Records from 2005 to 2025. Most recent: inspection, 23 June 2025.
Documentation record
Registered dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)147.5 ft × 29.5 ft × 10.8 ft
ITC tonnagegross 341 / net 102
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 2005
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it102 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
341 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
23 June 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8165214
23 June 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8166418
28 August 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7991314
7 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7787595
25 May 2023
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7696609
7 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7553314
29 September 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7322854
29 June 2021
Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7239053
17 May 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7200261
8 June 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6970964
26 July 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6776634
25 June 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6724780
12 June 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6711003
5 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6533211
23 June 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6184602
20 June 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6181741
8 September 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5987462
24 October 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5008911
21 October 2014
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5010140
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200233
13 July 2009
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3533237
17 February 2009
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3419748
13 February 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3417472
13 February 2009
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3417642
15 May 2008
Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3207132
12 July 2007
Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2973909
3 October 2006
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2791784
17 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2571698
18 July 2005
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2430620
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 July 2025
Resolved
An interconnected detection and alarm system must be installed so that the actuation of the alarm in one area results in both audible and visual alarms in all areas required to be protected by the interconnected detection and alarm system. Audible and visual alarms were not present in the machinery space or the steering gear room.
46 CFR 181.450(a)(2)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 2 July 2025
Resolution: Vessel rep had two horn/strobe fire alarms installed in the machinery and rudder room.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 July 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Man overboard instructions are generic and do not match onboard procedures.
46 CFR 185.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2025
Resolved 9 July 2025
Resolution: Man overboard procedures updated to reflect actual method.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 28 August 2024
Resolved
A hatch exposed to the weather must be watertight. MI observed a leak on the port engine soft patch. Make hatch watertight to the satisfaction of USCG MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2024
Resolution: Vessel rep submitted photos of newly sealed hatch as well as attesting to satisfactory water test.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 August 2024
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. MI observed inadequate emergency lighting below deck. The installed emergency lighting was very dim and did not allow for safe passage to emergency escapes. Install adequate lighting from within all accessible passenger and crew accommodations to all emergency escapes.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 September 2024
Resolution: Vessel rep submitted photos of satisfactory emergency lighting.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 September 2021
Resolved
MULTIPLE CRACKS FOUND IN DECK AND HULL PLATING THAT AFFECT THE SEAWORTHINESS OF THE VSL.
- STBD SIDE RESCUE ZONE DOOR AT THE DECK LINE.
- STBD QUARTER UNDER FANTAIL OVERHANG.
- STBD MAIN DIESEL ENGINE EXHAUST OVERBOARD, TOP CORNERS.
- GALLEY STBD SIDE AFT ACCESS, 3 CRACKS IN OVERHEAD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2021
Resolution: All cracks welded, visually inspected and hose tested; all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 September 2021
Resolved
HATCHES EXPOSED TO WEATHER MUST BE WATERTIGHT. PORT SIDE ENGINE HATCH (SOFT PATCH) LEAKS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2021
Resolution: Sealant added to soft patch, tested, does not leak.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 September 2021
Resolved
EACH CLASS 1 DOOR MUST BE WATERTIGHT. FOUR DOORS BELOW DECK (GALLEY TO RUDDER ROOM) DO NOT SEAL.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2021
Resolution: All WTD adjusted to properly seal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2021
Resolved
ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED AND MAINTAINED TO AVOID CAUSING FIRE, FAILURE, OR PERSONNEL INJURY. THE FOLLOWING FLEXIBLE FUEL HOSES WERE FOUND NOT SERVICABLE:
- FUEL HOSES ON MAIN DIESEL ENGINE RACOR FILTERS (FOUR TOTAL)
- FUEL SUPPLY HOSES ON MAIN DIESEL ENGINES (FOUR TOTAL, ONE ON EACH ENGINE)
- FUEL HOSE ON BOW THRUSTER DIESEL ENGINE
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 30 September 2021
Resolution: All hoses replaced with proper fuel hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 September 2021
Resolved
ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED AND MAINTAINED TO AVOID CAUSING A FIRE, FAILURE, OR PERSONNEL INJURY. STBD INBOARD MAIN DIESEL ENGINE HAS A MISSING FUEL RAIL BRACKET AND MULTIPLE MISSING BRACKET GROMMETS. STBD INBOARD MAIN DIESEL ENGINE HAS MULTIPLE FUEL LEAKS AT THE INJECTOR CONNECTIONS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 5 October 2021
Resolution: Rcvd diesel engine tech report documenting corrections to main diesel engines, see documents for report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2021
Resolved
FLEXIBLE NONMETALLIC HOSE MUST MEET SAE J-1942 SPECS. STBD GENERATOR OIL GAGE SUPPLY LINE HAS INCORRECT HOSE (AIR BREAK LINE HOSE) INSTALLED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 30 September 2021
Resolution: Hose replaced with proper speced hose.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 29 September 2021
Resolved
EACH ENTRANCE TO A SPACE STORING CARBON DIOXIDE CYLINDERS AND PROTECTED BY CARBON DIOXIDE SYSTEMS MUST BE MARKED. ENGINE ROOM AND GENERATOR ROOM (PROTECTED SPACES), AND RUDDER ROOM (STORE SPACE) WERE NOT PROPERLY MARKED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 30 September 2021
Resolution: Signs properly posted on space entry doors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Each life jacket must be marked with Type I retro reflective material approved in 46 CFR 164.018. Four life jackets were found to be painted over the retro reflective material. The crew members removed the paint from the life jackets prior to the conclusion of the inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: The crew members removed the paint from the life jackets prior to the conclusion of the inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 25 June 2019
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas shall provide transfer procedures. The transfer procedures were not on the vessel and the transfer procedures were provided to the vessel prior to the conclusion of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: The transfer procedures were not on the vessel and the transfer procedures were provided to the vessel prior to the conclusion of the inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 25 June 2019
Resolved
All equipment, including switches, fuses, lampholders,
etc., must be suitable for the voltage and current
utilized. A power strip cord was discovered in a crew
cabin space. The power strip cord was removed from the
space prior to the completion of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Resolution: The power strip cord was removed from the
space prior to the completion of the inspection.
Construction/Loadline › Hull › Hull Plating
Issued 13 February 2009
Resolved
Perform temporary repairs to tear in way of bow nose, send pictures to USCG attending inspector and inspector will inspect temp repair and clear vessel for departure. and Continue voyage to Morgan City for permanent repair. Upon arriving to Morgan Cit call Cognizant USCG for inspection.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 February 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2007
Resolved
Remove dead-end wire behind access panel in crew accommodation space head.
Due 26 July 2007
Resolved 20 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 July 2007
Resolved
Properly secure wiring behind panels in port crew accommodation spaces.
Due 26 July 2007
Resolved 20 July 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 July 2007
Resolved
Provide updated current tables.
Due 26 July 2007
Resolved 20 July 2007