Records from 2005 to 2021. Most recent: inspection, 8 March 2021.
Inspection history · 30
8 March 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7152440
7 October 2019
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6830249
13 June 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6737077
30 April 2019
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6673082
14 November 2018
DAPI Audit · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6580168
18 October 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6564121
1 March 2018
Administrative Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6364386
1 March 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6366534
3 December 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6326061
28 November 2017
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6314425
13 April 2017
Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6125619
7 September 2016
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5993962
19 April 2016
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5857702
19 April 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5859624
20 July 2015
Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5180503
15 August 2014
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4944012
6 January 2012
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4227333
17 September 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4148463
15 September 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4146472
9 September 2011
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4140523
23 August 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4125043
9 August 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4117714
12 August 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3291967
22 April 2008
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3190033
21 April 2008
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3189431
17 April 2008
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3186571
31 May 2007
Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2951824
8 May 2006
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2633488
17 May 2005
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2356044
28 January 2005
Plan Review "T" Boat · Construction Oversight · Simplified Stability Test
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2355645
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2019
Resolved
Employers must maintain records of chemical tests and provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Conduct DAPI Audit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Vessel operator maintains active drug/chemical testing program with Maritime Consortium.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Electrical equipment must be installed to protect from electrical hazards. Battery terminal has numerous unprotected ancillary wires. Properly remove and route these wires using distribution box to prevent potential shock or fire hazards.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Electrical wiring in compliance with the original electrical plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Each distribution panel and switchboard must be in as dry a location as practicable, adequately ventilated, and protected from falling debris and dripping or splashing water. Distribution panel cover is broken and exposed to weather.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: New distribution panel with cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Each battery must be located as high above fthe bilge as practicable, secured to protect against shifting with the roll and pitch. Battery box was not secured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Battery blocked and secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 October 2019
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Engine room and Aft aft bilge alarms are not operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: New visual and audible alarm installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Emergency fuel shutoff did not have labels.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Remote fuel shutoff switch properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2019
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved IAW 46 CFR 164.018. Ring life buoy is missing retroreflective tapes.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: New retroreflective tape installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Submersible electric bilge pump is permanently mounted. Submersible electric bilge pump float switch was not permanently fixed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Float switch permanently mounted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019
Resolved
The owner, managing opeator, or a qualified servicing facility as applicable must conduct following annual inspections and tests. Both portable and fixed fire fighting extinguishers were overdue for annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Annual servicing of fixed and portable extinguishers completed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019
Resolved
Portable fire extinguishers must be located so that they are clearly visible and reaily accessible from the space being protected and installed. Portable fire extinguisher was not mounted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Portable fire extinguisher was mounted and clearly indicated.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 October 2019
Resolved
Certificate of Documentation is required for the operation of a vessel. No COD onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: New COD onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2019
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Maintain written documentation and follow requirements per ASTM F-3099-19, Standard Practice for Parasailing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 5 December 2019
Resolution: Vessel has recommended procedures and documentation per Standard Practice for Parsailing.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 April 2019
Resolved
A VESSEL OF AT LEAST FIVE NET TONS WHICH ENGAGES IN THE FISHERIES ON THE NAVIGABLE WATERS OF THE UNITED STATES OR IN THE EXCLUSIVE ECONIMIC ZONE, OR COASTWISE TRADE, UNLESS EXEMPT UNDER 67.9(C), MUST HAVE A CERTIFICATE OF DOCUMENTATION BEARING A VALID ENDORSEMENT APPROPRIATE FOR THE ACTIVITY IN WHICH ENGAGED; VESSEL DOES NOT HAVE A VALID COD. PROVIDE VALID COD. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2019
Resolution: Vessel rep received new COD
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 October 2018
