Records from 2005 to 2026. Most recent: inspection, 12 March 2026.
Inspection history · 83
12 March 2026
MSP Select Annual Oversight · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8325101
18 December 2025
Administrative Inspection
Administrative · Activities Europe · Activity 8285509
27 June 2025
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8170041
20 December 2024
MSP COI Oversight · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8047168
10 March 2024
Annual Inspection · MSP Periodic Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7877310
29 September 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7800571
13 March 2023
MSP Periodic Oversight · MTSA/ISPS Verification · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7646243
23 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626465
14 March 2022
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7411204
9 August 2021
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7596273
29 June 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7239639
22 March 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7160660
8 February 2021
MSP Annual Oversight · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7134447
7 November 2020
Type not recorded
No type recorded · Activities Europe · Activity 7107340
15 October 2020
Examination of Repairs · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7077642
14 October 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7077459
14 October 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7077858
30 September 2020
Type not recorded
No type recorded · Activities Europe · Activity 7069205
2 January 2020
COI Inspection · MSP COI Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6869738
14 June 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6714041
21 May 2019
Type not recorded
No type recorded · Activities Europe · Activity 6698887
4 April 2019
Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6656005
23 February 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6634073
8 January 2018
MTSA/ISPS Verification · Periodic Inspection · MSP Periodic Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6333360
30 December 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6443010
30 May 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6163982
17 March 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6107945
14 March 2017
Type not recorded
No type recorded · Activities Europe · Activity 6110753
16 January 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6073753
13 January 2017
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6069268
22 September 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6007228
1 August 2016
Type not recorded
No type recorded · Activities Europe · Activity 5959142
26 July 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5953178
11 March 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5831545
11 March 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5831560
27 November 2015
DAPI Audit · Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5770954
27 August 2015
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5228193
31 July 2015
Type not recorded
No type recorded · Activities Europe · Activity 5201651
26 October 2014
Type not recorded
No type recorded · Activities Europe · Activity 5018168
22 October 2014
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Activities Europe · Activity 5009788
2 October 2014
Drydock Extension
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5000234
3 February 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4238077
3 February 2012
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4238079
27 January 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4233173
24 January 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4231557
12 January 2012
Administrative Inspection
Administrative · Activities Europe · Activity 4223534
1 September 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4132878
31 August 2011
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4131766
10 July 2011
Type not recorded
No type recorded · Activities Europe · Activity 4077479
26 November 2010
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3898914
18 November 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3893943
11 November 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3889525
9 November 2010
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3888221
15 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3850660
13 September 2010
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3847125
13 September 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3850717
8 September 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3844976
19 February 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3682390
17 February 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3681877
8 February 2010
COI Inspection · Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex IV Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3676868
19 December 2009
Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 3658061
17 April 2009
Ballast Water Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3454390
6 April 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3447425
6 November 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3358515
25 October 2008
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3354539
12 August 2008
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3296221
2 August 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3287020
1 August 2008
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3286210
31 July 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3285583
31 July 2008
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3286089
31 July 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3286164
26 July 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3282358
10 May 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3203517
25 April 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3196521
27 March 2008
Deficiency Check · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3172589
26 February 2008
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3154090
23 January 2008
Ballast Water Examination · Reflagging & Initial Certification · MARPOL Annex I Examination · Administrative Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3134995
5 November 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3093066
5 November 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3093299
5 November 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3093895
19 July 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2718518
21 June 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2398116
20 June 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2396386
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 March 2023
Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship. Both port side liferafts' painters did not secure the liferafts to the ship.
74SOLAS(14)
Ch. III/13.3
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2023
Resolved 13 March 2023
Resolution: 10c - corrected prior to completion of inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 March 2023
Resolved
A power driven vessel underway shall exhibit a masthead light forward. Vessel's forward masthead light is burnt out.
33 CFR 83.23(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 March 2023
Resolved 13 March 2023
Resolution: Corrected prior to completion of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2023
Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. Eight electrical boxes in the engine room had the cable penetration material falling out of the cable penetration.
74SOLAS(04)
Ch. II-1/45.5.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 20 March 2023
Resolution: LR Report
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2023
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Vessel has four exposed wires in the gyro room.
74SOLAS (14)
Ch. II-1/45.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 20 March 2023
Resolution: LR Report
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 13 March 2023
Resolved
Vessel is required to have a voyage data recorder (VDR) that conforms to resolution A.861(20). Vessel's bridge port side VDR microphone is inoperable.
74SOLAS(14)
Ch. V/20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2023
Resolved 20 March 2023
Resolution: LR Report
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 March 2022
Resolved
In general, compliance with the standards established by the American Bureau of Shipping will be considered as satisfactory evidence of the structural efficiency of the vessel. Marine Inspector observed damage to the starboard side transom. Coast Guard Marine Inspectors must review and accept a Class Society report that evaluates the damage and makes recommendations for repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2022
Resolved 15 March 2022
Resolution: Lloyds surveyor wrote a condition of class (A1-C-015).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 January 2020
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. Means shall be provided to control leaks of flammable liquids. NO.1 Fuel Oil Purifier was leaking fuel oil into the containment. Clean pooled fuel oil containment and provide proof of proper repair. 74SOLAS(02) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 10 March 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 January 2020
Resolved
Daily service tanks having a capacity of 500L and above shall be situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside of the space concerned in the event of a fire. Quick Closing Valve (QCV) for fuel oil supply tank for Main Diesel Generators was found blocked in the open position, rendering it incapable of remote closure. 74 SOLAS (02) II-2/4.2.2.3.4
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 2 January 2020
Resolved 2 January 2020
Resolution: Block was removed and QCV tested in the presence of the MI.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 January 2020
Resolved
Each vessel must have a current magnetic compass deviation table or graph or compass comparison for the steering compass in the wheelhouse. Vessel did not have a current deviation table after departing drydock in December 2019. Provide updated compass deviation card prior to next US port.
