Records from 2005 to 2025. Most recent: inspection, 17 June 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2005
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
17 June 2025
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8150347
22 May 2025
Drydock Exam · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8153102
18 April 2023
MTSA Verification · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7667184
23 March 2019
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6727545
15 May 2018
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6414813
26 February 2018
COI Inspection · MTSA Verification · Deficiency Check · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6359682
29 August 2016
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5986844
22 March 2016
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5838477
12 March 2015
Drydock Exam · COI Inspection · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5082906
5 February 2014
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4794873
6 March 2012
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4257553
26 January 2011
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3932447
9 February 2010
COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3677492
10 July 2009
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3530578
12 June 2009
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3489855
13 May 2008
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3197168
8 June 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2955275
28 November 2006
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2830215
28 November 2006
Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2831807
15 August 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2748584
31 May 2006
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2666084
24 March 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2318529
22 March 2005
Cargo Tank Internal · Initial Construction-Excluding Oversight · Internal Structural Exam · MTSA Verification · Hull Examination · Initial Certification · Deadweight Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2301386
Engineering › Diesel Engine (auxiliary) › Block
Issued 29 August 2016
Resolved
Cargo pump engine and engine housing damaged in collision. Repair and demonstrate proper operation to the satisfaction of the attending marine inspector, to include test of emergency shutdown.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2018
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 29 August 2016
Resolved
Portside manifold damaged in collision. Repair and conduct appropriate hydrostatic, tightness, and electrical continuity tests to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2018
Resolution: Witnessed Hydrostatic test at 1.5x MAWP
Construction/Loadline › Hull › Hull Plating
Issued 12 June 2009
Resolved
1.5" fracture found on stbd side of stern box deck knuckle.
Action required: 705 - Other - as specified
Due 18 July 2009
Resolved 10 July 2009
Resolution: Conducted repair check. Examined welds. Found satisfactory.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 31 May 2006
Resolved
Provide satisfactory documentation to [name withheld]/Galveston that this vessel has operated in fresh water service at least 6 of the last 12 months. If the vessel has not been operated in fresh water service at least 6 of the last 12 months or satisfactory documentation cannot be provided, the vessel will be required to be inspected IAW the salt water intervals prescribed in 46 CFR 31.10-21(a)(1)
Action required: 705 - Other - as specified
Due 1 July 2006
Resolved 15 August 2006
Resolution: Fresh Water service verified for 6 of the last 12 months of service.