Inspection history · 39
27 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8377154
30 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8244427
15 July 2025
Deficiency Check · Internal Structural Exam · COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 8182414
4 March 2024
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7874113
8 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7846556
8 December 2022
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7606117
23 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7319235
28 June 2021
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7241847
3 September 2020
COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7049229
9 November 2017
DAPI Audit · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6304184
30 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6297498
9 December 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6055368
12 October 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 6021155
9 October 2015
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5739629
18 September 2015
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5722628
6 October 2014
Administrative Inspection · Annual Inspection · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5000023
5 October 2014
Examination of Repairs · MTSA Verification · Damage Survey · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4999829
5 October 2014
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 5001004
11 October 2013
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4735790
11 October 2013
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4759306
22 July 2013
Deficiency Check · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4662331
20 December 2012
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4507258
13 November 2012
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4480923
15 November 2011
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4189124
24 October 2011
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4174592
4 October 2011
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4161385
23 September 2011
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4152552
18 October 2010
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3875041
13 October 2010
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3869239
16 March 2010
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3702595
6 January 2010
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3659608
24 February 2009
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3423196
21 January 2009
Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3397724
15 September 2008
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3325665
10 September 2008
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3322734
21 February 2008
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3151012
30 January 2008
Type not recorded
No type recorded · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3151043
20 November 2006
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2829345
26 October 2005
Deadweight Survey · Initial Certification · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2523934
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel was observed to have improperly marked life jackets. 03 youth life jackets need to be replaced.
46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 March 2024
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel.(b)(1) Lloyd's Yachts and Small Craft, (2) ABS Steel Vessel Rules.
There are two sharp insets on the KINGS POINT FERRY II in the way of the linking mechanisms on the ITV EDEN. One of the insets has punctured the hull resulting in an approximately 3" by 1" hole. Develop a repair proposal and submit it to the attending marine inspector. Make repairs in accordance with the approved repair proposal.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 4 March 2024
Resolved 15 March 2024
Resolution: Witnessed satisfactory air test on two inserts.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2022
Resolved
The owner or managing operator... must conduct the following inspections and tests... portable extinguishers must be inspected and maintained IAW NFPA 10.
The portable extinguishers had not been serviced in the previous 12 months. Provide evidence of service or replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 20 December 2022
Resolution: Fire Extinguishers have been inspected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 December 2022
Resolved
ew installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel... must comply with this part.
All cable and wire must... be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage.
The new wire instillations on the hydraulic system and the generator do not meet the requirements of 183.340(b)(4). Bring the new wires/cables into compliance to the satisfaction of the OCMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2023
Resolved 14 February 2023
Resolution: Objective Evidence in the form of photographs were sent to the attending MI. The photos showed the wire's in question properly fastened to the overhead.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 October 2020
Resolved
Failure to have onboard up to date nav publications and tide tables, during the COI the company was not able to show any nav publications onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 8 October 2020
Resolution: Company showed all up to date nav pubs to inspector
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 October 2020
Resolved
The name of the vessel must be marked in clearly legible block capital letters with the vessel's name on each ring buoy, during the inspection, no ring buoys were marked with the vessel name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 9 October 2020
Resolution: Marked all ring buoys with proper vessel name
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 October 2020
Resolved
A vessel must carry either a first-aid kit approved under approved series 106.041 or a kit with equivalent contents and instructions, during the inspection inspector discoverd several items expired or missing from the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Company replaced the first aid kit with a complete and current first aid kit.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 November 2017
Resolved
show proof of drills being conducted. Vessel should log drills in record book or log book
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 6 October 2020
Resolution: Cleared during COI.
Personnel › Training › First Aid/CPR
Issued 9 November 2017
Resolved
CPR card expired , 25% of crew must be CPR certified.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 6 October 2020
Resolution: Cleared during COI
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 9 November 2017
Resolved
Nave rules not onboard, must have newest edition
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 6 October 2020
Resolution: cleared this during the COI.
