Inspection record

Last inspected 25 October 2025
…with no type recorded32
Operational controls None recorded without a removal date
Years with a record 19 calendar years (1993–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7427477
WDB7214
135994
Flag
UNITED STATES
Maury page id
psix-135994

Documentation record

Registered dimensions (L × B × D)104.6 ft × 32.0 ft × 14.1 ft
Registered tonnagegross 158 / net 107
ITC dimensions (L × B × D)104.6 ft × 32.0 ft × 14.1 ft
ITC tonnagegross 323 / net 96
BuilderDELMAR SYSTEMS INC · LAROSE, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 29 August 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it158 - Regulatory (Subpart C or D), Gross Ton
323 - Convention (Subpart B), Gross Ton
107 - Regulatory (Subpart C or D), Net Ton
96 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 53 inspections, each with its date, unit and type; 45 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 10 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 10

Inspection history · 53

25 October 2025 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8276870
25 September 2025 COI Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8241586
2 June 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8149808
2 June 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8149904
18 October 2024 Deficiency Check · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8022499
18 October 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8042297
5 September 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7997851
22 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7774363
10 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7765054
13 July 2023 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7768924
9 June 2023 Deficiency Check · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7710843
14 April 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7668815
13 April 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7668332
5 March 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7406234
13 January 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7380237
12 January 2022 Administrative Inspection · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7379712
22 July 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7264365
15 July 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7257591
4 October 2019 Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6820206
1 July 2019 Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6732136
31 August 2012 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4446855
5 June 2012 Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4335081
4 June 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4335098
18 February 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3960067
10 September 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3849178
20 January 2010 MTSA Verification · Industry Initiated Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3666735
14 November 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3098341
13 November 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3098331
25 March 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2897598
13 November 2006 MTSA Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2809414
7 January 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2640827
19 March 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2318054
22 October 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 106552
14 February 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 679276
29 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 679279
11 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 110563
11 December 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 140814
2 November 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 199746
3 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 46370
31 May 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 191209
31 May 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 766018
23 February 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 162916
14 June 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 765947
12 June 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 198644
22 February 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 90555
28 November 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 146116
3 November 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 138497
17 October 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 136289
8 June 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 672604
29 March 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 679280
26 March 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 679281
19 March 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 28336
13 March 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 212225

