Inspection history · 25
22 June 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8410742
20 August 2025
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8219803
2 June 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8142399
31 May 2024
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7923978
30 April 2024
Deficiency Check · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7904177
30 November 2023
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7831876
18 October 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7806356
10 May 2023
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7685384
25 October 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7583872
17 March 2022
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7413510
12 January 2022
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7379130
11 January 2022
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7387300
6 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7376505
30 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7363541
25 October 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7318791
6 October 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7070373
24 July 2020
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7074117
19 February 2019
Deficiency Check · Initial Certification · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6628159
21 March 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5837494
22 February 2016
DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5822143
1 June 2012
Industry Initiated Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4333631
9 March 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4268272
18 November 2011
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4197165
23 August 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 654482
10 August 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 137433
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 June 2026
No resolution recorded
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Vessel's STBD side light is inoperable. Repair or replace within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 June 2026
No resolution recorded
(b) To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover.
(c) The valve must be installed in the fuel piping directly outside of the fuel oil supply tank.
(d) The valve must be operable from a safe place outside the space where the valve is installed. Vessel's installed nitrogen remote fuel shut off was unable to be tested from remote activation location. Demonstrate proper operation of remote fuel shut offs IAW manufacturer instructions and vessel procedures within 14 Days.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2026 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 June 2026
No resolution recorded
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions.
(b) Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. All other essential systems: every 3 months. Vessel failed to test and record remote fuel shut-off system IAW manufacturer instructions every 3 months.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2026 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 June 2026
No resolution recorded
Drills and instruction. The master of a towing vessel must ensure that each crew member participates in fire-fighting drills and receives instruction at least once each month. The instruction may coincide with the drills, but is not required to do so. All crew members must be familiar with their fire-fighting duties, and, specifically how to:
(1) Fight a fire in the engine room and elsewhere on board the towing vessel, including how to:
(iii) Operate the fuel shut-off(s) for the engine room. Vessel does not have Fuel shut off operation listed on drill list.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2024
Resolved
Each towing vessel must carry at least one appropriately-sized life jacket, approved under approval series 160.002, 160.005, 160.055, 160.155, or 160.176, for each person on board. 12 Vessel life jackets are not of the approved type, replace life jackets with approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 May 2024
Resolution: Vessel has provided photos of 12 approved type 1 PFDs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 April 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Both generators have dirt and oil in windings, clean windings to the satisfaction of attending inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2024
Resolution: Received photos of clean windings.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 October 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting source must provide for sufficient illumination under emergency conditions to facilitate egress from each space.
The emergency lighting in the engine room was not illuminating. Make repairs to lighting to make it sufficient to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Multiple shipboard lighting had broken light covers, replace covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 October 2023
Resolved
The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more then 10 percent.
The control air receiver in the engine room has a relief valve that exceeded the MAWP of the pressure vessel by more than 10 percent, replace relief valve that meets the standard to the satisfaction of the MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 October 2022
Resolved
The semi portable extinguisher hasn't been serviced since March 2021.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2022
Resolution: Verified the semiportable extinguisher was on board and appropriately serviced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 October 2021
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive oil was found in the engine room bilge. Remove excessive oil accumulation and clean to the satisfaction of a CG marine inspector prior to further operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2021
Resolution: Received photographic evidence that bilges were pumped out and cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 October 2021
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. 8 of 12 required lifejackets were found in an unserviceable condition. Remove and replace deteriorated lifejackets with new ones with required attachments (lights/whistles). Vessel may only carry a maximum of four people (including crew) until additional lifejackets are placed onboard.
Action required: 705 - Other - as specified
Resolved 30 November 2021
Resolution: New PFDs installed meeting requirements.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 October 2021
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Vessel's starboard running light was found inoperable. Replace/repair as necessary to satisfaction of CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 27 October 2021
Resolution: Received photograph of working starboard running light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2021
Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either: (1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or (2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or (3) Another suitable steel container that provides an equivalent level of protection. Vessel's flammable storage cabinet is corroded and not attached to the deck. Replace/remove storage cabinet as necessary to satisfaction of CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 27 October 2021
Resolution: Received photograph showing flammable liquids locker had been removed from vessel.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 25 October 2021
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Engine room exhaust stack openings do not have a closure device. Install closure device to satisfaction of CG marine inspector.
Action required: 705 - Other - as specified
Due 25 November 2021
Resolved 17 March 2022
Resolution: Vessel has installed new ventilation closure devices.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 25 October 2021
Resolved
A towing vessel must be maintained so the watertight integrity and stability of the vessel are not compromised. Stern watertight hatch is bent and there is a hole in the aft deck allowing water ingress. Temporary repairs immediately and permanent repairs in 30 days.
Action required: 705 - Other - as specified
Due 25 November 2021
Resolved 17 March 2022
Resolution: Stern watertight hatch has been repaired with new hinge allowing for watertight closure.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 25 October 2021
Resolved
Each towing vessel must be fitted with a general alarm that: Is capable of notifying persons in any accommodation, work space, and the engine room. The audible general alarm in the engine room is inoperable. Conduct repairs to satisfaction of CG marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2021
Resolved 27 October 2021
Resolution: Received video showing operable audible general alarm.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 October 2020
Resolved
01 - Each towing vessel must be fitted with a general alarm that is capable of notifying persons in any accommodation, work space, and the engine room. Vessels audible alarm was non-operational at the time of the inspection. Affect appropriate repairs and notify the USCG upon completion of a satisfactory test of the General Alarm. Complete by 08Oct20.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2020
Resolved 8 October 2020
Resolution: Vessel operator provided photographic evidence that the general alarm was fully operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 February 2019
Resolved
Unable to test main engine and generator alarms during inspection. Tech report required attesting to satisfactory testing of all required main engine and generator alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2019
Resolved 11 March 2019
Resolution: Port Engineer tested and verified alarms
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 February 2019
Resolved
Lifebuoy located on port bow is damaged and must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2019
Resolved 8 March 2019
Resolution: Received photographic evidence of new lifebouy installed.