Records from 2005 to 2023. Most recent: inspection, 1 November 2023.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 42
1 November 2023
ACP Additional Oversight – Risk Assessment · Re-Inspection · Administrative Inspection · ACP Periodic Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7891624
13 September 2023
Deficiency Check · ACP Handover Survey · MTSA/ISPS Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7789905
24 February 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7401147
25 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7385274
20 January 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7382891
16 November 2021
COI Inspection · MSP COI Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 7359195
5 November 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7349592
6 October 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7327649
7 September 2021
Administrative Inspection · MTSA/ISPS Verification · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7311006
26 August 2021
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7297406
14 January 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7135596
14 September 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7058038
6 April 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6935914
29 January 2020
DAPI Audit · MSP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6903186
15 November 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6856348
4 October 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6827983
22 August 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6791250
8 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6679938
2 May 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6675359
21 March 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6646617
1 February 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6618507
10 January 2019
Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6608480
24 September 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6547283
17 September 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6542316
7 September 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6535153
4 September 2018
Type not recorded
No type recorded · Activities Europe · Activity 6533571
4 September 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6536148
10 August 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6507280
9 June 2018
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6443917
10 May 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6410910
2 May 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6404001
5 April 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6385808
7 November 2017
Annual Inspection · MTSA/ISPS Verification · Administrative Inspection · MSP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6302875
29 March 2017
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6113902
6 March 2017
Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 6099902
24 February 2017
Type not recorded
No type recorded · Activities Europe · Activity 6094488
8 December 2016
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6054669
30 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6049914
1 October 2016
Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 6013688
15 September 2016
DAPI Audit · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5994201
3 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5896252
26 January 2016
Type not recorded
No type recorded · Activities Europe · Activity 5803441
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2024
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Citing overdue findings and condition of class reports from the vessel and the RO, there is objective evidence that the vessel is not in compliance with all statutory certificates. The owner/operator shall rectify outstanding items affecting the certificates to the Coast Guard, through the RO, to regain compliance with the vessel's current certificate of inspection.
74 SOLAS (2004 Cons.) I/11(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2024
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
In accordance with guidance from NCIV 2-95(CH-3), the company is responsible for rectifying RO findings and deficiencies identified by the Coast Guard within the time frame specified on the RO's report and/or CG-835.
The vessel has multiple outstanding conditions originating from the ACP Handover Survey CG-835, dated 09SEP2023, that do not meet class rules and affect the vessel's statutory certificates along with multiple outstanding finds from the vessel's annual class survey.
The owner/operator shall rectify outstanding items and/or request extensions or equivalencies, as applicable, to the Coast Guard through the RO.
74 SOLAS (2004 Cons.) I/11(a)
NVIC 2-95(CH-3)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 September 2023
Resolved
The following fire protection systems shall be kept in
good order so as to ensure their required performance
if a fire occurs: structural fire protection, including
fire-resisting divisions, and protection of openings.
The E/R supply fan #4 vent ducting is wasted and holed
in the steering gear space, adjacent to A0 boundary.
74 SOLAS (20)
II-2/14.2.1.1.1 Action Code: ac, Action: downgraded from 60
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 31 October 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2023
Resolved
Fire-fighting systems and appliances shall be kept in
good working order and readily available for immediate
use. Low pressure CO2 system is only able to be deployed
via emergency manual means due to in-operational
electronic Program Logic Circuit(PLC)card.
74 SOLAS (20)
II-2/14.2.1.2 Action Code: AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 31 October 2023
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2023
Resolved
Testing shall be carried out based on the guidelines
developed by the Organization and in a manner having due
regard to ensuring the reliability of fire-fighting
systems. Pre-discharge and discharge time delays were
not tested during the last function test of the low
pressure CO2 system.
74 SOLAS (20)
II-2/14.2.2.1 Action Code: AC
* Test to be performed in the presence of CG Marine
Inspector and ABS surveyor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 31 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The #1 & #2 main engine air
receivers’ relief valves would not seat after hand
lifting.
