Records from 2005 to 2026. Most recent: inspection, 20 May 2026.
Inspection history · 30
20 May 2026
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8376893
5 March 2025
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8089005
10 December 2024
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8045899
26 September 2024
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8010079
21 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7916866
18 July 2023
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7746819
27 April 2023
Simplified Stability Test · Hull Examination · Examination of Repairs · Administrative Inspection · Special
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7676735
19 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7454549
14 July 2021
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7292370
26 April 2021
Deficiency Check · Drydock Exam · Annual Inspection · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7185742
5 May 2020
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6948304
9 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6680957
4 April 2019
Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6655507
2 May 2018
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6441698
1 May 2017
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6207117
11 April 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6115494
2 May 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5825920
22 May 2014
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4865584
8 May 2014
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4863406
4 June 2012
Plan Review "T" Boat
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4336185
7 May 2012
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4314174
15 July 2011
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4082647
12 May 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3547964
6 April 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3447531
27 February 2009
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3426404
15 May 2008
MARPOL Annex V Examination · Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3226257
10 May 2007
Deficiency Check · MARPOL Annex V Examination · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3094197
23 February 2007
Hull Examination · Internal Structural Exam · Construction Oversight
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2877977
10 May 2006
MARPOL Annex V Examination · Deficiency Check · Plan Review "T" Boat · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2680798
27 April 2005
Construction Oversight · Deadweight Survey · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2347564
Engineering › Fuel Oil Service System › Piping
Issued 2 May 2018
Resolved
Provide proper flexible fuel hose on diesel fuel line going to fuel/water separator on port and stbd engines. Existing fuel line is not sufficient.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 11 May 2018
Resolution: Installed closing valves and caped ends off.
Engineering › Bilge Water Management System › Hose
Issued 1 May 2017
Resolved
A portable hand bilge pump suction hose must be capable of reaching the bilge of each watertight compartment. Hose too short.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Adequate length of hose is now onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2017
Resolved
A vessel must carry either a first-aid kit approved under 46CFR160.041 or kit w/equivalent contents. Meds expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Expired medication has been replaced.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 1 May 2017
Resolved
A vessel must carry up-to-date current tables. Current tables were dated 2011.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 31 May 2017
Resolution: Updated current tables are now onboard.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 May 2016
Resolved
Update FCC Safety Certificate with current call sign
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: FCC certificate updated
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 2 May 2016
Resolved
Provide pre-employment drug test results
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2016
Resolution: test results provided
Navigation › Piloting/Steering › Marine Charts
Issued 2 May 2016
Resolved
Provide updated charts and publications
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2016
Resolved 26 May 2016
Resolution: Current charts and pubs onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 May 2014
Resolved
Provide approved battery for water light.
Action required: 705 - Other - as specified
Resolved 22 May 2014
Resolution: Witnessed approved battery for waterlight. Def Cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 7 May 2012
Resolved
Fire Extinguisher needs to be mounted with an approved bracket
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 21 May 2012
Resolution: Extinguisher mounted with approved bracket.
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 May 2012
Resolved
Install Compass to illuminate as per 46 cfr 184.02 (c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 21 May 2012
Resolution: Wire compass to illuminate
Navigation › Piloting/Steering › Marine Charts
Issued 7 May 2012
Resolved
Provide curent copy of marine charts of operating area.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 21 May 2012
Resolution: Provided updated charts of operating area.
Documentation › Certificates/Documents › FCC SSL
Issued 12 May 2009
Resolved
Provide FCC safety certificate
Action required: 705 - Other - as specified
Due 12 June 2009
Resolved 14 May 2009
Resolution: FCC safety Certificate provided
Fire Fighting › Fire Bucket › Quantity
Issued 12 May 2009
Resolved
Provide 3ea fire buckets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2009
Resolution: O/O provided 3ea fire buckets
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2009
Resolved
Install railing cable across bow
Action required: 705 - Other - as specified
Due 19 May 2009
Resolved 14 May 2009
Resolution: Railing installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 May 2009
Resolved
Post COI, Stability letter, Emergency Instructions
Action required: 705 - Other - as specified
Due 12 June 2009
Resolved 14 May 2009
Resolution: All documents posted
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 May 2009
Resolved
Provide fixed fire extinguisher serving certificate for fixed firefighting
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2009
Resolution: Servicing certificate provided
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 February 2009
Resolved
Make vessel available for Drydock and internal Structural exam IAW 46CFR 176.600 prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2009
Resolution: Vessel completed credit DDX and ISE.
