Records from 2008 to 2025. Most recent: inspection, 3 June 2025.
Inspection history · 27
3 June 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8150741
19 May 2025
Cargo Tank Internal · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8139214
10 February 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8077353
9 September 2024
Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7999910
18 March 2024
MARPOL Annex IV Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex VI Survey · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7881218
10 August 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7769201
26 June 2023
Damage Survey · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7764989
15 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7637316
21 December 2022
MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7611654
15 December 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7609812
12 July 2022
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7504069
10 June 2021
MTSA/ISPS Verification · MARPOL Annex II Examination · Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7221577
23 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7181466
11 March 2021
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7154591
22 February 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7156500
9 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6937579
1 April 2020
MARPOL Annex II Examination · MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6933992
17 March 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6927807
9 October 2019
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6831647
8 October 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6832217
29 April 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6672406
9 April 2019
MARPOL Annex IV Survey · Annual Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6658705
11 January 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6608988
6 March 2018
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6366613
11 December 2017
Examination of Repairs · Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6322669
16 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6147941
18 May 2016
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5880752
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 June 2025
Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition. The owner or builder shall make the vessel and its equipment available for inspection, including the following items: (m) Fire hazards. Vessel bilges were found with excess oil.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2025
Resolution: Excess oil removed from bilges, all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2025
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. Port main engine shutdowns not operational at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2025
Resolution: Witnessed port main engine alarms and shutdowns, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 3 June 2025
Resolved
Each vessel must have a permanently exhibited, for the guidance of the master and crew members, general arrangement plans showing, for each deck, the various fire-retardant bulkheads together with particulars of the—(a) Fire-detection systems;(b) Manual-alarm systems;(c) Fire-extinguishing systems;(d) Fire doors;(e) Means
of ingress to the different compartments; and(f)
(f) Ventilating-systems, including the— (1) Positions of
he dampers;(2) Site of the emote means of stopping the
fans; and(3) Identification of the fans serving each section. Fire safety plan was not signed or stamped for coast guard approval IAW new construction requirements outlined in 127.110.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2025
Resolution: Walked fire plan. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2025
Resolved
Shapes shall be black and of the following sizes:(i) A ball shall have a diameter of not less than 0.6 meter.
The black circle dayshape was deformed and not useful for signalling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: Replaced damaged ball dayshape, all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2025
Resolved
The inspection for certification is made by a marine inspector to determine whether the vessel is in a safe and seaworthy condition. The owner or builder shall make the vessel and its equipment available for inspection. First aid kit found incomplete with expired supplies.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: First aid kit complete, all SAT.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 3 June 2025
Resolved
Each operation described in paragraphs (d), (e) and (f) of this section shall be fully recorded without delay in the Oil Record Book so that all the entries in the book appropriate to that operation are completed. Each completed operation shall be signed by the person or persons in charge of the operations concerned and each completed page shall be signed by the master or other person having charge of the ship. Oil record book entries were not complete or signed by vessel master. Crew was coached on proper proceedures for oil record book by marine inspector, and deficiency was cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 June 2025
Resolution: Crew was coached on proper proceedures for oil record book by marine inspector, and deficiency was cleared on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2024
Resolved
46 CFR 128.130(a)(7): Vital systems are those systems that are vital to a vessel's survivability and safety. Propulsion systems and their necessary auxiliaries and control systems are vital systems. STBD Main engine is out of service, due to a failure while sailing into Lambert's Point, Norfolk VA.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 September 2024
Resolution: Flywheel replaced on STBD Main Engine
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 15 February 2023
Resolved
Auxiliary steering must be controlled from a location that has communication with the bridge. Sound powered phone at the auxiliary steering controls in the engine room was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 17 February 2023
Resolution: Vessel provided report from 3rd party technician attesting to replacement and satisfactory test of the sound powered phone at the emergency steering station in the engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 December 2022
Resolved
Fuel oil samples are to be retained under the ship's control until the fuel oil is substantially consumed and for not less than 12 months; vessel was not maintaining fuel samples. Deficiency to remain open until next annual inspection to confirm maintaining of samples.
