Records from 2006 to 2026. Most recent: inspection, 10 August 2026.
Inspection history · 19
10 August 2026
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8456731
22 June 2024
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7933469
23 November 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7594671
17 November 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7596096
19 December 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6326375
21 February 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5819137
20 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5818873
20 February 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5909299
2 February 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808082
7 October 2015
ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5735186
30 December 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3917774
26 September 2008
ISPS I Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3332694
27 August 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3302615
25 August 2008
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3308334
22 August 2008
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3305888
29 July 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2728906
26 February 2006
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2592253
25 February 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2591773
21 February 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2589072
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo ship safety equipment (including exemption)
Issued 10 August 2026
Resolved
When an exemption is granted to a ship under and in accordance with the provisions of the present regulations a certificate called an exemption certificate shall be issued in addition to the certificate.
PSCO observed the vessel did not have an exemption certificate listed in the Cargo Ship Safety Equipment certificate which states that the vessel is not required to have fixed fire fighting in its cargo holds.
74SOLAS I/12(a)(vii)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2026
Resolved 11 August 2026
Resolution: Class provided the vessel with the exemption certificate and sent a copy to the Coast Guard for verification. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 August 2026
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
PSCO observed 02 clogged nozzles for the fixed foam system in machinery space.
74SOLAS II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2026
Resolved 11 August 2026
Resolution: Corrected on the spot, engineers were able to clear the clogged nozzles and blow air through the system to test functionality.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2026
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
PSCO observed frayed wiring and unsafe splicing of wires in the ECR.
74SOLAS II-1/45.1.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2026
Resolved 11 August 2026
Resolution: Corrected on the spot, vessel removed the unsafe wiring and associated components.