Deficiency record · 45

02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 9 October 2025 No resolution recorded
Vessel was found with an approximate 2’x2'x4” inset on the Port Bow. The swash plate bulkhead in the FWD Port fuel tank sustained damage and is showing majorr deflection. Vessel to crop and renew sideshell and swash plate bulkhead during the 31May2028 Drydock.
Action required: 705 - Other - as specified
Due 31 May 2028
Resolution: **Due by next DDX
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 September 2025 Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel missed 2nd annual exam. Conduct exam prior to conducting commercial operations. 46CFR 137.200
Action required: 705 - Other - as specified
Resolved 9 October 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 September 2025 Resolved
A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Vessel missed drydock and internal structural exams. Conduct exams prior to conducting commercial operations. 46 CFR 137.300
Action required: 705 - Other - as specified
Resolved 9 October 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 25 September 2025 Resolved
The installed GPS unit has been affected by rollover phenomenon and no longer displays the correct date, time, or position. Additionally, this is the unit that feeds the GPS position into the electronic charting program. Provide a GPS unit (including tying into the electronic charting program) that provides accurate/correct date, time, and position.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 4 November 2025
Resolution: See Narrative
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 25 September 2025 Resolved
Vessels fathometer was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 4 November 2025
Resolution: See Narrative
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 25 September 2025 Resolved
The vessel is not equipped with a Pilothouse Alerter System. Vessel required to install suitable system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2025
Resolved 4 November 2025
Resolution: See Narrative
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2025 Resolved
The small battery installation in the storage space below the pilothouse did not have any securing or enclosure devices. Vessel to secure batteries in an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2025
Resolved 4 November 2025
Resolution: See Narrative
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 October 2024 Resolved
The vessel and its equipment shall be suitable for the service for which the vessel is certificated, including the steering gear. Identify the source of problems which attributed to multiple losses of steering of both Number 1 and Number 2 systems on or around 18OCT2024 and demonstrate smooth operation to the satisfaction of the marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2024
Resolved 6 November 2024
Resolution: Verified proper operations and system integrity of both steering systems. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2024 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Verify to the satisfaction of the marine inspector the ability to pump the laz.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2024
Resolved 6 November 2024
Resolution: Verified satisfactory operation of bilge pumping in laz.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 October 2024 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency conditions exists or essential systems develops problems. Verify correct operation of the high water alarm in the laz to the satisfaction of the marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2024
Resolved 6 November 2024
Resolution: Verified satisfactory operation of high water alarm in laz.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 18 October 2024 Resolved
Each towing vessel must have a means to monitor and control the rudder angle at the operating station. Verity to the satisfaction of the marine inspector the correct operation of the rudder indicator.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2024
Resolved 6 November 2024
Resolution: Verified satisfactory operation of rudder indicator.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 October 2024 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel which may allow water to enter the vessel. These devices must be suitable for the expected route. The rotating wheel for the starboard side lazerette hatch is seized and does not move freely.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 October 2024
Resolved 7 November 2024
Resolution: Verified satisfactory operation of stbd side lazerette hatch closure device.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Multiple exposed wiring connections in lazarette, to include improper gasket material for electrical enclosures.
Action required: 60 - Rectify deficiencies prior to movement
Due 7 November 2024
Resolved 7 November 2024
Resolution: Verified satisfactory rectification for exposed wiring and proper gasket material for electrical enclosures.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 October 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Steady stream leak of hydraulic fluid on port side steering system observed during steering tests while at the dock.
Action required: 60 - Rectify deficiencies prior to movement
Due 7 November 2024
Resolved 7 November 2024
Resolution: Verified satisfactory rectification of approved hydraulic hoses & fittings to eliminate hydraulic leak.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 July 2023 Resolved
Vessel was unable to properly maneuver during underway drills. Troubleshoot, repair and schedule follow on inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2023
Resolution: Vessel throttles were installed backwards. Correctly installed throttles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 June 2023 Resolved
Vessel found to have a hydraulic leak IWO Stbd side steering ram. Repair steering ram to prevent leak.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2023
Resolution: Replaced steering ram.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2023 Resolved
Port side fire hose found to be wasted resulting in failure. Replace hose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2023
Resolution: Replaced hose
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 June 2023 Resolved
Fire outfit SCBA's found to be empty of air. Re-fill SCBA's and test in presence of CG inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2023
Resolution: Filled SCBA's.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2023 Resolved
Switchboard IWO engine room found to be missing non-conductive matting. Install non-conductive matting in front of switchboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 13 July 2023
Resolution: Installed rubber matting
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2023 Resolved
Water heater IWO engine room found to be not securely mounted. Secure water heater to prevent movement while underway.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 13 July 2023
Resolution: Mounted water heater.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2023 Resolved
Diesel tank IWO engine room found to be missing sight gauge protection in front of gauge. Install protective covering to prevent damage.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 13 July 2023
Resolution: Installed sight gauge protection.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 June 2023 Resolved
