MAURY USCG vessel records
← All vessels

NATHAN S

Built
1962
Last inspected
29 July 2025
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 29 July 2025
…with no type recorded31
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8841967
WDJ5413
Flag
UNITED STATES
Maury page id
psix-81517

Documentation record

Registered dimensions (L × B × D)90.5 ft × 28.5 ft × 12.4 ft
Registered tonnagegross 198 / net 135
ITC dimensions (L × B × D)90.5 ft × 28.5 ft × 12.4 ft
ITC tonnagegross 194 / net 58
BuilderMAIN IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1962
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 24 March 2025 · expires 30 April 2026
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it198 - Regulatory (Subpart C or D), Gross Ton
194 - Convention (Subpart B), Gross Ton
135 - Regulatory (Subpart C or D), Net Ton
58 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 61 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 9 other vessels inspected with it; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 9

Inspection history · 61

29 July 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8197296
25 November 2024 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8039863
28 August 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8006278
1 August 2024 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7971793
7 August 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7762616
18 July 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7745440
17 October 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7579236
31 August 2022 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7562701
16 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7535497
12 August 2022 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7531751
20 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7511723
27 May 2022 MTSA Verification · Initial Certification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7433105
20 December 2021 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7370615
31 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6429995
24 April 2018 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6398687
13 January 2018 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6346878
17 October 2017 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6289699
20 September 2013 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4721203
2 July 2013 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4640133
27 June 2013 Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4634414
4 February 2013 Spot Check (Safety)
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4529645
20 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4350448
7 May 2012 MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4304804
13 February 2012 DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4243805
24 November 2011 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4198745
25 June 2010 MARPOL · Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3794406
24 July 2009 Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3544781
5 March 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2914664
6 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2703569
29 June 2006 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2709112
13 June 2006 Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2678737
19 August 2005 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2469180
20 May 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2365735
14 November 2004 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3102347
24 August 2004 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2174895
19 August 2004 Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2174302
9 January 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1980279
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961045
18 September 2003 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1913657
6 November 2002 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 1702342
30 July 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1658451
12 April 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1605767
7 May 2001 Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1417272
4 January 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1603784
17 October 1998 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 94020
17 October 1998 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 228451
15 January 1998 Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 790445
15 January 1998 Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1114078
18 October 1997 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 47888
7 July 1997 Deficiency Check
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1364230
2 July 1997 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 166233
2 July 1997 Damage Survey
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1113335
24 January 1997 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 44901
30 December 1996 Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 158390
9 September 1994 Uninspected Towing Vessel
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1396173
8 September 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 62658
8 September 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 86373
6 February 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 669173
1 February 1993 Type not recorded
No type recorded · COTP SAULT ST. MARIE · USCG Great Lakes District (CGD-GL) · Activity 38346
1 February 1993 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 141248
20 January 1992 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 140863

Deficiency record · 17

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2024 Resolved
Electrical systems must be designed and maintained to provide for safe operation of the vessel and safety of persons onboard. The following electrical hazards were noted onboard: 1. There is an electrical extension cord running from the port side fidley thru the fwd engine room bulkhead and into the passage way. Remove the same. 2. The 120V outlet in the steering space has the hot and neutral reversed. Repair the same. 3. The six gang outlet extnsion used to charge the radio batteries is improper and has a metal screw driven through it. Remove the same and provide a proper outlet.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2024
Resolved 28 August 2024
Resolution: Witnessed satisfactory completion of all requirements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2024 Resolved
All seals and gaskets must be properly maintained to prevent leaks. Both port and starboard hydraulic steering units are leaking. Make repairs to the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2024
Resolved 28 August 2024
Resolution: Witnessed satisfactory repairs to the steering units.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 August 2024 Resolved
Each escape hatch used as a means of escape must be marked "Emergency Exit-Keep Clear". The hatch for the exit from the port side steering space is not marked on deck. Mark the same.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2024
Resolved 28 August 2024
Resolution: Witnessed satisfactory marking of the escape hatch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2024 Resolved
Electrical systems must minimize system failures and shock hazards. The cover for the circuit board as the bottom of the engine room ladder is missing. Replace the same.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2024
Resolved 28 August 2024
Resolution: Witnessed satisfactory replacement of the cover for the circuit boards.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 1 August 2024 Resolved
The manufacturers instructions for onboard maintenance of lifesaving appliancies must be on board vessel. Provide for immersion suits. Annual service is needed on 4 immersion suits aged 2007, 2009, 2009, 2014.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2024
Resolved 28 August 2024
Resolution: Witnessed copies of manufacturers instruction for maintenance of immersion suits onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 August 2024 Resolved
The fire detection system must be installed, tested, and maintained in accordance with the manufacturers design manual. Vessel must update their inspection sheets to include all PE letter components and manufacturers maintenance procedures. Provide OCMI with updated inspection list showing all applicable tests were conducted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2024
Resolved 13 August 2024
Resolution: verified proper testing procedures were created.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2023 Resolved
Electrical systems must be designed & maintained to provide for the safety of persons onboard. Provide blanks for the openings in breaker panel #4 on the main deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2023
Resolved 7 August 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 July 2023 Resolved
Each vessel must be provide with an industrial first aid kit. Remove and replace expired items in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2023
Resolved 7 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 July 2023 Resolved
A power driven vessel underway must display a stern light. The stern light is extinguished. Repair or replace the stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 August 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Minimum requirements)
Issued 18 July 2023 Resolved
Provide MIS report for CY 2022.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2023
Resolved 7 August 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 June 2022 Resolved
Vessel draft marks need to be contrasting color from the hull.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2022
Resolved 6 July 2022
Resolution: Draft marks were made contrasting color from hull.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 June 2022 Resolved
Emergency escape hatchs onboard are not functioning properly. Conduct maintenance and restore escape hatches to proper operation. 2 out of 3 in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2022
Resolved 6 July 2022
Resolution: Emergency escape hatches were made operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2022 Resolved
Steering pressure control valve has dripping/leaks every few seconds. Repair leaks to steering system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2022
Resolved 12 August 2022
Resolution: Leaks to port and starboard steering control blocks have been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2022 Resolved
Power panel on bridge must be marked with respective current and voltage rating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2022
Resolved 6 July 2022
Resolution: Bridge power panel was labeled with respective voltage/current.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 13 June 2006 Resolved
Oil transfer hose needs annual MAWP hydrostatic test as required under 33 CFR 155.80
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2006
Resolved 6 July 2006
Resolution: Inspected oil transfer hose with all the proper stenciling applied as per 33 CFR 155.80.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 13 June 2006 Resolved
Provide proof that portable Dry Chemical extinguisher is a USCG approved type B-V as required under 46 CFR 27.303.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 July 2006
Resolved 6 July 2006
Resolution: B-V has been inspected with sat results.
Construction/Loadline
Issued 2 July 1997 Resolved
APPROXIMATELY 3' OF OIL/WATER MIXTURE IN ENGINE ROOM BILGES.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997

Recorded names · 2

DONALD C. HANNAH (2001–2006), DONALD C (2011–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.