Records from 2005 to 2007. Most recent: inspection, 30 March 2007.
Inspection history · 12
30 March 2007
ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2898651
30 January 2006
PI Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2575932
27 January 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2575013
17 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2571698
21 October 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2532229
11 October 2005
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2523452
15 September 2005
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2493057
18 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2466691
3 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2466609
2 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2457950
1 August 2005
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2447417
25 July 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2439828
Construction/Loadline › Structures › Door
Issued 30 March 2007
No resolution recorded
WTD leading into steering gear room is missing 1dog. Satisfactory means shall be provided for closing openings for watertight integrity purposes.
Action required: 705 - Other - as specified
Lifesaving › Visual Distress Signals (General) › Condition
Issued 30 March 2007
No resolution recorded
Emergency light in aft engine room not mounted properly. Mount fixture per original arrangement.
Action required: 705 - Other - as specified
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 30 March 2007
No resolution recorded
low lube oil alarm on stbd inboard engine inop.
Action required: 705 - Other - as specified
Communications › Radio Communications › EPIRB
Issued 30 March 2007
No resolution recorded
Hydrostatic release on EPIRB expired. Alternate arrangements have been approved by RO until new hydro is acquired.
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 30 January 2006
Resolved
The vessel's Interim Safety Management Certificate issued by classification society expired on 08 January 2006. All other statutory Solas certificates issued by this classification society were provisional and dated with an erroneous expiration date of 30 February 2006.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 30 January 2006
Resolved
The vessel's minimum Safe Manning Certificate issued by Panama requires two (2) Watchstanding Deck Officers or (1) Dedicated Radio Officer with the appropriate GMDSS Radio Operator Certificate. Only one of the vessel's current Deck Officers had a valid GMDSS certificate. The other Deck Officer's certificate was expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 30 January 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Documentation › Certificates/Documents › IOPP Certificate
Issued 30 January 2006
Resolved
The vessel's IOPP Form (A) did not reflect the correct condition of the vessel, whereas, it did not identify the manufacturer of the oil content meter on the oily water separator, whether the vessel has a Shipboard Oil Pollution Emergency Plan or standard discharge connection. The form had essentially not been filled out correctly by the Classification Surveyor.
Action required: 705 - Other - as specified
Resolved 30 March 2007
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 1 August 2005
Resolved
Vessel is missing an approved ballast water managment plan. Needs to submit a plan prior to next U.S. port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 11 October 2005
Resolution: Vessel specific BWM plan accepted.