MAURY USCG vessel records Sign in
← All vessels

ACADIAN

ACADIAN is a 2005 tank ship. The Coast Guard has recorded 36 inspections since 2005, most recently in June 2025, along with 8 deficiencies and 2 operational controls.

Records from 2005 to 2025. Most recent: inspection, 9 June 2025.

Built
2005
Last inspected
9 June 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9298715 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
CFH8964
793459
Flag
CANADA
—
Maury page id
psix-793459

Inspections, by type

…with no type recorded6
Years with a record 19 calendar years (2005–2025)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23356 - Convention (Subpart B), Gross Ton
23356 - Regulatory (Subpart C or D), Gross Ton
10119 - Convention (Subpart B), Net Ton
10119 - Regulatory (Subpart C or D), Net Ton
45972 - Displacement, Ton
37515 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FOURNIER GIRLS Towing Vessel · MISLE 98859 · 22 March 2017 · activity 6132307ROWAN M MCALLISTER Towing Vessel · MISLE 196450 · 22 March 2017 · activity 6132307

Inspection history · 36

9 June 2025 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8157189
3 June 2025 COC-CHEM Renew · PSC B
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8148601
6 January 2025 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8058683
6 January 2025 In-Service Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8058936
20 May 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7914030
24 May 2023 PSC B · COC-CHEM Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7693830
8 September 2022 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7555049
18 May 2022 PSC B · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7453525
19 May 2021 Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7198903
8 February 2021 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7137330
12 June 2020 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6973869
4 October 2019 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6828449
31 May 2019 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6696948
10 June 2018 Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6439372
16 May 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-CHEM & TVE Renew · MARPOL Annex V Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6143770
22 March 2017 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6132307
14 December 2016 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6057801
18 April 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5856420
16 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5815650
18 December 2015 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5784626
16 August 2014 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4956686
7 May 2014 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4852756
18 December 2011 MARPOL Annex V Examination · COC-CHEM Renew · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4207913
22 November 2010 ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3895305
17 April 2009 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3452966
19 November 2008 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3363545
22 April 2008 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3191953
9 November 2007 COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3095910
28 June 2007 NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2976853
21 March 2007 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2892221
5 February 2007 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2867671
25 October 2006 Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · ILO-147 Exam · MARPOL Annex V Examination · COC-TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2807663
6 June 2006 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2703507
12 May 2006 NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2647367
9 October 2005 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2510075
9 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2515918

Deficiency record · 8

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 June 2025 Resolved
At least two blowers shall be fitted and be capable of delivering to the cargo tanks at least the volume of gas required by 2.2.1.2. #2 Blower had open outstanding condition of class due to unoperational #2 blower. Vessel crew repaired #2 blower. Provide class report attesting to satisfactory repair. Cite: SOLAS 20 II-2/4.5.5.1.1 (FSS Code 15.2.3.1.3) Action Taken: 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 June 2025
Resolution: Vessel sent in Class Final Attendance Report, clearing the outstanding condition of class for the IG Blower.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 January 2025 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. [name withheld] reported to the Port State Control Officer that the vessel could not go astern the first five tries while conducting a steering gear test prior to departure. PSCO is requiring a class report, prior to departure, attesting to the proper operation of the propulsion machinery.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 January 2025
Resolution: Class provided a For Action Report attesting to repairs made onboard the ship to a 3-way pneumatic valve that was not functioning properly. Repairs were made and machinery operated normally.
Construction/Loadline › Markings › Load Line Mark
Issued 12 June 2018 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. The deck line was painted the same color as the hull.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 June 2018
Resolved 12 June 2018
Resolution: The deck line was painted white.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 10 June 2018 Resolved
Each Vessel vapor connection flange face must have a permanent stud projecting outward. The port side vapor connection flanges, foward and aft, have removable bolts instead of studs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 June 2018
Resolved 14 June 2018
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 28 June 2007 Resolved
Inert Gas System not providing volumetric flow required to maintain required oxygen levels in cargo tanks during full cargo discharge. Request class attest to proper operation of Inert Gas System.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 July 2007
Resolution: Lloyd''s Register came onboard and verified that the IGS was operating correctly.
Engineering › Compressed Air System (start air) › Compressor
Issued 6 February 2007 Resolved
No. 2 Start Air Compressor is not operational and is in the process of being replaced. *Note* : Due to a sudden change of scheduling routes after deficiency was issued, the ship may/may not be able to have the deficiency repaired by next U.S. port after sailing foreign as specified in the deficiency report.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 March 2007
Resolved 21 March 2007
Resolution: Recived, from Class, documentation that the No.2 Start Air Compressor has been repaired and inspected.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 9 October 2005 Resolved
Provide a cross-index list or oil transfer procedures in the proper order IAW 33 CFR 155.750 to the satisfaction of the local OCMI.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 14 October 2005
Resolution: Master ammended current Oil Transfer Procedures as per 33 CFR 155.750
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 9 October 2005 Resolved
Provide a muster list identifying special duties assigned in respect to the use of fire fighting equipment and inspections to the satisfaction of the local [name withheld] 74 AM. III-37-3.8
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 24 October 2005
Resolved 17 October 2005
Resolution: Master ammended current Emergency Muster List to reflect special duties required by crew in the event of a fire onboard.

Ownership record