LAFARGE EAGLE

Built
1981
Last inspected
11 March 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 11 March 2024
…with no type recorded29
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 32 calendar years (1981–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-52713

Documentation record

Registered dimensions (L × B × D)323.4 ft × 64.0 ft × 22.0 ft
Registered tonnagegross 4,627 / net 2,548
ITC dimensions (L × B × D)323.4 ft × 64.0 ft × 22.0 ft
ITC tonnagegross 4,627 / net 2,548
BuilderTODD SHIPYARDS CORP · HOUSTON, TX, UNITED STATES · built 1981
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4627 - Convention (Subpart B), Gross Ton
2548 - Convention (Subpart B), Net Ton
8000 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 88 inspections, each with its date, unit and type; 73 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 16 other vessels inspected with it; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 16

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CALVIN Towing Vessel · MISLE 76892 · 19 April 2023 · activity 7673045MAUNA LOA Towing Vessel · MISLE 81729 · 26 February 2023 · activity 7662630LUTHER Towing Vessel · MISLE 135994 · 13 January 2022 · activity 7380237CALVIN Towing Vessel · MISLE 76892 · 29 July 2021 · activity 7273021OCEAN MONARCH Towing Vessel · MISLE 1190604 · 29 July 2021 · activity 7273021MAUNA LOA Towing Vessel · MISLE 81729 · 2 November 2020 · activity 7108600NORTH ARM PROWLER Towing Vessel · MISLE 999848 · 2 November 2020 · activity 7108600LUTHER Towing Vessel · MISLE 73187 · 26 January 2017 · activity 6079879CROSBY EAGLE Towing Vessel · MISLE 103082 · 20 January 2004 · activity 2094587CROSBY EAGLE Towing Vessel · MISLE 103082 · 17 January 2004 · activity 1988322NATHAN S Towing Vessel · MISLE 81517 · 12 April 2002 · activity 1605767MISS ANN Towing Vessel · MISLE 102396 · 2 July 1996 · activity 178404EVA Towing Vessel · MISLE 188421 · 2 July 1996 · activity 178404PACIFIC DAWN Towing Vessel · MISLE 129465 · 13 January 1996 · activity 516CAPT FRANK Freight Barge · MISLE 219334 · 13 January 1996 · activity 516ANGUS R. COOPER Towing Vessel · MISLE 85820 · 12 January 1996 · activity 101479PACIFIC DAWN Towing Vessel · MISLE 129465 · 12 January 1996 · activity 101479SARAH DANN Towing Vessel · MISLE 219180 · 30 March 1995 · activity 130419MARY ALICE Towing Vessel · MISLE 128905 · 17 September 1994 · activity 141242SARAH DANN Towing Vessel · MISLE 219180 · 30 April 1994 · activity 60489CROSBY PROGRESS Towing Vessel · MISLE 187075 · 18 November 1993 · activity 76596SARAH DANN Towing Vessel · MISLE 219180 · 2 October 1993 · activity 113455

Inspection history · 88

11 March 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7878049
19 April 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7673045
26 February 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7662630
13 January 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7380237
29 July 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7273021
2 November 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7108600
26 January 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6079879
12 February 2010 MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3681998
29 December 2008 Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3400973
1 July 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3247856
12 July 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2984838
27 June 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2693099
24 May 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2656181
2 March 2006 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2594812
28 June 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2406060
8 June 2005 MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2383809
2 June 2005 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2377191
11 August 2004 Administrative Inspection · MARPOL Annex I Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2162799
14 June 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2098156
21 May 2004 Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2073833
26 January 2004 Damage Survey · Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1993026
20 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2094587
17 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1988322
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978879
3 December 2003 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1957062
17 July 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1848900
1 July 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1905729
16 June 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1819100
19 February 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1746637
9 January 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1728021
2 January 2003 Damage Survey · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1725277
12 July 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1647593
27 June 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1637734
12 April 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1605767
6 March 2002 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1491811
26 July 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1069783
26 June 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393710
18 April 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1401458
26 February 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063858
12 February 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1058470
19 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 671168
12 January 2001 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452755
1 July 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421689
29 June 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1458547
13 February 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1436055
26 June 1997 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1375042
30 October 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 208185
30 October 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 765879
2 July 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 178404
6 May 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 872183
17 January 1996 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 873652
13 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 516
12 January 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 101479
30 March 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 130419
5 December 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 835541
4 November 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419329
17 September 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 141242
8 June 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1321738
30 April 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 60489
18 November 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 76596
2 October 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113455
18 June 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 844782
2 June 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1408967
16 February 1993 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 839701
14 May 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1258377
9 March 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1258375
22 January 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 671169
4 November 1991 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 939525
18 July 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962455
17 June 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1194340
10 September 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 918043
22 August 1990 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 904296
20 August 1990 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219305
18 May 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 931030
7 June 1989 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 891905
11 May 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1345662
25 April 1989 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1342197
15 May 1987 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1026040
29 September 1986 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1311552
23 May 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1295784
19 February 1986 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1299051
17 January 1986 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1303068
19 August 1985 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1293225
9 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988677
1 October 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 974323
13 September 1983 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 965128
10 August 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274462
6 August 1981 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 968815