Resolved
Remote fuel shutoff valve for port fuel tank does not work. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Replaced with new valves. Tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 October 2018
Resolved
Missing flame shield. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2018
Resolution: Installed a flame shield.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2018
Resolved
Conduct DAPI Audit. Employers must maintain records of chemical tests and provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 November 2018
Resolution: Completed satisfactory DAPI Audit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 October 2018
Resolved
Provide proof of pre-employment chemical testing of crew. o marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 November 2018
Resolved 25 October 2018
Resolution: Company in compliance with pre-employment chemical testing requirement.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 18 October 2018
Resolved
No crew members have a valid CPR certification. 50% of crew shall have Red Cross First Aid /CPR certification per NVIC 1-91. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2018
Resolution: Licensed crew member has a valid CPR certification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2018
Resolved
Raw water intake hose to sea strainer bent and not double clamped. Nonmetallic hose may be use for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat , has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Replaced hose with double clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2018
Resolved
All hull valves would not open or close. A positive shutoff valve is installed at the hull penetration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Replaced with new valves and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2018
Resolved
Raw water exit hose from sea strainer is loose and second clamp is not over the spool piece. Nonmetallic hose may be use for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat , has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: REnewed with new hose and double clamped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 October 2018
Resolved
Port diesel fuel filler hose connection is lossely attached to nonmetallic hose to fuel tank. Hose must overlap metallic pipe ends at the least 1 1/2 times the pipe diameter and must be secured at each end by clamps. The flexible section must be accessible and as near the upper end of the fill pipe as practicable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Renewed with new hose and double clamped.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 October 2018
Resolved
No visual indication on both bilge high level alarms. A visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned spaces.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 October 2018
Resolution: Both visual alarms tested satifactorily.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2018
Resolved
Fixed F/F alarm panel is not attached to steering console. System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Fixed FF alarm panel proeprly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018
Resolved
No vessel name on one child PFD. Each life jacket must be marked in clearly legible block capital letters with the vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Vessel name stenciled on the child PFD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 October 2018
Resolved
No vessel name on the ring life buoy. Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Vessel name stenciled on the ring life buoy.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 October 2018
Resolved
Emergency broadcast placard not posted. A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Emergency radio procedures posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2018
Resolved
No signage for child life jacket. Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2018
Resolution: Sign posted.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 October 2018
Resolved
Provide annual certification for paasail harness, passenger bars, and canopies. arasail harness, passenger bars, and canopies shall be sent to the manufacturer every year to be overhauled and inspected. The manufacturer shall provide a letter or certification of the equipments inspection and endorsement per ASTM F3099 17a.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 October 2018
Resolution: Provided internal inspection of parasail equipment.
Navigation › Piloting/Steering › Marine Charts
Issued 7 September 2016
Resolved
provide up to date chart for applicable area of operation.
Condition: Invalid
Due 14 September 2016
Resolved 9 September 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 September 2016
Resolved
Replace retroreflective tape on identified child lifejackets and 01 adult lifejacket.
Condition: Invalid
Due 14 September 2016
Resolved 9 September 2016
Lifesaving › Buoyant Apparatus › Serviceable
Issued 7 September 2016
Resolved
Replace worn lifering and associated line.
Condition: Invalid
Due 14 September 2016
Resolved 9 September 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 September 2016
Resolved
properly re-label lifejacket stowage area
Condition: Damaged By Earlier Event
Due 14 September 2016
Resolved 9 September 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2016
Resolved
Replace expired contents in first aid kit.
Condition: Invalid
Due 14 September 2016
Resolved 9 September 2016
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 September 2016
Resolved
Properly seal bulkhead penetrations in machinery space. Prior to sealing, provide CG marine inspectors with sealant product information.
Condition: Invalid
Due 14 September 2016
Resolved 9 September 2016
Resolution: Verified sealant was fire block, made by 3M.
Electrical › Electric Supply System (service) › Cable
Issued 7 September 2016
Resolved
replace melted ground-side cable on port battery.
Condition: Invalid
Due 14 September 2016
Resolved 8 September 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 September 2016
Resolved
demonstrate proper operation of starboard and anchor light
Due 14 September 2016
Resolved 17 September 2016
Resolution: Purchased new nav lights.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 September 2016
Resolved
replace non-marine wire and secure open connections in navigation console
Condition: Invalid
Due 21 September 2016
Resolved 9 September 2016
Documentation › Logs/Records › Drug Test Records
Issued 7 September 2016
Resolved
Provide most current list of drug and alcohol program enrolled employees.
