRYER OUTLETS,AFT ACCOMODATION LAUNDRY MISSING COVERS.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2019
Resolved 19 November 2019
Resolution: ABS ATTENDED, REMOUNTED BOX.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 April 2019
Resolved
Overspeed protection shall be provided for generators. Generator NO 3 did not shut down on overspeed operational test.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2019
Resolved 9 April 2019
Resolution: REPAIRED
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 April 2019
Resolved
Watertight doors shall prevent the passage of water at a designed head of pressure. WTD E/R to Tank farm not watertight out of adjustment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2019
Resolved 9 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 April 2019
Resolved
Watertight doors shall prevent the passage of water at a designed head of pressure. WTD Bow Thruster to EOS, out of adjustment
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 April 2019
Resolved 5 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 April 2019
Resolved
Following Fire Screen Doors (FSDs) w/self closing not operational, do not self latch/close; FSD(s) for galley including the sliding serving door activated by the release of fixed fire system, FSD for laundry room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2019
Resolved 9 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2019
Resolved
Suitable guards must be installed in locations of dangerous rotating machinery. Steering gear motor fan guard loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2019
Resolved 9 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 April 2019
Resolved
Flame screen for gear oil tank missing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2019
Resolved 9 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 20 March 2019
Resolved
UPDATE SAFETY/FIRE CONTROL PLAN TO REFLECT IMMERSION SUIT LOCKER, REMOVAL OF EMERG EVAC LOCKER, REFLECT CURRENT GA, OBTAIN [name withheld].
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2019
Resolved 27 March 2019
Resolution: New FCP onboard, reflects current PAM install.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 20 March 2019
Resolved
MARK IMMERSION SUITES WITH VESSEL NAME. MARK IMMERSION SUIT LOCKER WITH REQD IMO SIGNAGE/MARKING.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2019
Resolved 27 March 2019
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 March 2019
Resolved
DEMONSTRATE GENERAL ALARM/PA IS AUDIBLE IN MUD LAB, TIE IN FIRE ALARM OF SAME TO SHIP SYSTEM AS APPLICABLE.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2019
Resolved 27 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2019
Resolved
REMOVE TEMPORARY EXTENSION CORDS ON DECK FOR PIPING HEAT TAPE.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2019
Resolved 27 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 20 March 2019
Resolved
ELEVATED WALKWAY STRUCTURAL SUPPORTS WASTED THROUGH IN WAY OF WORK BOAT & GANGWAY, PORT SIDE. FLEXING UNDER WIEGHT OF NORMAL TRAFFIC, REPAIR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2019
Resolved 2 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 March 2019
Resolved
INSTALL METALIC CABLE TIES TO OVERHEAD PAM CABLE TRAYS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2019
Resolved 2 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2019
Resolved
PROVIDE APPROVED ACP RO/CLASS PLANS TO REFLECT CURRENT PAM INSTALLATION(GA/INSTALL/ELECTRICAL TIE IN TO SHIP) Ref CG-ENG Policy Letter No.01-16
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2019
Resolved 2 July 2019
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 7 June 2016
Resolved
During annual ACP examination several lifesaving and firefighting equipment was found to be inadequate condition. Based on the finding during this examination, the RO and ABS shall conduct an external audit of the SMS related to the vessels Lifesaving and fire-fighting equipment. The results of the audit shall be submitted to MSU Morgan City, LA. SOLAS IX/4 Reg 5/ISM Code 6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2016
Resolved 6 September 2016
Resolution: Spot checked life floats, life jackets, and SCBA bottles, All sat. Reviewed maintenance procedures and made recommendations to vessel rep.