Deficiency record · 73

Engineering › Fuel Oil Service System › Piping
Issued 27 June 2007 Resolved
Prove that leaks have been corrected on the prime mover fuel tank.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 2 August 2007
Resolution: Leaks are repaired.
Engineering › Compressed Air System (start air) › Valve
Issued 27 June 2007 Resolved
Prove annual test of the pressure vessel relief valves.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 2 August 2007
Resolution: Waltech report provided for annual servicing of the relief valves for air receivers.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 27 June 2007 Resolved
Install USCG approved bracket for portable fire extinguishers as required by 46 CFR 34.50-10.
Condition: Design Flaw
Due 27 July 2007
Resolved 2 August 2007
Resolution: Proper extinguisher brackets now in place.
Deck/Cargo › Cargo Stowage › General
Issued 24 May 2006 Resolved
Provide current certification of the testing and examination of winches, derricks, and their associated cargo gear for the two deck cranes prior to operating cranes but no later June 24, 2006 as required by 46 CFR 91.25-25 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 27 June 2006
Resolution: Received documentation of third party testing of both cranes.
Electrical › Electric Generation Source (service) › Generator
Issued 24 May 2006 Resolved
Repair and prove operation of overspeed device on ship's service generator as required by 46 CFR 111.12-1 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 27 June 2006
Resolution: Tested overspeed on ship''s service generator. Test was satisfactory.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 8 June 2005 Resolved
Provide copy of current valid Certificate of Fiscal Responsibility.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2005
Resolution: NPFC issued new COFR.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 June 2005 Resolved
Renew expired eye wash solution in the first aid kit.
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 28 June 2005
Resolution: Installed new eye wash solution and first aid kit.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 June 2005 Resolved
Replace missing hand rails in fore peak.
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 28 June 2005
Resolution: Installed new hand rail in fore peak.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 June 2005 Resolved
Label breaker amperage on circuit directory card for forward lighting distribution panel.
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 28 June 2005
Resolution: Installed new circuit directory card in panel.
Electrical › Electric Generation Source (service) › Generator
Issued 8 June 2005 Resolved
Remove jumper cables from batteries and hard wire electric starter for #2 cargo generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 28 June 2005
Resolution: Satisfactory installed new battery cable.
Electrical › Electric Generation Source (service) › Generator
Issued 8 June 2005 Resolved
Properly support electrical cables and wires on and in the vicinity of the #2 cargo generator and the service generator. Remove wire nuts and replace chaffed wire covering on the #2 cargo generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2005
Resolved 28 June 2005
Resolution: Wire nuts were removed and electrical cables were installed satisfactory.
Lifesaving
Issued 18 May 2004 Resolved
Forward port and starboard life buoys lines are sun damaged and must be replaced as per 46 CFR 199.70.(a)(3)(i). LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 14 June 2004
Resolution: Lines replaced.
Fire Fighting
Issued 18 May 2004 No resolution recorded
Properly label Emergency Shutdown for aft machinery space ventilation and equipment as per 46 CFR 111.103. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 17 June 2004 — due date passed with no resolution recorded
Resolution: Shutdowns properly labled and checked.
Electrical
Issued 18 May 2004 Resolved
Install guard on starboard deck light in way of crane as per 46 CFR 111.75-20(b). LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 14 June 2004
Resolution: Light guards installed.
Electrical
Issued 18 May 2004 Resolved
Secure loose wiring in machinery space as per 46 CFR 111.60-5. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 14 June 2004
Resolution: Loose wiring properly secured.
Electrical
Issued 18 May 2004 Resolved
