Records from 2008 to 2024. Most recent: inspection, 8 February 2024.
Documentation record
Registered dimensions (L × B × D)144.0 ft × 50.0 ft × 8.0 ft
Registered tonnagegross 440 / net 132
ITC dimensions (L × B × D)144.0 ft × 50.0 ft × 8.0 ft
ITC tonnagegross 440 / net 132
BuilderMOBRO MARINE INC · GREEN COVE SPRINGS, FL, UNITED STATES · built 2005
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT CANAVERAL, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 August 2025 · expires 30 September 2026
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it440 - Convention (Subpart B), Gross Ton
132 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
8 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7862852
30 October 2023
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7818057
1 November 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7596341
23 August 2022
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7547229
4 February 2022
In-Service Inspection · Underwater Inspection in lieu of Drydock · Administrative Inspection · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7391036
4 February 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7404366
13 July 2021
Administrative Inspection · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7254590
8 March 2021
Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7152285
5 January 2021
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7161267
13 October 2020
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7078612
28 September 2020
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7066939
26 December 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6878959
2 December 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6865620
11 October 2019
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6835862
19 July 2019
Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6765978
23 October 2018
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6568082
17 July 2017
Administrative Inspection · COI Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6160471
11 July 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5937028
19 January 2016
MTSA Verification · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5800447
14 January 2016
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5797653
2 March 2015
Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5079372
17 September 2014
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4985662
11 August 2014
Annual Inspection · MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4951597
29 July 2013
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4669209
15 October 2012
Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4464711
14 October 2012
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4464729
24 September 2012
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4449230
20 April 2012
MARPOL Annex I Examination · Hull Examination · COI Inspection · Administrative Inspection · MARPOL Annex VI Survey · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4326723
12 September 2011
MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4142784
9 October 2008
MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3356388
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2023
No resolution recorded
Your vessel must undergo annual inspection within 3 months before or after the anniversary date. Annual inspection was due NLT 31 Aug 2023 and was not completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 31 October 2023
No resolution recorded
In general, compliance with standards established by ABS are considered satisfactory evidence of the structural efficiency of the vessel. Numerous holes and fractures are in the main deck which allow water to enter the voids below.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2023 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 31 October 2023
No resolution recorded
The assignmnet of load lines is conditioned upon the structural efficency and satisfactory stability of the vessel. The Load Line Certificate was not endorsed as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2024 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 February 2022
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter.
After towing vessel suffered a marine casualty, Barge 1912 was pushed onto the beach and grounded. After underwater survey vessel was issued a 15 days temporary Load Line Certificate to allow it complete its voyage. After Voyage is complete Owner is responsible for contacting ABS and Coast Guard to schedule an internal structural examination to ensure the safety and condition of the Barge before continue operations. Barge shall be made available for above inspection after arrival to Cape Canaveral Florida.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 February 2022
Resolved 30 August 2022
Resolution: Conducted UWILD on pier with ABS. Barge clear to depart with a short term
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 March 2021
Resolved
If during an internal structural exam (ISE), deterioration to the hull plating or structural members is discovered, the Officer in Charge of Marine Inspection, may require the vessel to be dry-docked or otherwise taken out of service to further assess the extent of the damage and affect permanent repairs. Extensive wastage in bottom longitudinal and transverse framing, hole in the headlog and temporary repairs, including a cement patch in #3 port bottom plating, were observed.
Credit will not be given for ISE until further assessment and subsequent repairs are completed. Barge is not permitted to carry cargo until ISE is completed.
Action required: 705 - Other - as specified
Due 5 April 2021
Resolved 20 May 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 September 2020
Resolved
Prove tow bridle is suitable for service or renew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 October 2020
Resolved 13 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2020
Resolved
Properly secure electrical conduit around periphery of barge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 October 2020
Resolved 13 October 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2019
Resolved
Properly install "keys" in ramp pulleys and renew cotter pins as needed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 December 2019
Resolved 26 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2019
Resolved
Renew fuel lines for generator and properly secure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2019
Resolved 2 December 2019
Operations/Management › Vessel Activity › Other
Issued 19 January 2016
Resolved
Barge Owner / Operator failed to make barge avaialble for inspection as required by Regulation. This deficiency was entered because enforcement referrral requires a deficiency for reference.
Condition: Improper/Lack of Maintenance
Due 19 January 2016
Resolved 19 January 2016
Construction/Loadline › Hull › Double Hull
Issued 11 August 2014
Resolved
Remove all water from the center stern void and make available for closer inspection.
Action required: 705 - Other - as specified
Due 11 August 2014
Resolved 11 August 2014
Resolution: Water was pumped out and tank observed for several hours with no further water.
Electrical › Electric Generation Source (service) › Generator
Issued 24 September 2012
Resolved
Provide plans to the MSC for approval of the generators, wiring, and associated fuel systems.
Action required: 705 - Other - as specified
Due 1 July 2015
Resolved 17 September 2014
Resolution: The generators on deck are portable and considered cargo.
Stability › Incline Test › General
Issued 24 September 2012
Resolved
The deadweight survey completed on 20 July 2005 does not account for the aft stern ramp. Paragraph 6 of the stability letter states alterations to the established parameters can invalidate the letter. Provide data to ABS regarding how the barge is currently outfitted for their review and comment regarding the stern ramp and any possible effects it has on the stability letter.
Action required: 705 - Other - as specified
Due 1 March 2013
Resolved 1 February 2013