Lifesaving › Lifebuoys › Serviceable
Issued 12 October 2016
Resolved
Lifebuoy was delaminating/deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2016
Resolved 9 December 2016
Resolution: Replace Life Ring
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 October 2016
Resolved
Lifebuoy light missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2016
Resolved 9 December 2016
Resolution: Replaced Float Light.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 12 October 2016
Resolved
1 portable fire extinguisher low charge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 November 2016
Resolved 9 December 2016
Resolution: Provided inspected fully charged extinguisher
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 October 2014
Resolved
Draft Marks needs to be in constracting color of the hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 28 October 2014
Resolution: Draft marks painted
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 October 2014
Resolved
Provide PFD's markings for Vsl Name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 6 October 2014
Resolution: Proper marking has been provided to PFD''''''''s
Fire Fighting › Fire Pumps › Location
Issued 6 October 2014
Resolved
Provide two operational fire pumps as required under COI conditions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2014
Resolved 6 October 2014
Resolution: Two operational fire pumps onboard the vessel after the replacement of a damaged pump during annual inspection.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 5 October 2014
Resolved
Water leak in Voids #5 & #1.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 October 2014
Resolved 28 October 2014
Resolution: Inspected repairs and conducted air test. Test Sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 October 2014
Resolved
Adult Lifejacket Missing
Condition: Placed in Improper Service
Due 5 October 2014
Resolved 5 October 2014
Resolution: Corrected on the spot.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 July 2013
Resolved
Crew training log non existent.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 August 2013
Resolved 24 August 2013
Resolution: Trianing log onboard.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 24 July 2013
Resolved
Vessel has no means to recover man overboard. Vessel required to place boat hook in service.
Action required: 705 - Other - as specified
Due 24 August 2013
Resolved 24 August 2013
Resolution: Vessels has boat hook onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 July 2013
Resolved
Medical kit very depleted and incomplete.
Condition: Improper/Lack of Maintenance
Due 31 July 2013
Resolved 6 August 2013
Resolution: First aid kit replaced with brand new kit.
Fire Fighting › Fire Pumps › Pressure
Issued 22 July 2013
Resolved
#2 Fire Pump inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 23 July 2013
Resolution: Pumped was operated satisfactorily.
Fire Fighting › Nozzles › Type
Issued 22 July 2013
Resolved
Fire fighting nozzle was designed with one spray patter (staight stream).
Condition: Improper Installation
Due 31 July 2013
Resolved 24 July 2013
Resolution: Proper fire fighting nozzle placed in service.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 July 2013
Resolved
Aft, outboard most watertight hatch has damaged gasket.
Due 22 August 2013
Resolved 6 August 2013
Resolution: Gasket replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 22 July 2013
Resolved
Vessels lifering fractured at seems.
Due 31 July 2013
Resolved 23 July 2013
Resolution: Replaced with new life ring.
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 22 July 2013
Resolved
PFD Stowage container was not locked but is capable of being locked.
Condition: Design Flaw
Due 31 July 2013
Resolved 24 July 2013
Resolution: Locks removed from life jacket stowage locker.
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 22 July 2013
Resolved
PFD Stowage locker not marked with amount of jackets inside.
Condition: Design Flaw
Due 31 July 2013
Resolved 31 July 2013
Resolution: PFD Locker Marked.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 July 2013
Resolved
Training/Drill Log non existent. Returning to vessel 24JUL2013 to conduct drills and inspect drill log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2013
Resolved 24 July 2013
Resolution: Man Overboard and Fire Drill conducted.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 July 2013
Resolved
Life jacket donning palcard missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2013
Resolved 12 August 2013
Resolution: Posted Lifejacket Donning Placards.
