MAURY USCG vessel records
← All vessels

ACADIAN

ACADIAN is a 2005 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in June 2025, along with 4 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 9 June 2025.

Built
2005
Last inspected
9 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 June 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9298715
CFH8964
793459
Flag
CANADA
Maury page id
psix-793459

Documentation record

Tonnage as PSIX records it23356 - Convention (Subpart B), Gross Ton
23356 - Regulatory (Subpart C or D), Gross Ton
10119 - Convention (Subpart B), Net Ton
10119 - Regulatory (Subpart C or D), Net Ton
45972 - Displacement, Ton
37515 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; 2 vessels inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FOURNIER GIRLS Towing Vessel · MISLE 98859 · 22 March 2017 · activity 6132307ROWAN M MCALLISTER Towing Vessel · MISLE 196450 · 22 March 2017 · activity 6132307

Inspection history · 19

9 June 2025 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8157189
3 June 2025 COC-CHEM Renew · PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8148601
6 January 2025 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8058683
6 January 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8058936
20 May 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7914030
24 May 2023 PSC B · COC-CHEM Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7693830
8 September 2022 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7555049
18 May 2022 PSC B · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7453525
19 May 2021 Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7198903
8 February 2021 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7137330
12 June 2020 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6973869
4 October 2019 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6828449
31 May 2019 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6696948
10 June 2018 Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6439372
16 May 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-CHEM & TVE Renew · MARPOL Annex V Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6143770
22 March 2017 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6132307
14 December 2016 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6057801
18 April 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5856420
16 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5815650

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 June 2025 Resolved
At least two blowers shall be fitted and be capable of delivering to the cargo tanks at least the volume of gas required by 2.2.1.2. #2 Blower had open outstanding condition of class due to unoperational #2 blower. Vessel crew repaired #2 blower. Provide class report attesting to satisfactory repair. Cite: SOLAS 20 II-2/4.5.5.1.1 (FSS Code 15.2.3.1.3) Action Taken: 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 June 2025
Resolution: Vessel sent in Class Final Attendance Report, clearing the outstanding condition of class for the IG Blower.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2025 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. [name withheld] reported to the Port State Control Officer that the vessel could not go astern the first five tries while conducting a steering gear test prior to departure. PSCO is requiring a class report, prior to departure, attesting to the proper operation of the propulsion machinery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2025
Resolution: Class provided a For Action Report attesting to repairs made onboard the ship to a 3-way pneumatic valve that was not functioning properly. Repairs were made and machinery operated normally.
Construction/Loadline › Markings › Load Line Mark
Issued 12 June 2018 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The deck line was painted the same color as the hull.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 June 2018
Resolved 12 June 2018
Resolution: The deck line was painted white.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 June 2018 Resolved
Each Vessel vapor connection flange face must have a permanent stud projecting outward. The port side vapor connection flanges, foward and aft, have removable bolts instead of studs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 June 2018
Resolved 14 June 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.