Records from 2006 to 2026. Most recent: inspection, 30 January 2026.
Inspection history · 19
30 January 2026
Examination of Repairs · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8304181
15 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8112234
12 June 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7933481
27 March 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7657680
16 February 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7637773
2 May 2022
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7442440
28 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7420293
28 September 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7067318
16 September 2020
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7059339
5 February 2015
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5068056
1 August 2014
Administration
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4940861
31 July 2014
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4943992
20 November 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4756177
27 February 2013
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4541948
11 January 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4514749
11 January 2013
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4528760
17 September 2010
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3851980
2 November 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2813246
20 April 2006
Uninspected Other
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2629010
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 June 2024
Resolved
The following system must be equipped with gauges at the machinery location: Auxiliary generator engine RPM. The #1 and #2 generators were not equipped with RPM gauges.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 31 July 2024
Resolution: Received cert for RPM gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 March 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. [prt R/G inner and outer mounting brackets cracked.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2023
Resolved 29 March 2023
Resolution: Welder repaired cracked engine mounts. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 27 March 2023
Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation:
(a) Fathometer (except Western Rivers). Fathometer not installed.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 19 April 2023
Resolution: Fathometer installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 March 2023
Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods: No ballast management plan.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2023
Resolved 4 April 2023
Resolution: Ballast water management plan submitted and reviewed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 March 2023
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: No emergency lighting in crew accomidations.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 28 March 2023
Resolution: Emergency lighting replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 May 2022
Resolved
THE MASTER MUST ENSURE THAT ALL HATCHES, DOORS, AND OTHER OPENINGS DESIGNED TO BE WATERIGHT OR WEATHER-TIGHT FUNCTION PROPERLY. IDENTIFIED INSUFICIENT GASKETS ON WATERTIGHT DOORS.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 26 May 2022
Resolution: Replaced gasket on watertight door.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 May 2022
Resolved
AN EXPOSED HAZARD SUCH AS GEARS AND ROTATING MACHINERY, MUST BE PROTECTED BY A COVER, GUARD, OR RAIL. IDENTIFIED ROTATING MACHINERY WITHOUT GUARD.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 26 May 2022
Resolution: Installed guard in front of moving machinery.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 19 May 2022
Resolved
NAME OF VESSEL MUST BE MARKED ON SOME CLEARLY VISIBLE EXTERIOR PART OF THE PORT AND STARBOARD BOW. IDENTIFIED INCORRECT NAME OF VESSEL ON PORT AND STARBOARD BOW.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 26 May 2022
Resolution: Installed sign with correct vessel name on port and starboard sides of vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 March 2022
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection prior to operation.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2022
Resolved 26 May 2022
Resolution: COI Issued
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 33% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2021
Resolved 22 March 2021
Resolution: Vessel Passed COI Inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2020
Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. one floating light had a cracked housing case. Repair or replace, demonstrating proper operation to the satisfaction of attending CG Inspector prior to operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 September 2020
Resolution: Replaced floating light
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 September 2020
Resolved
Towing vessels with a Towing Safety Management Systems (TSMS) must be operated in accordance with the TSMS applicable to the vessel. Vessel was operating without a licensed master, lacked any documentation of satisfactory demonstration of crew training, and lacked crew orientation or training on the Health and Safety Plan. Provide Licensed Master prior to vessel operations.
Action required: 10 - Deficiency Rectified
Resolved 29 September 2020
Resolution: Vessel received licensed master, health and safety plan, and crew traing.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 28 September 2020
Resolved
Each towing vessel must carry the survival craft specified in Table 141.305 of this section, as appropriate for the the towing vessel. Vessel was operating on a Lake, Bays, Sound route without a buoyant apparatus. Outfit vessel with proper lifesaving equipment for route that the vessel is working prior to operations.
Action required: 10 - Deficiency Rectified
Resolved 29 September 2020
Resolution: Vessel received inflatable liferaft
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 September 2020
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Properly pump excess oily-water and clean bilge prior to operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 September 2020
Resolution: Bilges clean and free of oil.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2020
Resolved
Inspection and testing. All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section, or more frequently if otherwise required by the TSMS applicable to the vessel. Annual testing of Fire Detection Panel not complete. Provide satisfactory evidence of completion of servicing prior to operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 September 2020
Resolution: Provided evidence of annual testing.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 September 2020
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. Fixed fire pump could not supply adequate pressure and flow to system. Repair or demonstrate proper operation of portable fire pump to satisfaction of attending CG Inspector prior to operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 September 2020
Resolution: Vessel received self priming fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 September 2020
Resolved
Each towing vessel must have a reliable means to provide
notification when an emergency condition exists or an essential system develops problems that require attention. Port and Starboard gauge panels in engine room and operating station were inoperable and had frayed wires coming from the panel. Repair or replace, demonstrating proper operation to the satisfaction of attending CG Inspector prior to operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2020
Resolved 22 March 2021
Resolution: Passed COI Inspection
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 28 September 2020
Resolved
Towing vessels must be equipped with a fathometer as applicable to the area of operation. Install fathometer on vessel prior to 31OCT2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2020
Resolved 22 March 2021
Resolution: Passed COI Inspection
Electrical › Electric Generation Source (service) › Power Requirement
Issued 11 January 2013
Resolved
Vsl collided with in tow barge due to loss of power in pilot house. Vsl to remain at anchored MM 81 until power is restored and tech report provided to local OCMI.
Action required: 705 - Other - as specified
Due 12 January 2013
Resolved 12 January 2013
Resolution: Tech report provided by Lafayette Work Boat Rentals certifying repair and proper operations of pilot house power. ALL SAT