Records from 2005 to 2021. Most recent: inspection, 15 April 2021.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · MADISONVILLE, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Net Ton
1619 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
15 April 2021
COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7175564
20 March 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6388776
28 June 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6223501
5 April 2016
Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5847097
9 March 2016
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5832562
13 February 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5077865
25 February 2014
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4802736
18 June 2013
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4624299
25 September 2012
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4450568
11 April 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4287750
8 February 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4263797
2 January 2011
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3932580
3 December 2010
COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3902822
3 December 2010
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3902847
22 March 2010
Type not recorded
No type recorded · Investigations National Center of Expertise · Activity 3705665
4 January 2010
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3706185
4 February 2008
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3141436
8 September 2007
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3059520
17 July 2007
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2998054
13 March 2007
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2887328
12 March 2007
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2886158
22 February 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2879796
18 December 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2842681
14 July 2006
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2712443
10 July 2006
Damage Survey
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2707784
14 June 2006
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2679666
3 April 2006
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2615275
8 February 2006
COI Inspection · Cargo Tank Internal · MTSA Verification · Internal Structural Exam · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2581739
22 December 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2555192
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 28 June 2017
Resolved
Pump engine would not shut down when EMS cable pulled
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2017
Resolution: Air flap for shutdown was replaced
Engineering › Fuel Oil Service System › Hose
Issued 25 February 2014
Resolved
Remove unauthorized fuel hoses on Thermal Fluid Generator and install Coast Guard approved fuel hoses. 46CFR56.60-25(b)
Action required: 705 - Other - as specified
Due 1 March 2014
Resolved 27 February 2014
Resolution: Verified SAE J1942 hoses were installed.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 25 February 2014
Resolved
Install lagging on exhaust of Prime mover. 46CFR56.50-1(k)
Action required: 705 - Other - as specified
Due 1 March 2014
Resolved 27 February 2014
Resolution: Verified lagging is installed on exhaust prime mover.
Construction/Loadline › Hull › Bottom Plating
Issued 12 March 2007
Resolved
Make repairs to Port Push Knee (1.5" x 2" hole) and gas free bow rake, make available to Coast Guard inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2007
Resolution: ALL REPAIRS INSPECTED AND COMPLETED
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2006
Resolved
Found cargo leak in the port side bow rake collision bulkhead, rolled floor frames with fractured welds and deformed corner brackets. Vessel is authorized to transit to Houston Fuel Oil Terminal to offload and return to a local Houston shipyard for permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2006
Resolved 19 July 2006
Resolution: Witnessed satisfactory repairs and air test of floor frames and brackets in bow rake void.
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2006
Resolved
Conducted a hull examination and an internal inspection of bow and stern section due to a recent grounding in Lake Providence, LA.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2007
Deck/Cargo › Cargo Heating › General
Issued 8 February 2006
Resolved
Insure all piping cargo and hot oil is insulated prior to loading cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2006
Resolution: ALL PIPING IS INSULATED.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 February 2006
Resolved
Provide Coast Guard approval letter for vessel response plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2006
Resolution: RECEIVED APPROVED PLAN
Deck/Cargo › Cargo Stowage › General
Issued 8 February 2006
Resolved
Provide approval for alternator and wiring harness for the sensors on the cargo pump prime mover to meet class I division I standards.
Due 30 August 2006
Resolved 30 March 2006
Resolution: WIRING HARNESS APPROVED