MARPOL 73/78 (11) VI/18.8.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 February 2023
Resolution: Verified vessel is maintaing fuel samples.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2022
Resolved
Transfer procedures must contain a line diagram of the vessel's transfer piping; transfer diagram was missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 12 July 2022
Resolved
Discharge of oil or oily mixtures into the sea from a ship is prohibited except after meeting specified conditions; vessel's OWS was inoperable due to "RTC malfunction" and could not meet requirements, rectify prior to using OWS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received servicing report.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 12 July 2022
Resolved
Inspector not limited in making inspections as he or she deems necessary to be assured of the safety of the vessel; washer, dryer, and two (02) refrigerators were unsecured, making vessel unsafe and not seaworthy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 July 2022
Resolved
Standby vessels must have one blanket for each person on the most populated facility that the standby vessel is designated to assist; vessel was 50 blankets short of requirement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2022
Resolved 9 August 2022
Resolution: Sufficient fire blankets purchased.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 July 2022
Resolved
Each vessel must minimize fire hazards, as far as reasonable and practicable; various lines on MDEs and generators had significant chaffing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 July 2022
Resolved
A rudder-angle indicator independent of the control of the main steering gear must be installed at the steering-control station in the pilothouse; stbd forward RAI was incapable of operating through the entire range of required movement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 30 August 2022
Resolution: Received field servicing report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2022
Resolved
Scope of annual inspection is the same as the inspection for certification in less detail. Scope of inspection for certification includes electrical installations; Phase A ground detector was missing a bulb.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2022
Resolved
Scope of annual inspection is the same as the inspection for certification in less detail. Scope of inspection for certification includes electrical installations; cover missing on Generator No. 2 light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022
Resolved
Each ring life buoy must be marked with Type I or II retro-reflective material; retro-reflective tape on multiple ring buoys was worn down.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022
Resolved
Each lifebuoy must be marked in block capital letters with the name of the OSV and the name of the port; multiple ring buoys have stenciling needing redone.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 July 2022
Resolved
Each vessel must carry adequate and up-to-date U.S. Coast Pilot; vessel had outdated Coast Pilot 4 and 5.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 15 August 2022
Resolution: Coast Pilots purchased.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 12 July 2022
Resolved
Each cable installation must meet IEEE 45-2002. Metallic cable supports must be placed not more than 24 inches apart; cable in engine room in back starboard portion was supported with plastic brackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 9 August 2022
Resolution: Received photo evidence of deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2020
Resolved
Vessel drydocked for emergency repairs and failed to notify Coast Guard. 46 CFR 126.140(b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 April 2020
Resolved 9 April 2020
Resolution: Issuing Letter of Warning in Lieu of Civil Penalty
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 April 2019
Resolved
Before any vessel leaves protected waters, the master shall ensure that the vessel's exposed cargo hatches & other openings in the hull are closed; made properly watertight by the use of gaskets; & properly secured for sea. Watertight door & escape hatch leading from engine room to the main deck need to be adjusted for watertight integrity. The gasket was for the escape hatch needs replaced due to a gash in material. 46 CFR 131.520; 17c.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 11 April 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2019
Resolved
Non-metallic flexible hose must be in accordance with SAE J-1942. Hoses for the fuel oil return on both PORT & STBD main engines were cracked & distorted; hose on STBD steering gear unit was cracked; & hoses for inlet & outlet for bow thruster oil tank were cracked. 46 CFR 56.60-25(b); 50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2019
Resolved 11 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 April 2019
Resolved
Each portable fire extinguisher must be inspected, maintained, & hydrostatically tested as required by NFPA 10, Chapter 4. Hoses on the portable CO2 extinguisher protecting the paint locker and the portable CO2 extinguisher located next to the STBD main engine were cracked. 46 CFR 132.350; 50 c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2019
Resolved 11 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2019
Resolved
Each battery used in an item of survival equipment & not clearly marked with an expiration date must be replaced during the annual inspection & repair. Batteries for floating waterlights had an expiration date of 2016. 46 CFR 131.575(e); 50c.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2019
Resolved 11 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 April 2019
Resolved
Lifebuoys fitted with bouyant line must have line that is twice the height of where it is stowed above the waterline or 30 meters (100 feet), whichever is greater. Line on both lifebuoys located on the 01 deck was 60 feet. 46 CFR 133.70(a)(4).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2019
Resolved 11 April 2019