MAURY USCG vessel records
← All vessels

MICHELLE M

Built
1959
Last inspected
24 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 24 March 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 15 calendar years (1997–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM9274
Flag
UNITED STATES
Maury page id
psix-75697

Documentation record

Registered dimensions (L × B × D)45.9 ft × 19.0 ft × 5.0 ft
Registered tonnagegross 42 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMISSOURI DRY DOCK & REPAIR CO · CAPE GIRARDEAU, MO, UNITED STATES · built 1959
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMILWAUKEE, WI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LINWOOD ENDEAVOR Towing Vessel · MISLE 10885 · 22 November 2012 · activity 4489202

Inspection history · 19

24 March 2026 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8331410
23 June 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8161431
14 May 2025 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8136420
30 July 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7950084
20 July 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7748193
26 January 2023 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7627376
5 May 2022 COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7444547
10 February 2021 Administrative Inspection · Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7138565
13 November 2020 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7094696
22 September 2019 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6818737
22 September 2019 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6825310
7 November 2017 Administration
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6302239
7 June 2017 DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6189474
3 June 2015 Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5143403
22 November 2012 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4489202
5 January 2010 MTSA Verification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3660236
4 September 2009 Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3589846
9 March 2006 Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2602141
21 February 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 401445

Deficiency record · 9

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 July 2024 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Stern white navigation light was in operable. Replace prior to operating at night or reduced visibility.
Action required: 705 - Other - as specified
Resolved 1 August 2024
Resolution: New stern light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2024 Resolved
The following systems must be equipped with gauges at the machinery location: (3) Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. Generator was not equipped with RPM gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 9 August 2024
Resolution: New RPM gauge installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2024 Resolved
If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either:(1) A flammable liquid storage cabinet that satisfies UL 1275; or(2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050. Flammable storage cabinet had 4 holes drilled into the backside, and need to be sealed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 9 August 2024
Resolution: Repairs made to flammable storage cabinet.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 July 2024 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. The following items were noted: a. E/R vent louvers broken/damaged. b. Port and Starboard exhaust stack vent closures had significant gaps between closure device and opening. c. Port exhaust stack had a hole in the side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2024
Resolved 9 August 2024
Resolution: New louvers installed, exhaust stack closure devices repositioned, and hole in port exhaust stack mechanically secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 July 2023 Resolved
The following systems must be equipped with gauges at the machinery location: main engine RPM and auxiliary generator engine RPM. Provide gauges in the machinery location within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 14 August 2023
Resolution: Recieved photo evidence of proper installation of gauges
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 March 2021 Resolved
Provide on board distress signals required in 46 CFR 141.375 and label stowage container "DISTRESS SIGNALS" in 0.5 inch letters prior to the next annual inspection.
Action required: 705 - Other - as specified
Resolved 21 September 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 February 2021 Resolved
Prove 120 minute operation of emergency lighting/ batteries prior to recertification/ inspection year 2025.
Action required: 705 - Other - as specified
Resolved 30 July 2024
Resolution: Retroreflective tape installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 November 2020 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 50% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 March 2021
Resolution: Vessel completed satisfactory COI inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2019 Resolved
Make permanent repairs to both main engines, due to engine failures
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2019
Resolution: Verified new steel braided lines installed at adequate length and ran outside of the turbo lagging. Witness test of low lube oil alarm, audio and visual and witnessed operation of both MDEs.

Recorded names · 1

DONN L WILLIAMS (2012–2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record