MAURY USCG vessel records
← All vessels

CHENA

Built
1959
Last inspected
23 September 2024
Controls
None recorded without a removal date
Also recorded as
CENTAUR (2011)

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 23 September 2024
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2004–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG8706
Flag
UNITED STATES
Tonnage
91 - Regulatory (Subpart C or D), Gross Ton 35 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-75282
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

SEA-LITE I Tank Barge · MISLE 55012 · 30 September 2016 · activity 6016118ZB-19 DELTA VIKING Freight Barge · MISLE 88625 · 13 August 2011 · activity 4127653

Inspection history · 18

23 September 2024 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8007950
10 June 2024 Deficiency Check · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7937401
30 October 2023 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7979906
3 October 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7796180
12 June 2023 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7724764
14 July 2022 Administrative Inspection · Initial Certification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7506139
14 October 2021 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7337218
3 August 2021 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7276297
30 September 2016 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6016118
29 August 2013 Industry Initiated Exam
Physical examination · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 4708196
8 May 2012 Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4780343
30 August 2011 Administration
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4131203
13 August 2011 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4127653
6 November 2006 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2815258
15 September 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2779015
26 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2573650
25 January 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2573117
15 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1985847

Deficiency record · 30

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 July 2024 Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. The following seaworthiness and fitness deficiencies were noted during a cursory out of the water exam required by COTP order #004-24: Epoxy repair to the hull plating below the waterline just forward of shaft alley, unauthorized inadequate clad weld repairs to hull plating just forward of engine room, hole below the waterline in severely wasted plate near the bow adjacent to centerline, new doubler plates near bow (center & port side), internal structural members throughout vessel are crushed,tripped,wasted & distorted, and some decks have completely wasted away and have been covered by plywood with diamond plating lying on top. The vessel's hull plating appeared visually thin and was randomly gauged with UT by the Port Engineer, the results were at best 40% wastage and in some locations the hull plating showed greater than 50% wastage. Overall the vessel is not fit for service. Make the remaining fuel tanks/voids available for inspection along with a certified gauging company to finish the assessment of the hull and structures. Upon completion provide a repair proposal to Sector Western Alaska & U.S. Arctic for approval. *Vessel is hereby detained until all required repairs have been completed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 24 July 2024
Resolved 24 September 2024
Resolution: Vsl COI revoked. Vsl laid-up no longer in service. Vsl must complete satisfactory COI, DDX, and ISE to return to service.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 10 June 2024 Resolved
No repairs affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel drydocked and conducted repairs with no notification to CG. Provide repair proposal for CG review and approval. Repairs are to be completed and approved by attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2024
Resolved 23 September 2024
Resolution: Vessel's COI was revoked, Vessel will have to undergo full COI inspection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2024 Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.A 40-B portable fire extinguisher must be located near the storage room or cabinet. Paint locker had no 40-B fire extinguisher located near it. Install a 40-B fire extinguisher near the paint locker.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2024
Resolved 10 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 June 2024 Resolved
The following systems must be equipped with gauges at the machinery location: Main engine lubricating oil pressure and main engine RPM; Main engine cooling water temperature; Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM; Auxiliary generator engine cooling water temperature. All four main engines have no RPM gauges. Generator has no RPM, oil pressure, and cooling water temperature gauges. Install all required gauges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 23 September 2024
Resolution: Vessel's COI was revoked, Vessel will have to undergo full COI inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 October 2023 Resolved
Vessel's LOMAVIK, CHENA and RIVERWAYS 14 were beset in ice while conducting cargo operations IVO of Nunapitchuk, AK in the Johnson River. Due to the potential for structural damage from the ice, vessels are required to conduct Internal Structural Exam prior to operating with Cargo. 46CFR31.10-21 46CFR137.325
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2024
Resolved 10 June 2024
Resolution: ISE completed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 October 2023 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Berthing space had no smoke detection installed. Install smoke detection in berthing spaces.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 3 October 2023
Resolved 3 October 2023
Resolution: Smoke detectors installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 3 October 2023 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Two of the four shaft seals are actively leaking. Repair or replace shaft seals.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Tightened shaft seals.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 October 2023 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. No ventilation cutoff installed.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 13 June 2024
Resolution: Ventilation cutoffs configured and installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 October 2023 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure all bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive oil and water found in bilges. Remove oil and water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Oil and water was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2023 Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. No designate storage room or cabinet for paints, coatings, and oil found in machinery space and under deck. Designate and area or install cabinet to store these products.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Items are now stored in paint locker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 October 2023 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Exhaust piping had lagging laying on pipes but where not secured. Install secure lagging onto all exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Lagging in place and secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical outlets in machinery space are missing their covers and visible oil and soot buildup can be seen internally. Repair or replace outlets with installed covers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Replaced outlets and covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 October 2023 Resolved
