Records from 2006 to 2020. Most recent: inspection, 30 October 2020.
Inspection history · 15
30 October 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087399
23 May 2014
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4866654
10 May 2012
Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4308071
6 January 2012
DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4227331
23 September 2011
COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4152745
17 September 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4148463
30 November 2010
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3901727
22 September 2010
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3855293
21 January 2010
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3667802
17 December 2009
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3650337
2 January 2009
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3386684
25 September 2008
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3332751
19 November 2007
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3101014
2 October 2006
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2792110
1 February 2006
Hull Examination · Construction Oversight · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2577220
Lifesaving › Lifebuoys › Serviceable
Issued 23 September 2011
Resolved
Renew battery on ring buoy water light
Due 23 October 2011
Resolved 14 October 2011
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 23 September 2011
Resolved
Provide cover for battery box on stbd side engine room.
Due 23 October 2011
Resolved 14 October 2011
Construction/Loadline › Hull › Weld
Issued 22 September 2010
Resolved
Grind and reweld all identified weld cracks in second, third, and fuel tank compartments.
Action required: 705 - Other - as specified
Resolved 30 September 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 September 2010
Resolved
Crop and renew pitted area of stbd longitudinal stringer in fuel tank compartment.
Action required: 705 - Other - as specified
Resolved 30 September 2010
Resolution: Two pits clad welded. In addition, a CG inspection of the area every six months after the COI anniversary.
Electrical › Electric Supply System (service) › Cable
Issued 22 September 2010
Resolved
Remove dead end wires in engine room and fuel tank spaces and cover all exposed electrical connections to make them ignition protected.
Action required: 705 - Other - as specified
Due 6 October 2010
Resolved 30 September 2010
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 17 December 2009
Resolved
Inadequate number of distress signals found onboard. Provide adequate number in accordance with 46 CFR 180.68(a).
Action required: 705 - Other - as specified
Resolved 17 December 2009
Resolution: Verified to the satisfaction of attending marine inspector.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 December 2009
Resolved
Renew emergency broadcast placard due to excessive fading IAW 46 CFR 184.506.
Due 17 January 2010
Resolved 17 December 2009
Resolution: Verified presence of renewed placard IAW with applicable regulatons.
Lifesaving › Lifebuoys › Serviceable
Issued 17 December 2009
Resolved
Ring life buoy line found frayed. Renew ring life buoy line in accordance with 46 CFR 180.70 (b)(1).
Due 17 January 2010
Resolved 17 December 2009
Resolution: Verified condition of renewed ring life buoy and storage IAW with applicable regulations.
Fire Fighting › Fire Bucket › Lanyard
Issued 17 December 2009
Resolved
Provide lanyard for fire bucket IAW 46 CFR 181.610
Due 17 January 2010
Resolved 21 January 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 December 2009
Resolved
Twenty-seven adult PFD's found unserviceable. Renew same prior to carrying passengers IAW 46 CFR 180.71 (a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2009
Resolution: Verified that twenty-seven renewed PFD''''s were being carried onboard IAW with applicable regulations.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 December 2009
Resolved
PMS snaps for PFD storage. Evidence of corrosion cited caused by dissimilar metals.
Due 17 January 2010
Resolved 21 January 2010
Resolution: Addressed to the satisfaction of attending marine inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure Gauge
Issued 2 January 2009
Resolved
Provide B-I fire extinguisher for operating station.
Action required: 705 - Other - as specified
Resolved 2 January 2009
Resolution: Provided new B-I fire extinguisher.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 2 January 2009
Resolved
Prove proper operation of automatic shutdown of engines and override associated with pre-engineered fixed fire system.
Action required: 705 - Other - as specified
Resolved 2 January 2009
Resolution: Replaced fire fire system control box and proved proper operation of shut down and engine override.
Communications › Radio Communications › EPIRB
Issued 2 January 2009
Resolved
Provide new hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Resolved 2 January 2009
Resolution: Provided new EPIRB hydrostatic release.
Communications › Radio Communications › EPIRB
Issued 2 January 2009
Resolved
Provide proof of current EPIRB registration.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 8 January 2009
Resolution: Provided proof of current EPIRB registration.
Operations/Management › Drills/Instruction › Fire
Issued 30 December 2008
Resolved
Complete fire and man overboard drills.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 8 January 2009
Resolution: Conducted satisfactory drill.