74 SOLAS(20) I/11(a) Action Code ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 September 2023
Resolved
Cargo vessels as defined by Title 46 CFR, must maintain
portable and semi portable fire extinguishers in
accordance with 46 CFR 95.50-10, per ACP U.S. Single
Supplement 2021. Portable extinguisher bracket E15 is
missing its extinguisher.
ACP Single U.S.
Supplement 3.1.2.10 Action Code ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 19 September 2023
Resolved
The following fire protection systems shall be kept in
good order so as to ensure their required performance if
a fire occurs: fire alarm systems. The CO2 powered air
horn is broken off for the e/r CO2 flooding alarm on the
starboard side forward mid level.
74 SOLAS (20)II-2/14.2.1.1 Action Code: ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 September 2023
Resolved
The main inlets and outlets of all ventilation systems
shall be capable of being closed from outside the spaces
being ventilated. The means of closing shall be easily
accessible as well as prominently and permanently marked
and shall indicate whether the shut-off is open or
closed. The ventilation closure for the paint locker did
not have indication of whether it was open or closed.
74 SOLAS (04) II-2/5.2.1.1 Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 September 2023
Resolved
Posters or signs shall be provided in the vicinity of
the survival craft and shall be easily seen under
emergency lighting conditions. Port side liferaft
launching were posted in vicinty of by general lighting
not on emergency lighting circuit.
74 SOLAS (20)III/9.2.2 Action Code ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 September 2023
Resolved
The main inlets and outlets of all ventilation systems
shall be capable of being closed from outside the spaces
being ventilated. The #6 ventilation closure, located
port side forward, would not properly latch when closed.
74 SOLAS (04)II-2/5.2.1.1 Action Code ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 September 2023
Resolved
All lifesaving appliances shall be in working order and
ready for immediate use. Both bridge wing lifebuoys
lights brackets are of a type not designed for quick
release operation. The falling ring will not pull the
light from the bracket when released.
74 SOLAS (20) III/20.2 Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 September 2023
Resolved
A training manual complying with the requirements of
paragraph 3 shall be provided … the following shall be
explained in detail: .1 donning of lifejackets and
and immersion suits. Onboard instructions for donning of
lifejackets and immersion suits are inaccurate to
reflect current styles carried onboard.
74 SOLAS (20) III/35 Action Code ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 19 September 2023
Resolved
All lifesaving appliances shall be in working order and
ready for immediate use.
The following lifeboat inventory items are not ready for
immediate use: the required rustproof drinking vessel
and waterproof container (containing the spare bulb and
batteries required for the flashlight) are fractured.
74 SOLAS (20) III/20.2 Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 19 September 2023
Resolved
Cargo ship survival craft embarkation arrangements shall
be so designed that the lifeboat can be boarded and
launched directly from the stored position. Ship has a
fabricated folding platform,on deck below lifeboat
storage, that extends about 3 feet beyond the hull for
embarking in the lifeboat. The crew was calling this the
embarkation area. This practice presents a safety hazard
for boarding the lifeboat because the lifeboat would
strike the platform/hull freely swinging in rough
weather and hang away from the platform/hull during
listing condition.
74 SOLAS (97)III/28.1 Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2023
Resolved
All electrical apparatus shall be so constructed and so
installed as not to cause injury when handled or touched
in the normal manner. The electrical cast iron wok
installed in galley has loose electrical cable and is
nonfunctional.
74 SOLAS (04) II-1/45.1.3 Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 September 2023
Resolved
All electrical apparatus shall be so constructed and so
installed as not to cause injury when handled or touched
in the normal manner. The electric oven, in galley, has
swinging door that will not latch closed and
nonfunctional griddle plates.
74 SOLAS (04) II-1/45.1.3 Action Code ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. Hydraulic leak is present at deck 5
port mooring station.
74 SOLAS (20) I-11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain safe to proceed to sea without danger to the ship
or persons onboard.Several emergency lights located on
the mess deck failed to illuminate on emergency power.