Fire Fighting › Fire Pumps › Pressure
Issued 13 November 2012
Resolved
Provide proper operation of fire pump and fixed bilge system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 December 2012
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 November 2012
Resolved
Provide two (2) additional adult life jackets to meet number on COI. Vessel is restricted to 20 total passengers until life jackets are supplied.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 December 2012
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 November 2012
Resolved
Fix rail course
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 December 2012
Engineering › Steering Gear System › Hydraulic Hose
Issued 13 November 2012
Resolved
Fix hydraulic leak port side forward in engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 December 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 November 2012
Resolved
Clean storage lockers were the PFD's are stored.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 December 2012
Fire Fighting › Fire Main › Condition
Issued 13 November 2012
Resolved
Paint valves on fire main system to reflect colors that reflect what is shown on instruction placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 December 2012
Construction/Loadline › Hull › Weld
Issued 13 November 2012
Resolved
Repair weld on port side connection point.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2012
Resolved 20 December 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 October 2011
Resolved
Secure floating waterlight IAW 180.70(d)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 November 2011
Resolved 15 November 2011
Resolution: Added 3'' piece of line with clip.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 24 October 2011
Resolved
Label vessel name on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2011
Resolved 15 November 2011
Resolution: Properly labeled lifejackets with name of vessel.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 October 2011
Resolved
Label lifejacket storage with proper label for adult/children and quantity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2011
Resolved 15 November 2011
Resolution: Labelled both adult and child storage area.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 October 2011
Resolved
Install placard with instructions on how to properly put on a lifejacket.
Condition: Improper/Lack of Maintenance
Due 24 November 2011
Resolved 15 November 2011
Engineering › Bilge Water Management System › Not Operational
Issued 18 October 2010
Resolved
Could not prove operation of bilge high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2010
Resolved 21 October 2010
Resolution: Proved proper operation of alarms.
Fire Fighting › Nozzles › Type
Issued 18 October 2010
Resolved
Did not have proper nozzle attached to the 1 1/2" hose. Replace straight stream nozzle with a nozzle that can change between straight stream and fog patterns.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2010
Resolved 21 October 2010
Resolution: Replaced nozzle with proper one.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 October 2010
Resolved
Replace 05 worn lifejackets with 05 new ones.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2010
Resolved 21 October 2010
Resolution: 05 new life jackets onboard.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 18 October 2010
Resolved
Must have 01 lights attached to lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2010
Resolved 21 October 2010
Resolution: Placed brand new light on life ring.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 January 2010
Resolved
Maximum passenger count reduced to 20 until owner/operator outfits vessel with full compliment approved life jackets in accordance with the COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2010
Resolved 16 March 2010
Resolution: Replaced with new ones.
Lifesaving › Lifebuoys › Serviceable
Issued 6 January 2010
Resolved
Outfit with ringbouy to include life line. Life line must be dark in color or must be certified resistant to UV lightiaw 46cfr180.70(c) and 40cfr180.70(d).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 February 2010
Resolved 16 March 2010
Resolution: Replaced with new ones.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 November 2006
Resolved
Make access to boat safer by installing handrails as needed. Another fix would be to install two gates, one at each end to allow access at boat handrail.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 21 February 2007
Resolution: Handrails installed.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 20 November 2006
Resolved
Make Anchor ready to drop by one deckhand located on barge.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 21 February 2007
Resolution: Anchor installed on outboard side of hand rail.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 November 2006
Resolved
Mark lifejacket box with number of jackets.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 21 February 2007
Resolution: Number painted on life jacket boxes.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 20 November 2006
Resolved
Make rescue baot able to be launched by one deckhand safely.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 21 February 2007
Resolution: Electric winch installed and drill conducted sat.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 20 November 2006
Resolved
Prove anchor is adequate for the vessel.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 21 February 2007
Resolution: Anchor is now safer to operate.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 October 2005
Resolved
Install lagging on both main engine and genset exhaust piping.
Action required: 705 - Other - as specified
Resolved 27 October 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 October 2005
Resolved
Provide letter form the [name withheld] Board of Supervisors attesting that it is the counties intention to operate/maintain the vessel as a CG certificated vessel and will comply with CG requirements applicable to the vessel type. Current Temporary certificate will be rescinded if this requirement is not satisfied.
Action required: 705 - Other - as specified
Resolved 27 October 2005