Remove dead-end wire in way of starboard side running light as per 46 CFR 111.60-5. LEGACY COMPONENT DESC: Cable
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 14 June 2004
Resolution: Dead-end cable removed.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 May 2004 Resolved
Make permanent repairs to bowed frame (frame #12) starboard side no later than next dry dock. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 16 March 2006
Construction/Loadline › Hull
Issued 26 January 2004 Resolved
Prior to use of the starboard forward towing bit damaged by a dock allision, make permanent and proper repairs. Repairs to be made to the satisfaction of an attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 20 February 2004
Resolved 26 January 2004
Construction/Loadline › Hull
Issued 26 January 2004 Resolved
Provide Classification Society survey report addressing repairs once completed. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 20 February 2004
Resolved 26 January 2004
Operations/Management › Cargo Transfer/Lightering
Issued 17 June 2003 Resolved
Provide approved transfer procedures as required by 33 CFR 155.720. LEGACY COMPONENT DESC: Vessel Transfer Procedures on Hand
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 17 July 2003
Engineering › Fuel Oil Service System
Issued 17 June 2003 Resolved
Replace non-metallic flexible hose for fuel oil supply and return on auxiliary generator engine with hose lengths no longer than 30 inches as required by 46 CFR 56.60-25(b)(4). LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2003
Resolved 17 December 2003
Resolution: Hoses in question were replaced with approved hose as required by 46 CFR 56.60-25(b)(4).
Accommodation/Occupational Safety › Occupational Safety
Issued 17 June 2003 Resolved
Install guard over auxiliary generator engine flywheel as required by 46 CFR 58.01-20. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 17 July 2003
Electrical › Electric Generation Source (service)
Issued 17 June 2003 Resolved
Provide proper connections for wiring to gauges on auxiliary generator and remove dead-end wires as required by 46 CFR 111.60-17.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 July 2003
Resolved 17 July 2003
Construction/Loadline › Hull
Issued 8 January 2003 Resolved
You are hereby directed to drydock the vessel no later than November 30, 2003 to carry out permanent repairs to wasted bottom shell plating in No. 1 void in way of temporary repairs. All repairs shall be conducted to the satisfaction of the attending U.S. Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Due 30 November 2003
Resolved 17 December 2003
Resolution: Proper repairs (inserts) were made upon vessel drydocking. Repairs were tested and witnessed by CG and ABS reps.
Construction/Loadline › Structures
Issued 8 January 2003 Resolved
Make vessel available for Coast Guard inspection to conduct internal and external bottom shell plating examination in all voids, including all associated transverse and longitudinal frames, no later than November 30, 2003.
Due 30 November 2003
Resolved 17 December 2003
Resolution: Vessel was made available for inspection and proper repairs followed.
Construction/Loadline › Hull
Issued 8 January 2003 Resolved
You are hereby directed to monitor all voids and record results in the towing vessels official log. Any deterioration of condition or ingress of water shall be reported immediately to the local Officer in Charge, Marine Inspection. LEGACY COMPONENT DESC: Bottom Plating
Due 30 November 2003
Resolved 17 December 2003
Resolution: No ingress of water was reported.
Construction/Loadline › Hull
Issued 8 January 2003 Resolved
Make vessel available for Coast Guard internal examination of No. 1 void to determine the continued effectiveness of temporary repairs no later than February 28, 2003. LEGACY COMPONENT DESC: Bottom Plating
Due 28 February 2003
Resolved 19 February 2003
Engineering › Compressed Air System (start air)
Issued 27 June 2002 Resolved
Provide ASME approved safety relief valves for drybulk system and air compressor as required by 46 CFR Subchapter F. LEGACY COMPONENT DESC: Valve
Due 19 July 2002
Resolved 12 July 2002
Resolution: Air system was fitted with the proper ASME "coded" valves.
Deck/Cargo › Mooring/Anchoring
Issued 27 June 2002 Resolved
Replace wasted bits on port bow. Bits are inadequate for mooring due to excessive wastage. LEGACY COMPONENT DESC: Bits
