Records from 2011 to 2024. Most recent: inspection, 3 June 2024.
Inspection history · 14
3 June 2024
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7921623
18 April 2024
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7897777
25 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7776800
22 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7540862
17 August 2021
Internal Structural Exam · Deficiency Check · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7289516
28 September 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7067661
10 August 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7029417
4 October 2018
Initial Certification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6554956
19 March 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4819664
6 September 2012
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4497252
14 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4244035
3 August 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4104441
3 August 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4112448
31 July 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4103260
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2024
Resolved
Fire pump is required to delivery 50PSI at a flow rate
of 80 gallons a minute. Fire pump onboard is only
meeting 35 PSI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 7 June 2024
Resolution: Portable pump onboard that meets the regulation. Vsl will continue repairing fixed pump.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 June 2024
Resolved
Coastwise vessel is required 6 day and 6 night flares.
Vsl could also have 12 night flares. All flares need be
stored in a portable watertight container of a bright
color clearly label "DISTRESS SIGNALS". Vessel only has
9 flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 7 June 2024
Resolution: Vsl has required flares onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 3 June 2024
Resolved
Vsl is required 4 line throwing appliances per 46 CFR
160.040 and auxiliary line per 46 CFR 141.385. Vsl only
has 1 line throwing device on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2024
Resolved 7 June 2024
Resolution: Vsl has required line throwing appliances onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 June 2024
Resolved
EPRIB must be float free if the towing vessel sinks.
Hydrostatic release is expired and needs replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 7 June 2024
Resolution: Current hydro static release installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2024
Resolved
Main Engine overboard discharges shall have suitable
hanger. Currently they are held with zip ties.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 7 June 2024
Resolution: Metal hangers are installed to support OVB exhaust discharge.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 3 June 2024
Resolved
Windows and other openings at the operating station must
be of sufficient size and properly located to provide a
clear field of vision. Port window has debris that
cannot be removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2024
Resolved 7 June 2024
Resolution: Vessel has installed in glass window.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 August 2022
Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of § 199.190 of this chapter, as applicable, and the vessel's TSMS, if the vessel has a TSMS.
Each inflatable lifesaving appliance and marine evacuation system must be serviced within 12 months of its initial packing; and within 12 months of each subsequent servicing, except when servicing is delayed until the next scheduled inspection of the vessel, provided the delay does not exceed 5 months.
Liferaft must be serviced prior to operations.
46CFR141.235(a) --> 46CFR199.190(g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2022
Resolved 29 August 2022
Resolution: Life raft serviced
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 August 2022
Resolved
Employer should be able to conduct an alcohol test after a casualty or incident.
Alcohol test strips are expired.
46CFR4.06-3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 29 August 2022
Resolution: Operator emailed photographs of new box of alcohol test strips.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 22 August 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: automatic, battery-operated with a duration of no less than 2 hours; or non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power.
There is no emergency lighting in berthing area.
46CFR143.410(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 23 August 2022
Resolution: Operator emailed photograph of exit sign and phosphorescent tape applied to the interior of berthing door.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 31 August 2021
Resolved
General Alarms: in E/R & any other area where background noise makes alarm hard to hear, a supplemental flashing red light shall be installed. Light in E/R was not working; replace. 46 CFR 142.235(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2021
Resolution: Completed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 August 2021
Resolved
Vessel in Coastwise service beyond 3nm is req'd 6 day & 6 night distress signals. Vessel had 7 up to date and 6 expired flares. Provide updated flares to meet 6 day & 6 night reqmt. This was corrected on the spot by purchase of new flares prior to inspection completion.
Action required: 10 - Deficiency Rectified
Resolved 31 August 2021
Resolution: completed on the spot
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 September 2020
Resolved
Each towing vessel shall have a fire pump capable of delivering a flow of 80 gmp. Fixed fire pump inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 September 2020
Resolved
Each towing vessel must be fitted with a general alarm that: (3) has installed flashing red light. Light broke.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 September 2020
Resolved
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Lifebuoys must be at least 610 millimeters (24 inches) in diameter. (2) At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. Vessel life buoy required retro-reflective material, proper life light battery, life light battery installation date, water light lanyard must be at least
three feet in length and secured with proper clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2020
Resolved
The Safety and Health Plan shall be readily available aboard the towing vessel and may be a standalone document or incorporated into the TSMS. Vessel health and safety plan not found aboard vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 September 2020
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel was found without Bridge to Bridge radiography certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2020
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel shall maintain necessary testing equipment. Vessel records were not maintained and vessel's testing equipment expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2020
Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Emergency exit in machinery space not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2020
Resolved
The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. Vessel fire hose compromised during operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2020
Resolved 9 October 2020
Resolution: Vessel was prepared for inspection, marine inspectors witnessed satisfactory rectification of item