Engineering › Fuel Oil Service System › Piping
Issued 25 September 2008
Resolved
fuel pipes from fuel tank to main diesel engines are watsed. Replace with original.
Action required: 705 - Other - as specified
Resolved 26 September 2008
Resolution: replaced two 6 inch fuel pipes
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 25 September 2008
Resolved
Demonstrated operation of port engine through hull valve
Action required: 705 - Other - as specified
Resolved 26 September 2008
Resolution: A new port through hull valve was installed and satisfactory operated.
Electrical › Electric Generation Source (service) › Generator
Issued 25 September 2008
Resolved
Aft mounting bolt on port MDE is missing. Reinstall as original.
Action required: 705 - Other - as specified
Resolved 26 September 2008
Resolution: Bolt was reinstalled
Construction/Loadline › Structures › Ventilators
Issued 25 September 2008
Resolved
Demonstrat proper operation of all engine room ventilation closures.
Action required: 705 - Other - as specified
Resolved 26 September 2008
Resolution: Hinges and levers were cleaned and lubricated and the ventilation luvers closed easily.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 November 2007
Resolved
Provide an audible alarm to indicate when installed fixed gas fire extinguishing system is discharged IAW 46 CFR 181.420
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 10 December 2007
Resolution: Audible alarm installed in system. Test sat.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 19 November 2007
Resolved
Provide an emergency instruction list and post it on the vessel IAW 46 CFR 185.510 and 46 CFR 185.512
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 10 December 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 19 November 2007
Resolved
Provide a valid marine radio operator permit
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 27 November 2007
Resolution: Received fax of temporary marine operator permit.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 November 2007
Resolved
Provide a current FCC Safety Certificate for the vessel
Due 28 November 2007
Resolved 28 November 2007
Resolution: Original docuemnt provided at the end of examination.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 November 2007
Resolved
Provide a current first aid/CPR card for 50% of crew.
Action required: 705 - Other - as specified
Due 28 November 2007
Resolved 27 November 2007
Resolution: Received fax for 1 CPR/First aid card
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 October 2006
Resolved
Fuel oil cut-off valve is located in the fuel tank compartment and requires a 22" reach to operate. Provide arrangement for remote fuel shutoff valve(s) so that the reach into the fuel tank space to operate the valve(s) is no more than 12". 46CFR 182.455(b)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2006
Resolved 5 October 2006
Resolution: Operator installed pull-ring and wire arrangement with pull-ring now located withing two inches of access to the fuel tank space.
Lifesaving › Hand Flares › Storage
Issued 2 October 2006
Resolved
Hand flares and smoke signals were not properly stowed. Provide waterproof container for pyrotechnics. Mark "DISTRESS SIGNALS" IAW 46CFR 180.68 and 185.614.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2006
Resolved 5 October 2006
Resolution: Prover container provided and marked.
Lifesaving › Lifefloat › Float Free
Issued 2 October 2006
Resolved
Lifefloats are installed with covers and bungee cords that would prevent free deployment in event of a sinking. Provide proper stowage for (2) lifefloats so they will float free if vessel sinks. 46 CFR 180.130. Note: Alternately life floats may be removed as long as the vesssel carries a properly registered EPIRB and restricts route to no more than 3NM from shore IAW 46 CFR Table 180.200(c).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2006
Resolved 5 October 2006
Resolution: EPIRB registered. Route is no more than 3NM from shore (warm water). Life floats removed from vessel.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 February 2006
Resolved
Prove proper operation of VHF radio.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: Proper operation of radio demonstrated.
Documentation › Certificates/Documents › FCC SSL
Issued 1 February 2006
Resolved
Provide FCC SSL, Radio Safety Certificate & Radio op permit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: Sighted Safety Radio Certificate and Temporary Station license.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2006
Resolved
Conduct new to zone inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: New to Zone inspection completed. Cleared all outstanding CG-835s.
Navigation › Piloting/Steering › Marine Charts
Issued 1 February 2006
Resolved
Provide navigation publications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2006
Resolution: Publications provided.
Communications › Radio Communications › EPIRB
Issued 1 February 2006
Resolved
Provide EPIRB Registration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: Sighted on-line receipt from NOAA for EPIRB registration.
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 February 2006
Resolved
Conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2006
Resolution: Conducted satisfactory drills.