Records from 1997 to 2019. Most recent: inspection, 26 August 2019.
Inspection history · 16
26 August 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6794819
1 July 2014
MTSA Verification · Deficiency Check · Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4907261
29 June 2011
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4071727
22 February 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3951420
30 September 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3860980
11 January 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3402210
7 November 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3097615
10 May 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2927378
27 November 2006
MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2829293
9 July 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2229700
24 May 2004
Type not recorded
No type recorded · USCGC PENOBSCOT BAY (WTGB 107) · USCG Northeast District (CGD-NE) · Activity 2083748
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973037
24 July 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 228493
16 October 1997
Uninspected Towing Vessel · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1111273
8 January 1997
MARPOL Annex V Examination · Damage Survey · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1439810
7 January 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 102285
Construction/Loadline
Issued 8 January 1997
Resolved
Repair starboard side aft bitt area and bullwark and upper deck area to thesatisfaction of the marine inspector. COTP_x001C_
Condition: Unknown
Due 7 February 1997
Resolved 13 January 1997
Accommodation/Occupational Safety
Issued 8 January 1997
Resolved
Correct MSD so it will not pump directly overboard. COTP_x001C_
Condition: Unknown
Due 7 February 1997
Resolved 13 January 1997
Navigation
Issued 8 January 1997
Resolved
Make port light watertight, presently there is water inside._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 January 1997
Resolved
Remove battery charger from engine room._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 8 January 1997
Resolved
Investigate vibration at 3/4 power. (Recommendation)_x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 January 1997
Resolved
Replace missing guard on port MG set._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 January 1997
Resolved
Cover exposed wiring for motor control for reefer units._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 8 January 1997
Resolved
Properly secure the water bypass cooling hose._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 January 1997
Resolved
Provide cover on battery on port side engine room._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 January 1997
Resolved
Provide guards for fan to reefer unit._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 January 1997
Resolved
Clean shore power transformer cover, presently covered with grease._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 8 January 1997
Resolved
Provide non-conductive mat in front of switch board. (Recommendation)_x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 8 January 1997
Resolved
Replace missing compass light._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 8 January 1997
Resolved
Provide corrected charts._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 8 January 1997
Resolved
Provide missing ring buoy lights._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 8 January 1997
Resolved
Provide servicing reports for fire extinguishers._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 8 January 1997
Resolved
Replace torn ring buoys._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 8 January 1997
Resolved
Repair holes to port side house, near WTD leading into engine room.
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 8 January 1997
Resolved
Tighten up hydrostatic releasing strap for life raft._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 8 January 1997
Resolved
Install the proper light bulbs for navigational lights._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 8 January 1997
Resolved
Provide missing EPIRB and provide registration paper._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 8 January 1997
Resolved
Clean out upper deck drains._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 8 January 1997
Resolved
Replace broken CO2 horn for extinguisher in forward hold._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 8 January 1997
Resolved
Provide evidence of drug testing program._x001C_
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 8 January 1997
Resolved
Vacuum out bilges and provide serving reports. COTP
Condition: Unknown
Due 7 February 1997
Resolved 13 January 1997
Fire Fighting
Issued 8 January 1997
Resolved
Provide service report for semi-portable fire extinguisher in engine room.
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 8 January 1997
Resolved
Provide evidence of hydro on outboard semi-portable CO2 bottle in engine room.
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 8 January 1997
Resolved
Correct excessive oil leak on starboard main engine aft corner.
Condition: Unknown
Due 7 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past