74 SOLAS (20) I-11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. Pneumatic line used for natural
ventilation hatch operation is disconnected, aft port side uppermost cargo deck.
74 SOLAS (20) I-11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The oil-fired boiler (OFB)
automation monitoring and alarm system in the ECR is not
operating as designed. The engine room is required to be
manned with 1 licensed engineer, and 1 oiler while the
OFB is in operation. Hourly rounds and logging of
operational parameters are required to be made when the
OFB is in operation.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The wire bracket for the #2
steering motor power cable has cracked welds.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The #1 steering systems #1 cylinder
gauge tubing is leaking hydraulic oil in the vicinity of
the valve packing.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The aft door entering the steering
gear space is improperly marked showing the space is
protected by CO2 although the space doesn’t have
installed fire protection.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The overhead drain line in the
steering gear space in way of aft exit is wasted and pin
holed.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. Both steering gear sight glass
hydraulic oil sump level indicators are leaking.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The cooling water pipe starboard
side aft above the h/o tank for the aft mooring winches
and ramp is wasted and pin holed.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The bracket for the #5 pump
hydraulic oil supply hose is cracked.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 31 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. Three nonmetallic flex hoses for
the hydraulic oil tank supplying the aft mooring winches
and ramp are chaffed and damaged.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The #3 hydraulic oil pump motor
wires for aft mooring winches and ramp are being held in
place with electrical tape.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The #4 hydraulic oil pump motor
wires for aft mooring winches and ramp are loose.
74 SOLAS(20) I/11(a) Action Code ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The overhead hatch in front of the
#1 steering pump is showing signs of leaking.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. Found 2 soft patches on the piping
supplying the MDE clean drain tank under the propulsion
shaft.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The vent ducting outboard side
forward of the #2 main engine air receiver is wasted and
holed.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. L/O drain tank stbd side lower
level is missing a flange on the side of the tank
allowing tank contents to drain in the bilge.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. There is a soft patch in the tee
fitting for the MDE air cooler chemical cleaning pump
piping.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The MDE air cooler chemical
cleaning tank is missing a flange on the side of the
tank, and the tank bottom is scaled.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The waste heat boiler easing gear
is not accessible.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 31 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. Cooler outboard side of the air
compressor mid level e/r has pin hole leak in the s/w
piping.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The following MDE fuel lines needs
replacing as per OEM guidance due to outer braided layer
being compromised;
#1 cylinder center f/o line
#2 cylinder forward f/o line
#4 cylinder forward f/o line.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 31 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The s/w outlet piping for the MDE
j/w cooler mid-level stbd side forward is holed.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The flange hardware for the 5” pipe
off the sea chest supplying the a/c s/w pump suction
manifold sea strainer are wasted, and the 90 degree
elbow is corroded on the underside.
74 SOLAS(20) I/11 Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 31 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The #3SSDG has a pin hole leak in
the s/w piping outboard side.
74 SOLAS(20) I/11(a) action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. MDE scavenge box #1 has a soft
patch above the bullseye sight glass and another soft
patch below the bullseye sight glass.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The quick closing valve for the aft
cylinder l/o storage tank will not open. Testing of the
quick closing valve operation was not available.
74 SOLAS(20) I/11(a) Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 31 October 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 September 2023
Resolved
Cargo vessels as defined by Title 46 CFR, must maintain
portable and semi portable fire extinguishers in
accordance with 46 CFR 95.50-10, as required by ACP U.S.
Supplement 2021. Found portable extinguishers throughout
the vessel not marked with a number and the location
where stored is not marked with a corresponding number
at least ½” in height.
ACP Single U.S.Supplement 2021,3.1.2.10 Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 23 October 2023
Resolution: Cleared by ABS and CG
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 September 2023
Resolved
The company and the ship shall comply with the
requirements of the International Safety management
Code. The company should establish procedures, plans and
instructions, including checklists as appropriate, for
key shipboard operations concerning the safety of the
personnel, ship, and protection of the environment.
