MAURY USCG vessel records
← All vessels

FOURNIER GIRLS

FOURNIER GIRLS is a 1968 towing vessel. The Coast Guard has recorded 31 inspections since 1988, most recently in February 2022, along with 35 deficiencies — 1 with no resolution recorded — and 4 casualty investigations between 1996 and 2017.

Records from 1988 to 2022. Most recent: inspection, 8 February 2022.

Built
1968
Last inspected
8 February 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

6921359
WDD4563
Flag
UNITED STATES
Maury page id
psix-98859

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded18
…past their stated due date1
Years with a record 19 calendar years (1988–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it198 - Regulatory (Subpart C or D), Gross Ton
135 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 5

Inspection history · 31

8 February 2022 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7392327
14 July 2021 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7238083
24 May 2021 Initial Certification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7205696
11 July 2019 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6745717
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6538120
22 March 2017 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6132307
17 March 2016 Industry Initiated Exam · MTSA Verification · Administration
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5801584
27 February 2013 MTSA Verification · Industry Initiated Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4541610
29 March 2011 DAPI Audit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3986520
26 January 2011 Uninspected Other
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3933331
4 December 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3110447
30 October 2006 MTSA Verification
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2810461
20 August 2006 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2762779
29 April 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2064095
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973055
26 February 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 37287
17 August 1998 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 795901
15 May 1998 Uninspected Towing Vessel
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1424588
19 January 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 64593
16 November 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 125090
31 July 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 205675
31 July 1995 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 760401
23 July 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 145873
17 June 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 21932
5 March 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 100424
22 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 180135
4 January 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 670191
24 August 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 140586
28 July 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 176612
10 April 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 6580
22 February 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330606