VHF radio's found to be installed without DSC function. Install radio's with DSC capability.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 22 August 2023
Resolution: Installed VHF DSC capable radio
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 June 2023 Resolved
Emergency escape door on second level found to be missing labeling on both sides. Install labeling to read "EMERGENCY EXIT, KEEP CLEAR" Clearly legible letters must be 2 inches high.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 22 August 2023
Resolution: Labeled doors used for emergency escape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 June 2023 Resolved
Port lower ring buoy and stbd upper ring buoy found to be wasted. Replace both ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 22 August 2023
Resolution: Installed new ring buoys.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 April 2023 Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel has failed to complete a annual inspection since 22JUL2021.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 13 July 2023
Resolution: Completed COI renewal
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 April 2023 Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Vessel has not conducted an ISE/DDX IAW COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 13 July 2023
Resolution: Completed Inspection to maintain Load Line to comply with 46 CFR 137.320
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 March 2022 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property and the environment. Vessel reported a hairline crack in the rub rail and potentially the hull/ fuel tank, causing diesel fuel to spill into the environment. Vessel to submit plans for permanent repairs, to the Coast Guard and ABS for approval. 46CFR140.205(a) * Def was extended till the vessel goes to DDX.
Action required: 705 - Other - as specified
Due 5 March 2022
Resolved 13 July 2023
Resolution: The following Main deck plating were renewed at this time as follows: PORTSIDE 1. A section 2500 x 1500 x 9.5 mm between Fr 4 to 8 1/2 IWO Chain locker and Ballast tank No 2 2. A section 1750 x 1500 x 9.5 mm between Fr 39 to 42 1/2 IWO Fuel oil tank No
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 January 2022 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation and be suitable for route and service. Vessel experienced a marine casualty where the towing wire was caught around the port side shaft and propeller. 46 CFR 143.205(c)
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 12 January 2022
Resolved 13 January 2022
Resolution: Received divers video footage detailing damage as minimal.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 22 July 2021 Resolved
A vessel that is 300 ITC or more is required to transmit Long Range Identification Tracking (LRIT) information (position reports). 33 CFR 169.205
Action required: 702 - Prior to embarking on international voyage
Resolved 29 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 22 July 2021 Resolved
Vessel must have an illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The compass or swing-meter must be readable from each operating station. 46 CFR 140.725 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2021 Resolved
Electrical components that pose an electrical hazard must be in an enclosure or junction box. Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.Remove all dead end wires as well. 46 CFR 143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 July 2021 Resolved
Install inflatable liferaft. 46 CFR 141.305 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 July 2021 Resolved
Fire Detection System: The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience, to comply with paragraphs (a)(1) through (6) of this section. 46 CFR 142.330 (a)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2021 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. 46CFR140.435
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2021 Resolved
Nonconductive mats or grating must be provided on the deck in front of each switchboard and, if it is accessible from the rear, on the deck behind the switchboard. 46CFR143.560(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 22 July 2021 Resolved
The master of a towing vessel must ensure that crewmembers are familiar with their fire-fighting duties, and, specifically how to don a firefighter's outfit and a self-contained breathing apparatus, if the vessel is so equipped. 46CFR142.245(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2021 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. 46CFR141.360(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 29 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 July 2021 Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel has failed to complete a annual inspection since 04 October 2019.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 22 July 2021
Resolution: MIs attended vessel to conduct satisfactory COI REN. COI issued
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 July 2021 Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. Vessel has sailed multiple times to Canada without an international endorsement on their Certificate of Inspection. Vessel to obtain international route endorsement on their COI prior to sailing international.
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Due 15 August 2021
Resolved 22 July 2021
Resolution: MIs attended vessel to conduct satisfactory COI REN. COI issued with appropriate endorsement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2019 Resolved
Vessel is missing the additional lifejackets at each normally manned watch station and additional immersion suits.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 3 July 2019
Resolution: Received photos showing PFD and Immersion Suits are in their applicable spaces (Bridge and Galley).
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 1 July 2019 Resolved
The liferaft weak link/painter was connected to the pelican hook. Each liferaft must have a painter system providing a connection between the vessel and the liferaft.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 3 July 2019
Resolution: Received photo showing the painter was connected to the loop below hydro-release (weak link) as per manufacturer instruction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019 Resolved
Port Aft lifering on the 01 deck had a wasted line connecting the light and lifering.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 July 2019
Resolved 1 July 2019
Resolution: Corrected on spot
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2019 Resolved
Stbd aft lifering on the 01 deck had a wasted line around the lifering itself.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 3 July 2019
Resolution: lifering replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 July 2019 Resolved
At least two fire fighting outfits and two self contained breathing apparatus need to be provided if the vessel is over 79 feet and is on a oceans route.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2019
Resolved 2 October 2019
Resolution: vessel now fitted with two FFE's.
Documentation › Logs/Records › Drug Test Records
Issued 31 August 2012 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 30 September 2012
Resolved 6 September 2012

Recorded names · 1

HOWARD OLSEN (2005–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.