33 CFR 164.35(c)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 January 2020
Resolved 10 March 2020
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 2 January 2020
Resolved
Simple operating instructions with a block diagram showing the change-over procedures for remote steering gear control systems and steering gear power units shall be permanently displayed on the navigation bridge and in the steering compartment. Vessel had operating instructions posted that were severely worn and unreadable. Provide new change-over operating instructions on bridge. 74 SOLAS(02) V/26.3.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2020
Resolved 12 January 2020
Resolution: new placard provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 January 2020
Resolved
Two-way portable radiotelephone apparatus shall be of an explosion proof type or intrinsically safe. Ships constructed before 1 July 2014 shall comply with the requirement of this paragraph not later than the first survey after 1 July 2018. Vessel did not have on board. Provide explosion proof or intrinsically safe portable hand held radios for firefighter communications. 74 SOLAS(14) II-2/10.10.4
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2020
Resolved 10 March 2020
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 2 January 2020
Resolved
Means shall be provided on the navigation bridge to indicate any loss of the required ventilating capacity. Upon testing of cargo ventilation shutdown, no audible alarm was heard on the bridge to notify crew of loss of ventilation.
74 SOLAS(02) II-2/20.3.1.3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2020
Resolved 10 March 2020
Lifesaving › Inflatable Liferafts › Not on Board
Issued 17 March 2017
Resolved
Vessel lost 20 man life raft on the port side while enroute from Alexandria Egypt to Aquaba, Jordan due to a failed life raft strap.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 10 April 2017
Resolution: Vessel provided proof to CG for new raft installment.
Lifesaving › Lifeboat › Exhaust Pipe
Issued 13 January 2017
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Lifeboat exhaust disassembled due to faulty part, rendering the lifeboat inoperable. Rectify prior to departure to satisfaction of attending Class Surveyor or USCG Marine Inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2017
Resolution: Resolved by attending Class Surveyor.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 27 November 2015
Resolved
The Dead timer personal alarm sound via the Vital System Automation was adjusted internally (by GSMS) within the company to reflect a new interval of 12 minutes vice previously approved interval of 30 minutes. Submit PSTP revision to reflect change.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 January 2016
Resolved 8 January 2016
Resolution: Received revision with revision page for change to PSTPs and endorsed it.
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2012
Resolved
Vessel to complete underwater hull survey following grounding. Dive report shall be forwarded to COTP Baltimore prior to the vessels departure from Baltimore.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2012
Resolution: Recieved dive report and Class report.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 February 2010
Resolved
Prove proper operation of 2cm radar to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 17 February 2010
Resolution: Received Tech. Report attesting proper operation of 2cm radar
Engineering › Steering Gear System › Pump
Issued 2 August 2008
Resolved
The number 1 steering Pump is still having problem communicating with the steering system. However, #2 system is fully operational. # 1 system can be used in emergency via emergency steering system. Class attended vessel and Class has given the vessel 30 days to repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 August 2008
Resolution: Witnessed satisfactory test, all sat.
Construction/Loadline › Structures › Door
Issued 1 August 2008
Resolved
Repair fractured weld on elevator door coming in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2008
Resolved 6 November 2008
Resolution: Repairs made.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 31 July 2008
Resolved
Post additional steering gear instructions on bridge and in steering gear identifying the control indicator for emergency steering and conduct training in regards to the procedures.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2008
Resolved 6 November 2008
Resolution: Procedures installed.
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 26 July 2008
Resolved
#1 Generator circuit breaker not allowing the #2 generator to stay online. Vsl has 3 generators. The 3rd generator is placed online to run the bow thruster. Therefore, vsl is unable to use bow thruster until this is fixed.
Action required: 705 - Other - as specified
Resolved 27 July 2008
Resolution: Repaired. Service engineer from generator manufacturer overhauled breaker and coil. Generator was then tested w/ no discrepencies.
Engineering › Steering Gear System › Pump
Issued 26 July 2008
Resolved
Vsl's #1 steering gear controller is not transmitting proper signal from #1 steering pump to the steering system. #2 system is unaffected.
Action required: 705 - Other - as specified
Due 31 August 2008
Resolved 5 August 2008
Resolution: Witnessed satisfactory test, all sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 23 January 2008
Resolved
Required MSD approval placard is not posted on the MSD
Due 5 June 2008
Resolved 6 May 2008
Resolution: verified placard was posted as required.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 23 January 2008
Resolved
Chief engineer and other engineer officer have errors on STCW endorsements referencing Z-card or licence. Crew members must recieve reissued STCW endorsements prior to sailing internationally.
Action required: 15 - Rectify deficiencies by next port
Due 11 February 2008
Resolved 8 February 2008
Resolution: Corrected mariner documnentation was provided.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 23 January 2008
Resolved
Found without vessel specific Ballast Water management plan, garbage management plan and Oil Transfer Procedures. Provide proof of vessel specific plans prior to departure from next US port.
Action required: 15 - Rectify deficiencies by next port
Due 11 February 2008
Resolved 8 February 2008
Resolution: Recieved report from the master that ship specific manuals had been generated based on the vessel''s ISM system draft manuals as required.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 January 2008
Resolved
Fixed extinguishing system for Galley deep fat fryer Ansul system is not indicated on the Fire Control Plan. Add to plan.
Due 5 March 2008
Resolved 8 February 2008
Resolution: Recieved report from vessel master that system had been indicated on the fire control plan and properly marked.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 November 2007
Resolved
Radar is not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2007
Resolution: Received tech report attesting to the proper operation of the radar.