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 10 May 2007
Resolved
Provide copy of approved fixed fire fighting plan.
Due 10 June 2007
Resolved 14 April 2008
Resolution: The new construction file contains a copy of the approved fixed fire-fighting plan. This requirement was written before the vessel file arrived to the sector.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 May 2007
Resolved
Provide FCC Safety Certificate.
Due 10 June 2007
Resolved 16 May 2007
Resolution: The FCC ticket was shown to P.O. Mooers.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 May 2007
Resolved
Service fixed and portable fire extinguishers by a qualified servicing facility.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2007
Resolution: A copy of the servicing report was shown to P.O. Moores.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 May 2007
Resolved
Provide training, bridge, and lifesaving equipment log.
Due 10 June 2007
Resolved 16 May 2007
Resolution: P.O. Mooers viewed the logs.
Communications › Radio Communications › EPIRB
Issued 10 May 2007
Resolved
Provide hydrostatic release for EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2007
Resolution: A hydrostatic release was installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 May 2007
Resolved
Provide Emergency broadcast placard
Due 10 June 2007
Resolved 16 May 2007
Resolution: P.O. Mooers observed an emergency broadcast placard.
Stability › Unintentional Flooding › General
Issued 10 May 2007
Resolved
Provide original stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2007
Resolution: O/O provided the original stability lettter.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 May 2007
Resolved
Provide satisfactory man overboard drill w/harness and life jacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2007
Resolution: A satisfacory man overboard drill was conducted.
Stability › Severe Wind/Roll › General
Issued 10 May 2007
Resolved
Remove canvass in way of weather deck or prove no effect on stability.
Due 10 June 2007
Resolved 16 May 2007
Resolution: O/O provided intact stability evaluation report that shows the canvassed are was taken into account for wind heel.
Stability › Unintentional Flooding › General
Issued 10 May 2007
Resolved
Attach capture chain to hatch stbd side fwd of engine room.
Due 10 June 2007
Resolved 16 May 2007
Resolution: A capture chain was attached.
Fire Fighting › Structural Fire Protection - General › Hull Construction
Issued 10 May 2007
Resolved
Make forward bulkhead of engine room fume tight.
Due 10 June 2007
Resolved 16 May 2007
Resolution: The bulkhead was made fume tight.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 May 2006
Resolved
Provide written documentation proving weight of new engines and weight of old engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2006
Resolution: Documentation in file, sat.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 10 May 2006
Resolved
Provide drawing of newly installed raw water piping including materials list.
Action required: 705 - Other - as specified
Resolved 22 May 2006
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 10 May 2006
Resolved
Provide drawing of modified engine exhaust system.
Action required: 705 - Other - as specified
Resolved 22 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 10 May 2006
Resolved
Provide drawing of modified engine mounts.
Action required: 705 - Other - as specified
Resolved 22 May 2006
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 10 May 2006
Resolved
Provide description of controls for new engines.
Action required: 705 - Other - as specified
Resolved 22 May 2006
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 May 2006
Resolved
Make vessel available for sesa trials
Action required: 705 - Other - as specified
Resolved 22 May 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 10 May 2006
Resolved
Provide drawings of new air intakes. Include description of materials.
Action required: 705 - Other - as specified
Resolved 22 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 April 2005
Resolved
Post lifejacket donning placard.
Due 27 May 2005
Resolved 19 May 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 27 April 2005
Resolved
Provide FCC station and Radiotelephony certificates.
Due 27 May 2005
Resolved 19 May 2005
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 27 April 2005
Resolved
Prove enrollment in approved random drug testing program.
Due 27 May 2005
Resolved 19 May 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 April 2005
Resolved
Provide all nautical pubs and charts as required.
Due 27 May 2005
Resolved 19 May 2005
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 27 April 2005
Resolved
Post deviation table.
Due 27 May 2005
Resolved 19 May 2005
Fire Fighting › Fire Bucket › Availability
Issued 27 April 2005
Resolved
Add 3 fire buckets labeled and w/ lanyards.
Due 27 May 2005
Resolved 19 May 2005
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 April 2005
Resolved
Conduct fire and man overboard drills.
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 19 May 2005