Records from 2005 to 2025. Most recent: inspection, 9 June 2025.
Inspection history · 36
9 June 2025
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8157189
3 June 2025
COC-CHEM Renew · PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8148601
6 January 2025
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8058683
6 January 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8058936
20 May 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7914030
24 May 2023
PSC B · COC-CHEM Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7693830
8 September 2022
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7555049
18 May 2022
PSC B · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7453525
19 May 2021
Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7198903
8 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7137330
12 June 2020
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6973869
4 October 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6828449
31 May 2019
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6696948
10 June 2018
Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6439372
16 May 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-CHEM & TVE Renew · MARPOL Annex V Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6143770
22 March 2017
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6132307
14 December 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6057801
18 April 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5856420
16 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5815650
18 December 2015
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5784626
16 August 2014
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4956686
7 May 2014
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4852756
18 December 2011
MARPOL Annex V Examination · COC-CHEM Renew · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4207913
22 November 2010
ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3895305
17 April 2009
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3452966
19 November 2008
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3363545
22 April 2008
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3191953
9 November 2007
COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3095910
28 June 2007
NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2976853
21 March 2007
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2892221
5 February 2007
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2867671
25 October 2006
Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · ILO-147 Exam · MARPOL Annex V Examination · COC-TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2807663
6 June 2006
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2703507
12 May 2006
NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2647367
9 October 2005
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2510075
9 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2515918
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 June 2025
Resolved
At least two blowers shall be fitted and be capable of delivering to the cargo tanks at least the volume of gas required by 2.2.1.2. #2 Blower had open outstanding condition of class due to unoperational #2 blower. Vessel crew repaired #2 blower. Provide class report attesting to satisfactory repair.
Cite: SOLAS 20 II-2/4.5.5.1.1 (FSS Code 15.2.3.1.3)
Action Taken: 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 June 2025
Resolution: Vessel sent in Class Final Attendance Report, clearing the outstanding condition of class for the IG Blower.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2025
Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. [name withheld] reported to the Port State Control Officer that the vessel could not go astern the first five tries while conducting a steering gear test prior to departure. PSCO is requiring a class report, prior to departure, attesting to the proper operation of the propulsion machinery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2025
Resolution: Class provided a For Action Report attesting to repairs made onboard the ship to a 3-way pneumatic valve that was not functioning properly. Repairs were made and machinery operated normally.
Construction/Loadline › Markings › Load Line Mark
Issued 12 June 2018
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The deck line was painted the same color as the hull.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 June 2018
Resolved 12 June 2018
Resolution: The deck line was painted white.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 June 2018
Resolved
Each Vessel vapor connection flange face must have a permanent stud projecting outward. The port side vapor connection flanges, foward and aft, have removable bolts instead of studs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 June 2018
Resolved 14 June 2018
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 28 June 2007
Resolved
Inert Gas System not providing volumetric flow required to maintain required oxygen levels in cargo tanks during full cargo discharge. Request class attest to proper operation of Inert Gas System.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 July 2007
Resolution: Lloyd''s Register came onboard and verified that the IGS was operating correctly.
Engineering › Compressed Air System (start air) › Compressor
Issued 6 February 2007
Resolved
No. 2 Start Air Compressor is not operational and is in the process of being replaced.
*Note* : Due to a sudden change of scheduling routes after deficiency was issued, the ship may/may not be able to have the deficiency repaired by next U.S. port after sailing foreign as specified in the deficiency report.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 21 March 2007
Resolution: Recived, from Class, documentation that the No.2 Start Air Compressor has been repaired and inspected.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 9 October 2005
Resolved
Provide a cross-index list or oil transfer procedures in the proper order IAW 33 CFR 155.750 to the satisfaction of the local OCMI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 14 October 2005
Resolution: Master ammended current Oil Transfer Procedures as per 33 CFR 155.750
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 9 October 2005
Resolved
Provide a muster list identifying special duties assigned in respect to the use of fire fighting equipment and inspections to the satisfaction of the local [name withheld] 74 AM. III-37-3.8
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 24 October 2005
Resolved 17 October 2005
Resolution: Master ammended current Emergency Muster List to reflect special duties required by crew in the event of a fire onboard.