TORM RAGNHILD

TORM RAGNHILD is a 2005 tank ship. The Coast Guard has recorded 16 inspections since 2017, most recently in October 2024, along with 11 deficiencies and 6 operational controls.

Records from 2017 to 2024. Most recent: operational control imposed, 23 October 2024.

Built
2005
Last inspected
23 October 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 October 2024
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9290579
796977
Flag
DENMARK
Maury page id
psix-796977

Documentation record

Tonnage as PSIX records it56364 - Displacement, Metric Ton
46187 - Dead Weight, Metric Ton
30180 - Convention (Subpart B), Gross Ton
11781 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 6 operational controls with the dates imposed and removed; 1 vessel inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAERSK HARTFORD Freight Ship · MISLE 1101124 · 18 January 2017 · activity 6127567

Inspection history · 16

23 October 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8024345
21 September 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8006528
15 March 2022 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7412125
3 May 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7188546
19 February 2021 COC-TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7143052
13 March 2020 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925906
12 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925402
8 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6922443
25 February 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6628811
27 February 2018 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6362539
3 February 2018 Deficiency Check · Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6348069
13 October 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6286811
12 June 2017 COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6169566
9 June 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6170857
18 January 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6127567
11 January 2017 ISPS II Exam · COC-CHEM & TVE Renew · COE-Offshore · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6069246

Deficiency record · 11

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 13 March 2020 Resolved
Tankers fitted with an inert gas system shall be provided with a closed ullage system. The ullage sensor on the no. 3 starboard cargo tank is inoperable and shows an inaccurate reading. Must be repaired prior to loading cargo. cite: 74 SOLAS (14) II-2/4.5.5.3
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 March 2020
Resolved 20 February 2021
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 February 2019 Resolved
Parties responsible for fir extinguishing shall be organized. These parties shall have the capacity to complete their duties at all times while the ship is in service (15.2.1.3). Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire fighting systems and appliances that they may be called upon to use (15.2.2.1). PSCO observed crewman improperly donning SCBA mask, allowing air to escape due to improper seal of mask. Crewman then approached fire engaged in fire fighting efforts with no air pressure left in bottle. Additionally, crew attempted to fight simulated oil fire on cargo deck with fire hose connected to fire hydrant instead of foam applicator to foam line. 74 SOLAS (14) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 February 2019
Resolved 25 February 2019
Resolution: PSCO subsequently observed second fire drill to the satisfaction of the PSCO.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 3 February 2018 Resolved
Multiple areas of corrosion and leaking were found on the inert gas cooling line and inert gas cooling drain line. (74 SOLAS II-2/4.5.5.3.2). Prior to conducting cargo.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2018
Resolved 5 February 2018
Resolution: Crew replaced leaking portions of pipe.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 3 February 2018 Resolved
Main supply pump to deck water seal was found to be corroded and leaking where supply line exits engine room. (74 SOLAS II-2/4.5.5.3.2) Prior to conducting cargo.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2018
Resolved 5 February 2018
Resolution: Crew inspected corroded flange area and found the gasket wasted. Gasket replaced.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 3 February 2018 Resolved
The gas sampling main pump for the void and ballast spaces was found to be inoperable. (74 SOLAS II-2/4.5.7.2.2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2018
Resolved 3 February 2018
Resolution: Crew repaired and brought pump back into service.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 3 February 2018 Resolved
The infrared sensor for the gas detection equipment was found out of calibration and requires manufacturer servicing per the manufacturers manual. (74 SOLAS II-2/4.5.7.2.2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 27 February 2018
Resolution: Received class report attesting to proper servicing/calibration.
Engineering › Steam System (auxiliary) › Piping
Issued 3 February 2018 Resolved
Scupper line on boiler deck outside containment found leaking. (74 SOLAS I-11)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 5 February 2018
Resolution: Crew replaced pipe.
Construction/Loadline › Structures › Door
Issued 3 February 2018 Resolved
Wasted metal door frame leading into engine room funnel from port side ventilation. (74 SOLAS I-11)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 27 February 2018
Resolution: Received class report attesting to proper repairs.
Accommodation/Occupational Safety › Ventilation › General
Issued 3 February 2018 Resolved
Modified ventilation ducting is installed on lube oil pump and compressor control unit in engine room. (74 SOLAS II-1/35)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 27 February 2018
Resolution: Received class report attesting to removal of temporary ducting.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 3 February 2018 Resolved
Grounding wire for the fuel oil supply pump number one was found unattached within the purifier room. Wiring for the number two supply pump within the purifier room found frayed.(74 SOLAS II-1/45.5.5)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2018
Resolved 3 February 2018
Resolution: Crew attached grounding wire and replaced frayed wire.
Fire Fighting › Structural - A Class Divisions › Workshops
Issued 3 February 2018 Resolved
A grinding workshop was found within the air conditioning room which is not classified as a high risk service space. (74 SOLAS II-2/9.2.4.2.2.2(9)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 February 2018
Resolved 3 February 2018
Resolution: Crew removed grinder from space.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.