Due 19 July 2002
Resolved 12 July 2002
Resolution: Bits on port bow were renewed.
Engineering › Generator (propulsion-electric)
Issued 27 June 2002 Resolved
Prove the proper operation of engine alarms on all four generators. Generator alarms were not functioning properly when tests were attempted on the 19th of June. LEGACY COMPONENT DESC: Engine Alarms
Due 19 July 2002
Resolved 12 July 2002
Resolution: Witnessed successful test of alarms and shutdowns on generators.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 27 June 2002 Resolved
Provide a proper bracket for loose fire extinguisher as required by 46 CFR 162.028-3(g). LEGACY COMPONENT DESC: Mounting Bracket
Due 19 July 2002
Resolved 12 July 2002
Resolution: Fire extinguisher was extra and removed from vessel.
Electrical › Electrical Distribution System (service)
Issued 27 June 2002 Resolved
Properly secure wiring in distribution panel in the forward machinery space, port side. LEGACY COMPONENT DESC: Wiring
Due 19 July 2002
Resolved 12 July 2002
Resolution: Wiring was properly secured in the distribution panel.
Electrical
Issued 26 June 2001 Resolved
INSTALL COVERS ON ALL OVERHEAD LIGHTS.
Condition: Unknown
Due 26 July 2001
Resolved 30 July 2001
Construction/Loadline › Hull
Issued 26 June 2001 Resolved
FABRICATE AND INSTALL STANCHION IN WAY OF PORT CRANE.
Condition: Unknown
Due 26 July 2001
Resolved 30 July 2001
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 June 2001 Resolved
REPAIR HANDRAIL STARBOARD SIDE FORECASTLE AS ORIGINAL.
Due 26 July 2001
Resolved 30 July 2001
Deck/Cargo
Issued 26 June 2001 Resolved
REPLACE HYDRAULIC HOSE ON STBD CRANE.
Condition: Unknown
Due 26 July 2001
Resolved 30 July 2001
Electrical
Issued 26 June 2001 Resolved
MOUNT J-BOX IN BOW RAKE STBD SIDE AFT OVERHEAD, IWO HATCH.
Condition: Unknown
Due 26 July 2001
Resolved 30 July 2001
Electrical
Issued 26 June 2001 Resolved
PROPERLY TERMINATE ELECTRICAL WIRES ON PORT AFT DECK LIGHT.
Condition: Unknown
Due 26 July 2001
Resolved 30 July 2001
Engineering
Issued 12 January 2001 Resolved
REPAIR LOOSE CABLES ON #2 CARGO GEN SET PANEL BOX.
Condition: Unknown
Due 12 February 2001
Resolved 1 May 2001
Engineering
Issued 12 January 2001 Resolved
PROVE PROPER OPERATION OF OVER SPEEDS & LOW LUBE OIL SHUT DOWN ON SERVICE GENERATOR SET.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Unknown
Issued 12 January 2001 Resolved
Company missed Internal Structural Exam date requirement. Date required was4 Nov 99 and ISE was conducted on 12 Jan 01.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Unknown
Issued 12 January 2001 Resolved
Vessel was due for Reinspection on 01 Jul 00. Reinspection was completed on12 Jan 01, over 6 months past required RIN.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Deck/Cargo
Issued 12 January 2001 Resolved
REPLACE FLEX HOSE ON COMPRESSOR PUMP IN FWD RAKE, STD SIDE.
Condition: Unknown
Due 12 February 2001
Resolved 23 February 2001
Electrical
Issued 12 January 2001 Resolved
REMOVE DEAD END WIRING IN BOTH MACHINERY SPACES.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Electrical
Issued 12 January 2001 Resolved
REPAIR/REPLACE DOOR TO ELECTRICAL PANEL BOX IN AFT MACHINERY SPACES (MIDSHIPS).
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Electrical
Issued 12 January 2001 Resolved
REPAIR ALL LIGHTING FIXTURES AND PROVIDE COVERS.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Electrical
Issued 12 January 2001 Resolved
PROVIDE CLAMPS FOR ALL DECK LIGHTING CABLES.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Accommodation/Occupational Safety
Issued 12 January 2001 Resolved
REPAIR OVERHEAD PANEL IN CONTROL ROOM.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Electrical
Issued 12 January 2001 Resolved
PLUG HOLES IN GENERATOR SET SWITCHBOARD IN CONTROL ROOM.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Electrical
Issued 12 January 2001 Resolved
PROVE PROPER OPERATION OF STBD AFT MACHINERY SPACE FAN SHUTDOWN (PORT SIDE FAN).
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Electrical
Issued 12 January 2001 Resolved
PROVIDE SPACES FOR FWD BATTERY BOX AND CLEAN CONTACTS. PROVIDE 2 SPACES FORAFT AFT BETTERY BOX.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Engineering
Issued 12 January 2001 Resolved
REWELD CRACK IN FUEL OIL CONTAINMENT STBD SIDE & DRAIN WATER.
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Electrical