Deficiency record · 35

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 May 2021 Resolved
Vessel could not provide proof of Annual testing of fire detection system.
Due 24 June 2021
Resolved 10 December 2021
Resolution: Vessel scrapped
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 May 2021 Resolved
Smoke detectors in accomodation spaces are not UL 217 approved.
Due 24 June 2021
Resolved 10 December 2021
Resolution: Vessel scrapped
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2021 Resolved
Vessel needs a dry dock to come into compliance with Sub M.
Due 1 July 2021
Resolved 10 December 2021
Resolution: Vessel scrapped
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Crew could not demonstrate proper operation of low level alarms for steering.
Due 24 June 2021
Resolved 10 December 2021
Resolution: Vessel scrapped
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Air receiver relief valves need tested.
Due 24 June 2021
Resolved 10 December 2021
Resolution: Vessel scrapped
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2021 Resolved
Air receivers need an internal inspection.
Due 24 June 2021
Resolved 10 December 2021
Resolution: Vessel scrapped
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 No resolution recorded
The vessel is currently broadcasting (1) Improper IMO Number. The IMO number should have the two zeros preceding the number to create a nine digit number. Should not add the two zero’s at the end of the 7 digit number.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2018 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 29 March 2011 Resolved
Company does not have background check form as required by 49 CFR 40.25
Action required: 705 - Other - as specified
Due 28 April 2011
Resolved 29 March 2011
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 29 March 2011 Resolved
Company cannot prove that alcohol screening devices are approved in accordance with 46 CFR 4.06-15(a)(2)
Action required: 705 - Other - as specified
Due 28 April 2011
Resolved 29 March 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 March 2011 Resolved
Company does not have proof of supervisor EAP training as required by 46 CFR 16.401(b).
Action required: 705 - Other - as specified
Due 28 April 2011
Resolved 19 July 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 January 2011 Resolved
Ring buoy light would not light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: New ring buoy light battery installed and tested
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 January 2011 Resolved
Master did not provide a current license
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2011
Resolved 26 January 2011
Resolution: Master found his license
Lifesaving › Immersion Suits › General
Issued 26 January 2011 Resolved
Light and whistle missing from survival suit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: New light and whistle placed on suit as required
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 26 January 2011 Resolved
Provide tank capacity for lube oil and hydraulic oil tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 25 January 2012
Resolution: Capacity of tanks received.
Documentation › Markings/Placards › Warning Signs
Issued 26 January 2011 Resolved
Post employee assistance program placard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2011
Resolved 26 January 2011
Resolution: Crew posted correct placard as required
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 26 January 2011 Resolved
Post oil transfer procedures
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Oil transfer procedures posted as required
Electrical › Lighting (service) › Lighting Fixture
Issued 26 January 2011 Resolved
Repair broken capstan light lens
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Light fixture repaired as required
Fire Fighting › Fire Hydrants › Condition
Issued 26 January 2011 Resolved
provide required equipment at the stbd fire station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Equipment provided as required
Fire Fighting › Fire Pumps › Location
Issued 26 January 2011 Resolved
label remote fire pump switch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Remote fire pump switch labeled as required
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 26 January 2011 Resolved
Remove all waste oil from bilges and clean
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Oil removed as required and bilges cleaned
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2011 Resolved
Repair deck over reduction gear
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 25 January 2012
Resolution: New deck plate welded in place.
Engineering › Steam System (auxiliary) › Piping
Issued 26 January 2011 Resolved
provide insulation on hot water piping from boiler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Insulation installed as required
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 January 2011 Resolved
Repair and test aft steering bilge alarm
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Alarm repaired and tested as required
Fire Fighting › Fire Main › Condition
Issued 26 January 2011 Resolved
Renew 3ft section of firemain in upper level of engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: New fireman piping section installed as required
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 January 2011 Resolved
Repair, replace vessel wiring identified through out vessel, ensure proper hanging attachment points and remove any and all dead end wires throughout vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 25 January 2012
Resolution: Wiring repaired or removed where necessary.
Engineering › Fuel Oil Service System › Hose
Issued 26 January 2011 Resolved
Seal ends of fuel hose fire jacklet as required on fuel hoses
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 25 January 2012
Resolution: New hoses and fittings installed.
Construction/Loadline › Structures › Deck Plating
Issued 26 January 2011 Resolved
Repair deck stbd side engine room behind SSG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 25 January 2012
Resolution: Deck repaired.
Fire Fighting › Fire Pumps › Pressure
Issued 26 January 2011 Resolved
Renew fire pump pressure gauge and provide proof pump can attain 50psi capacity
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: New fire pump installed and tested as required
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 January 2011 Resolved
Provide a proper machinery guard for engine PTO
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Guard installed as required
Engineering › Steering Gear System › Rudder Bearing
Issued 26 January 2011 Resolved
Renew rudder packing and stop excessive leak on all rudders
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: New packing installed and adjusted
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 26 January 2011 Resolved
Conduct maintenance of emergency escape scuttle in aft steeering
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 July 2011
Resolved 29 June 2011
Resolution: Maintenance condusted as required, scuttle works properly
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 26 January 2011 Resolved
Vessel currently has a Hiller SAFE detection panel installed. Vessel informed to meet standards of 46 CFR 27.203(a), as per headquarters guidance, by 01 January 2013.
Action required: 705 - Other - as specified
Due 1 January 2013
Resolved 18 September 2012
Resolution: New MIRCOM FA-300 fire detection panel installed and approved by a PE, Certificate received and placed into local file.
Navigation
Issued 15 May 1998 Resolved
STERN LIGHT OBSCURED BY VESSEL NAME PLATE
Condition: Unknown
Due 15 May 1998
Resolved 18 May 1998
Fire Fighting
Issued 15 May 1998 Resolved
ONE FIRE EXTINGUISHER NEEDS RECHARGING.
Condition: Unknown
Due 15 May 1998
Resolved 18 May 1998
Navigation
Issued 15 May 1998 Resolved
HYDRAULIC HOSE ON STEERING GEAR WORN.
Condition: Unknown
Due 15 May 1998
Resolved 18 May 1998

Casualty record · 4

19 January 1996Major Marine Casualty · role: Involved in a Marine Casualty · activity 64593
29 April 2004Routine · role: Involved in a Marine Casualty · activity 2064095
20 August 2006Routine · role: Involved in a Marine Casualty · activity 2762779
22 March 2017Routine · role: Involved in a Marine Investigation (non-casualty) · activity 6132307
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.