Found numerous vital system critical gauges that were
rejected, and/or out of calibration.
74 SOLAS(20)IX/3.1 ISM Action Code: ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2023
Resolution: Cleared by ABS and CG
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 19 September 2023
Resolved
Other means of embarkation may be permitted for the
liferafts required by reg. 26.1.4.
A suitable means of embarkation for the six man liferaft
positioned at the stern was not provided.
74 SOLAS (97) III/11.7 Action Code: ac
705 (other)= Rectify prior to completion of upcoming
repair period.
Action required: 705 - Other - as specified
Due 19 December 2023
Resolved 31 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 19 September 2023
Resolved
All lifesaving appliances shall be in working order and
ready for immediate use. The six man liferaft positioned
at the stern is not positioned so as to be readily
deployable because of fixed rails.
74 SOLAS (20)III/20.2 Action Code: ac
705 (other)= Rectify prior to completion of upcoming
repair period.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2023
Resolved 31 October 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 September 2023
Resolved
Electrical installations shall be such that the safety
of passengers, crew and ship from electrical hazards
will be ensured. Conduit located on the uppermost deck,
containing high voltage cables for control systems, is
substantially wasted.
74 SOLAS (04) II-1/40.1.3
705(other)= Rectify prior to completion of upcoming
repair period.
Action required: 705 - Other - as specified
Due 19 December 2023
Resolved 31 October 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 September 2023
Resolved
Containers, brackets, racks, and other similar stowage
locations for life-saving equipment shall be marked with
symbols in accordance with the recommendations of the
Organization (refer to IMO Resolution A.760(18) as
amended) indicating the devices stowed in that location
for that purpose. Signage is not present indicated the
stowage positions of the lifeboat radios or the EPIRB.
74 SOLAS (20) III/20.10
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 September 2023
Resolved
Where davit arms are recovered by power, safety devices
shall be fitted which will automatically cut off the
power before the davit arms reach the stops.
Limit switches on port lifeboat davit failed to arrest
power before the davit arms reached the stops.
74 SOLAS (97) III/48.2.5,
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2023
Resolved
The following fire protection systems shall be kept in
good order so as to ensure their required performance if
a fire occurs: fire detection and fire alarm systems.
Three fixed smoke detectors above the SSDG’s are covered
with plastic bags.
74SOLAS(20 Con) II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 September 2023
Resolved
The following fire protection systems shall be kept in
good order so as to ensure their required performance if
a fire occurs: structural fire protection, including
fire-resisting divisions, and protection of openings and
penetrations in these divisions. The self-closing door
in front of the waste boiler does not latch preventing
it from fully closing.
74 SOLAS(20) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 19 September 2023
Resolved
The following fire protection systems shall be kept in
good order so as to ensure their required performance if
a fire occurs: structural fire protection, including
fire-resisting divisions, and protection of openings.
The purifier room ventilation damper will not completely
close.
74 SOLAS(20) II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The improper stowage of gear in
steering gear space is preventing access to the hyper
mist system.
74 SOLAS(20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The #3SSDG l/o psi alarm isolation
valve snapped off.
74 SOLAS(20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2023
Resolved
The condition of the ship and its equipment shall be
maintained to conform with the provisions of the present
regulations to ensure that the ship in all respects will
remain fit to proceed to sea without danger to the ship
or persons on board. The cable for the satellite that
was disconnected from the installed batteries was not
removed and is hanging.
74SOLAS(20) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 21 December 2021
Resolved
Each survival craft shall be stowed fully equipped as required by this chapter. The starboard lifeboat was missing a required flare.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 December 2022
Resolved 21 December 2021
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 21 December 2021
Resolved
The steering gear compartments shall be provided with suitable arrangements to ensure working access to steering gear machinery and controls. These arrangements shall include handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. There were no gratings or other nonslip surfaces in the steering gear room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 December 2022
Resolved 21 December 2021