Issued 1 July 1999 Resolved
VESSEL IS PROHIBITED FROM OPERATING THE NO.2 CARGO GENERATOR UNTIL ALARMS AND SHUTDOWNS HAVE BEEN DEMONSTRATED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 August 1999
Resolved 13 July 1999
Electrical
Issued 26 June 1997 Resolved
REPAIR AND TEST SHIP SERVICE GENERATOR PRIOR TO USE.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Construction/Loadline
Issued 26 June 1997 Resolved
MAKE VESSEL READY (GAS FREE) SO THAT A CG INSPECTOR MAY COMPLETE A CREDIT INTERNAL STRUCTURAL EXAMINATION. 46CFR91.40-3
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Construction/Loadline
Issued 26 June 1997 Resolved
RENEW DAMAGED SECTION OF BILGE KNUCKLE LOCATED ON STARBOARD SIDE OF VESSEL IN WAY OF NO.2 AND NO.3 WING VOID TO THE SATISFACTION OF THE ATTENDING _x001C_ U.S. COAST GUARD MARINE INSPECTOR PRIOR TO THE COMPLIANCE DATE._x001C_ SEE 46 CFR 91.30
Condition: Unknown
Due 11 September 1997
Resolved 11 September 1997
Documentation
Issued 26 June 1997 Resolved
PROVIDE FOR REVIEW AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN.
Condition: Unknown
Due 8 August 1997
Resolved 12 August 1997
Engineering
Issued 26 June 1997 Resolved
REMOVE DRAINING/BLEEDING PET COCKS FROM ALL DIESEL ENGINE FUEL STRAINERS_x001C_ OR PLUG ENDS TO PREVENT LEAKAGE. 46CFR56.50-60(F)
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Electrical
Issued 4 November 1994 Resolved
Provide proper guards and/or globes for deck lighting as necessary.
Condition: Unknown
Due 4 November 1994
Resolved 4 November 1994
Navigation
Issued 4 November 1994 Resolved
Make permanent repairs to all navigation lights._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 November 1994
Resolved 4 November 1994
Deck/Cargo
Issued 17 June 1991 Resolved
REPLACE ALL MISSING VALVE WHEELS ON CARGO LOADING DOMES._x001C_
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Deck/Cargo
Issued 17 June 1991 Resolved
REPLACE MISSING 8" BALL IN #4 CARGO HOLD VENT
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Electrical
Issued 17 June 1991 Resolved
INSTALL FLAME SHIELDS ON #2 CARGO GENERATOR, BARGE SERVICE GENERATOR, AND #4 CARGO GENERATOR._x001C_
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Deck/Cargo
Issued 17 June 1991 Resolved
REPLACE MISSING DOG ON #4 CARGO HOLD SOUNDING TUBE.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Unknown
Issued 17 June 1991 Resolved
REPLACE MISSING VALVE WHEEL ON FWD PORT AIR RECEIVER FILL LINE.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Accommodation/Occupational Safety
Issued 17 June 1991 Resolved
REPLACE WASTED HANDRAIL SECTIONS ON PORT SIDE.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Unknown
Issued 17 June 1991 Resolved
STENCIL ALL REMOTE FUEL OIL AND VENTILATION SHUTDOWNS
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Construction/Loadline
Issued 20 August 1990 Resolved
PROCEED EMPTY TO THEODORE, AL TO MAKE TEMPORARY REPAIRS TO FORWARD BULKHEAD#2 VOID (STBD) IN WAY OF BRACKET TO #1 SIDESHELL LONGITUDINAL. REPAIRS ARE TO BE TO THE SATISFACTION OF COGNIZANT [name withheld] 46CFR91.30-1
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Construction/Loadline
Issued 20 August 1990 Resolved
MAKE PERMENENT REPAIRS TO DAMAGE IN WAY OF #2 STBD VOID SIDESHELL AND DECK PLATE, AND ASSOCIATED INTERNAL MEMBERS FROM COLLISION ON 18 AUG 90. REPAIRSARE TO BE TO THE SATISFACTION OF THE COGNIZANT [name withheld] 46CFR91.30-1
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Documentation
Issued 18 May 1990 Resolved
PROVIDE OIL TRANSFER PROCEDURES WITH INDEX OR WITH ITEMS ARRANGED IN SAME ORDER AS 33CFR 155.750.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Deck/Cargo
Issued 11 May 1989 Resolved
CONDUCT INTERNAL EXAM AND PROVE PROPER OPERATION OF 4 AIR RECEIVERS AND THEIR RELIEF VALVES.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Construction/Loadline
Issued 11 May 1989 Resolved
MAKE FORWARD RAKE GAS FREE AND AVAILABLE FOR INSPECTION OF DAMAGE TO PORT SIDE SHELL.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Construction/Loadline
Issued 17 January 1986 Resolved
DAMAGE TO PORT SIDE FWD RAKE, FOUR FRAMES AND ASSOCIATED LONGS AND BRACKETSDAMAGED, ISSUED 835 TO MAKE REPAIRS AND NOT TO LEAVE PORT OF MOBILE WITHOUTPERMISSION OF OCMI.
Condition: Unknown
Due 17 January 1986
Resolved 17 January 1986

Recorded names · 2

IDEAL I (2002), HANNAH - 7701 (2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.