Records from 2005 to 2024. Most recent: operational control imposed, 23 October 2024.
Inspection history · 23
23 October 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8024345
21 September 2024
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8006528
15 March 2022
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7412125
3 May 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7188546
19 February 2021
COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7143052
13 March 2020
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925906
12 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925402
8 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6922443
25 February 2019
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6628811
27 February 2018
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6362539
3 February 2018
Deficiency Check · Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6348069
13 October 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6286811
12 June 2017
COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6169566
9 June 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6170857
18 January 2017
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6127567
11 January 2017
ISPS II Exam · COC-CHEM & TVE Renew · COE-Offshore · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6069246
6 September 2015
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5236397
28 May 2014
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4869880
6 February 2007
ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2867980
2 August 2006
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2734435
10 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2532407
5 November 2005
MARPOL Annex V Examination · ISPS II Exam · COC-CHEM Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2528776
5 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2528787
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 March 2020
Resolved
Tankers fitted with an inert gas system shall be provided with a closed ullage system. The ullage sensor on the no. 3 starboard cargo tank is inoperable and shows an inaccurate reading. Must be repaired prior to loading cargo.
cite: 74 SOLAS (14) II-2/4.5.5.3
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2020
Resolved 20 February 2021
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 February 2019
Resolved
Parties responsible for fir extinguishing shall be organized. These parties shall have the capacity to complete their duties at all times while the ship is in service (15.2.1.3). Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire fighting systems and appliances that they may be called upon to use (15.2.2.1).
PSCO observed crewman improperly donning SCBA mask, allowing air to escape due to improper seal of mask. Crewman then approached fire engaged in fire fighting efforts with no air pressure left in bottle. Additionally, crew attempted to fight simulated oil fire on cargo deck with fire hose connected to fire hydrant instead of foam applicator to foam line.
74 SOLAS (14) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2019
Resolved 25 February 2019
Resolution: PSCO subsequently observed second fire drill to the satisfaction of the PSCO.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 3 February 2018
Resolved
Multiple areas of corrosion and leaking were found on the inert gas cooling line and inert gas cooling drain line. (74 SOLAS II-2/4.5.5.3.2). Prior to conducting cargo.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2018
Resolved 5 February 2018
Resolution: Crew replaced leaking portions of pipe.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 3 February 2018
Resolved
Main supply pump to deck water seal was found to be corroded and leaking where supply line exits engine room. (74 SOLAS II-2/4.5.5.3.2) Prior to conducting cargo.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2018
Resolved 5 February 2018
Resolution: Crew inspected corroded flange area and found the gasket wasted. Gasket replaced.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 3 February 2018
Resolved
The gas sampling main pump for the void and ballast spaces was found to be inoperable. (74 SOLAS II-2/4.5.7.2.2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2018
Resolved 3 February 2018
Resolution: Crew repaired and brought pump back into service.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 3 February 2018
Resolved
The infrared sensor for the gas detection equipment was found out of calibration and requires manufacturer servicing per the manufacturers manual. (74 SOLAS II-2/4.5.7.2.2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 27 February 2018
Resolution: Received class report attesting to proper servicing/calibration.
Engineering › Steam System (auxiliary) › Piping
Issued 3 February 2018
Resolved
Scupper line on boiler deck outside containment found leaking. (74 SOLAS I-11)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 5 February 2018
Resolution: Crew replaced pipe.
Construction/Loadline › Structures › Door
Issued 3 February 2018
Resolved
Wasted metal door frame leading into engine room funnel from port side ventilation. (74 SOLAS I-11)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 27 February 2018
Resolution: Received class report attesting to proper repairs.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 February 2018
Resolved
Modified ventilation ducting is installed on lube oil pump and compressor control unit in engine room. (74 SOLAS II-1/35)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 27 February 2018
Resolution: Received class report attesting to removal of temporary ducting.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 3 February 2018
Resolved
Grounding wire for the fuel oil supply pump number one was found unattached within the purifier room. Wiring for the number two supply pump within the purifier room found frayed.(74 SOLAS II-1/45.5.5)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2018
Resolved 3 February 2018
Resolution: Crew attached grounding wire and replaced frayed wire.
Fire Fighting › Structural - A Class Divisions › Workshops
Issued 3 February 2018
Resolved
A grinding workshop was found within the air conditioning room which is not classified as a high risk service space. (74 SOLAS II-2/9.2.4.2.2.2(9)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2018
Resolved 3 February 2018
Resolution: Crew removed grinder from space.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 November 2005
Resolved
Deck covering in the engine control room has lifted and buckeled which poses a high risk of tripping. Make the decking flat so not to pose a tripping hazard. Repair by 05Dec05 to the satisfaction of the Administration.
Action required: 705 - Other - as specified
Due 5 December 2005
Resolved 2 August 2006
Resolution: The deck covering in the engine control room has now been renewed and found satisfactory in accordance with the vessel''s classification society.