Due 21 September 2016
Resolved 15 September 2016
Resolution: Most current list provided by employer. DAPI AUDIT also conducted and remains outstanding.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 April 2016
Resolved
Vessel's main engine overheated and had to be shut down manually and cooled prior to operation. Repairs shall be made in kind. Any alteration of the equipment must be approved by [name withheld] repairs are made, and prior to carrying passengers, vessel shall demonstrate proper operation of main engine to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2016
Resolved 24 May 2016
Resolution: Vessel installed new main propulsion engine; an inspection of installation and sea trials was perfromed; all sat.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 19 April 2016
Resolved
Vessel's RPM gauge is not functioning; provide a properly operating RPM gauge.
Condition: Improper Installation
Due 30 May 2016
Resolved 29 November 2017
Resolution: Found no issues with RPM gauge at COI inspection
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 August 2014
Resolved
Provide lifeline per 46 CFR 180.70 (c)
Due 12 September 2014
Resolved 12 December 2014
Resolution: Replaced yellow line with a black line.
Navigation › Piloting/Steering › Marine Charts
Issued 15 August 2014
Resolved
Provide current and corrected chart.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2014
Resolution: Vessel provided a new chart for Honolulu harbor.
Engineering › Thrusters › Motor
Issued 15 August 2014
Resolved
Prove proper operation of bow thruster by next drydock.
Action required: 705 - Other - as specified
Resolved 29 April 2015
Resolution: Removed inop thruster and made watertight.
Operations/Management › Drills/Instruction › Fire
Issued 9 September 2011
Resolved
Log fire and man overboard drills.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 15 September 2011
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 September 2011
Resolved
Provide company drug testing policy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 6 January 2012
Resolution: Cleared deficiency as per DAPI audit conducted on 06JAN12 by [name withheld]
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 9 September 2011
Resolved
Provide proof of pre-employement drug testing background checks.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 6 January 2012
Resolution: Cleared deficiency as per DAPI audit conducted on 06JAN12 by [name withheld]
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 9 September 2011
Resolved
Provide arrangements of reasonable cause testing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 6 January 2012
Resolution: Cleared deficiency as per DAPI audit conducted on 06JAN12 by [name withheld]
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 9 September 2011
Resolved
Provide arrangements for post-casualty testing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 6 January 2012
Resolution: Cleared deficiency as per DAPI audit conducted on 06JAN12 by [name withheld]
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 9 September 2011
Resolved
Provide alcohol testing devices.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 6 January 2012
Resolution: Cleared deficiency as per DAPI audit conducted on 06JAN12 by [name withheld]
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 September 2011
Resolved
EAP requirements: Provide EAP, hotline number, (1) hour supervisor EAP training, name and contact information for substance abuse professional.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 6 January 2012
Resolution: Cleared deficiency as per DAPI audit conducted on 06JAN12 by [name withheld]
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 9 September 2011
Resolved
Provide valid CPR card for 50% of crew.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 15 September 2011
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 9 September 2011
Resolved
Provide log entries for lifesaving equipment.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2011
Resolved 15 September 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 12 August 2008
Resolved
Main propulsion engine failed to start. Demonstrate proper operations of starting MDE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2008
Resolution: Replaced starter. Problem corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 August 2008
Resolved
Automatic shutdown of MDE and override of Fireboy system does not work properly. Demonstrate proper operation.
Condition: Unknown
Due 26 August 2008
Resolved 14 August 2008
Resolution: Fireboy MDE shutdown and override system repaired. Tested SAT. Problem corrected.
Lifesaving › Hand Flares › Storage
Issued 12 August 2008
Resolved
Emergency signals (flares) stored incorrectly. Provide proper container.
Condition: Placed in Improper Service
Due 19 August 2008
Resolved 13 August 2008
Resolution: Purchased proper container. Problem corrected.