LKEY is a 2006 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in April 2026, along with 10 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 27 April 2026.

Built
2006
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9292759
806412
Flag
PANAMA
Maury page id
psix-806412

Documentation record

Tonnage as PSIX records it25994 - Convention (Subpart B), Gross Ton
7799 - Convention (Subpart B), Net Ton
29190 - Dead Weight, Metric Ton
41151 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

27 April 2026 PSC B · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8356319
29 March 2024 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7886303
28 April 2018 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6402272
23 April 2018 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6395138
27 December 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6329596
27 August 2017 COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6252712
25 August 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6251549
26 May 2017 COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6152455
19 April 2017 COE-Dockside
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6125982
23 January 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6075083
11 December 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6056496
7 December 2016 COE-Administrative
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6054228
6 November 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6036157
1 August 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5959705
23 April 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5860720
22 April 2016 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5855341
9 March 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5830264

Deficiency record · 10

Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 23 April 2018 Resolved
Gas detection equipment should be designed that it may readily be tested and suitable equipment for this purpose should be carried on board. PSCO were unable to witness satisfactory test of the ship's fixed gas detection system. During testing PSCO's witnessed 13 out of 17 sampling points that had readings of between 5% - 10% LEL for NH3. When introducing span gas of NH3 with a balance of nitrogen, LEL reading raised to 100% even though span gas is 5% NH3 by volume with a balance of nitrogen.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2018
Resolved 27 April 2018
Resolution: Vsl provided class report attesting to repair of fixed gas detection system.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 April 2018 Resolved
In zones on open decks over the cargo area and 3 M forward and aft of the cargo area where such is exposed to the weather, certified safe type equipment must be installed. Numerous lighting fixtures observed to have cracks through lenses and compromised gasket fixtures by way of FWD superstructure, aft motor room, aft of forecastle.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 23 April 2018
Resolved 28 April 2018
Resolution: Vessel recieved new lenses for lights.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 23 April 2018 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules. PSCO found a steady fuel leak on the #3 SSDG due to a wasted o-ring, several explosion proof lightfixtures were found cracked and compromised.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 28 April 2018
Resolution: Company set up new procedures and risk management analysis to rectify holes in pms on vessels equipment.
Engineering › Fuel Oil Service System › Piping
Issued 23 April 2018 Resolved
Means shall be provided to control leaks of flammable liquids. Substantial fuel leaks observed in the following locations in the machinery spaces on #3 SSDG, in purifier room, and from fuel supply line by #6 cylinder on Main Engine.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2018
Resolved 23 April 2018
Resolution: Engineers replaced o-ring on #3SSDG and tightened fittings securing fuel leak in purifier room and on main engine.
Lifesaving › Inflatable Liferafts › Painter
Issued 23 April 2018 Resolved
The life raft painter system shall provide a connection between the ship and the life raft and shall be so arranged as to ensure the life raft when released, and in the case of an inflatable life raft, inflated is not dragged under by the sinking ship. The starboard life raft observed with sea painter disconnected from ship inhibiting its float free readiness.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 April 2018
Resolved 23 April 2018
Resolution: 2nd officer reattached painter to weak link.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 23 April 2018 Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column F in the table of chapter 19. Ships fixed system does not measure NH3 PPM. Ships enclosed space entry permit requires PPM readings taken less than 50% TLV of specified cargo. Ships crew provided they enter the space with their personal gas meter. Both the fixed gas detection and personal gas meter does not protect the crew from entering a space so as not to be exposed from the TLV of product that is being carried onboard.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2018
Resolved 27 April 2018
Resolution: Vsl provided class report attesting to proper installation of system
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 23 April 2018 Resolved
Gas detection sample heads should be positioned with due regard to the density of the vapors. The gas detection sample head is in the airlock is located in the lower part of the space. The vessel carries ammonia whose vapors are lighter than air.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2018
Resolved 27 April 2018
Resolution: Vsl crew installed sample head in proper position.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 23 April 2018 Resolved
Airlock doors should be self-closing and without any hold backs arrangements. The airlock door on the weather deck is not self-closing.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 1 May 2018
Resolved 27 April 2018
Resolution: Vsl crew adjusted self-closing device and removed hold back hook.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 23 April 2018 Resolved
A warning notice requiring the use of ventlation should be outside the compressor room and motor room. Port State Control Officers could not identify a ventilation warning sign outside of the compressor or motor room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 27 April 2018
Resolution: Vsl crew installed warning sign outside spaces.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 26 May 2017 Resolved
1850:The condition of the ship and its equipment should be maintained to conform with the provisions of the Code to ensure the ship will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel could not provide documentation attesting to the fire rating of the cat walk deck grating. Deck grating n question is the only access to installed powder fire extinguishing system,
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 May 2017
Resolution: Received documentation attesting to approval and fire resistant ratings.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.