Verification of compliance with the machinery and electrical design standards in this subpart is obtained by following the provisions in §§ 144.135 through 144.145 of this subchapter. An additional generator, which supplies power to the main switch board, was discovered to have been permanently installed on the aft deck since the vessel received it’s COI. There was no verification of installation or approved plans for the new installation by an approved individual or entity. Provide plans and get approval from a registered professional engineer, authorized classification society or Coast Guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Generator was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 October 2023 Resolved
The second source of supply required by § 143.555(a)(3) must automatically start to help restore or maintain power to propulsion, steering, and related controls when the main power source fails. There is no automatic start for second generator. Install automatic start.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Secound generator was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2023 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Bilge system had no check valves and float switches in machinery space were well above bilge and located on deck plating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Vessel uses portable bilge pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2023 Resolved
Piping for flammable or combustible liquid, seawater cooling, or firefighting systems must be fitted with isolation valves that are clearly marked by labeling or color coding that enables the crew to identify its function. Labels or color coding not present or unidentifiable. Bilge system and manifold not labeled or color coded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Its colored coded but they use a portable pump now.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 October 2023 Resolved
Each towing vessel must be capable of preventing all oil spills from reaching the water during transfers by pre-closing the scuppers/freeing ports. Scupper plug was not present at the fuel fill fixed containment. Replace or procure scupper plug and have readily available.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Scupper plug in place.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 3 October 2023 Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion-resistant flame screen. Vents from two or more fuel tanks may combine in a system that discharges on a weather deck. No 30 by 30 mesh flame screen installed on vent. Install flame screen.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Mesh installed.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 October 2023 Resolved
Each liferaft or group of liferafts must be arranged for float-free launching. The arrangement must ensure that the liferaft or liferafts, when released and inflated, are not dragged under by the sinking vessel. Life raft cradle is not secured to the vessel. Remove or replace life raft cradle.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Route changed to Rivers. No raft required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2023 Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions. Semi portable fire extinguisher was not attached to prevent rolling. Install support to prevent rolling.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Extinguisher is now bolted to deck.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 3 October 2023 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Setting of PRV not designated or legible. Replace PRV.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: PRV on order. Receipt was shown.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2023 Resolved
Electrical cables must be suitably protected from wet and corrosive environments. Cable penetrations to the exterior of the house were not suitable protected from environmental conditions and exposed wood structure to water damage and rot.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Plugs and caulk installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 October 2023 Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedure. At the time of inspection, no health and safety manual was onboard vessel. Once manual arrived on vessel there was no evidence of a lock out tag out procedure. Ensure vessel has permanent copy on board vessel and a lock out procedure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Viewed company lock out tag out procedures.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 3 October 2023 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The compass or swing-meter must be readable from each operating station. Magnetic compass is not illuminated. Replace with illuminated magnetic compass.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Compass illuminated.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 October 2023 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. No day shapes were present on vessel. Install required day shapes on vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Day shapes on board.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 October 2023 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: Search light, controllable from the vessel's operating station and capable of illuminating objects at a distance of at least two times the length of the tow. Search light control was inoperable. Repair or replace search light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Search light is now operable.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 October 2023 Resolved
At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. Both lifebouys have life line attached to body. Remove one life line from lifebuoy body.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Life line removed.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 October 2023 Resolved
Each lifejacket must be marked In block capital letters with the name of the vessel. Life jackets were not marked, mark life jackets with vessels name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Life Jackets are marked.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 3 October 2023 Resolved
Portable watertight containers for pyrotechnic distress signals must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2023
Resolved 10 June 2024
Resolution: Container labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 August 2021 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 November 2021
Resolved 3 November 2021
Resolution: Co at 75%.

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.