Documentation record
Registered dimensions (L × B × D)113.0 ft × 27.0 ft × 15.3 ft
Registered tonnagegross 147 / net 100
ITC dimensions (L × B × D)113.0 ft × 27.0 ft × 15.3 ft
ITC tonnagegross 257 / net 77
BuilderSAN DIEGO MARINE CONSTRUCTION COMPANY · SAN DIEGO, CA, UNITED STATES · built 1963
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 1 April 2026 · expires 1 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it147 - Regulatory (Subpart C or D), Gross Ton
257 - Convention (Subpart B), Gross Ton
100 - Regulatory (Subpart C or D), Net Ton
77 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
14 February 2024
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7866022
12 February 2024
Drydock Exam · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7864467
4 October 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7803605
1 March 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7644411
26 February 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7662630
22 April 2022
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7436246
13 April 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7174626
2 November 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7108600
6 July 2020
Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6998905
23 May 2017
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6154391
14 May 2015
Administration
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5137152
15 September 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4984111
19 July 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4927874
11 October 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4166440
18 April 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3187021
5 February 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3154461
25 June 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2973440
10 February 2005
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2290445
17 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 70004
4 October 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 674586
23 August 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 124144
25 January 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 213836
19 December 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 62498
19 December 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 75367
19 December 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 171040
25 July 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 656177
26 March 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 496815
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 March 2023
Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel under normal conditions. The vessel's steering selector switch was missing a screw that connected to the stem of the drum switch. Replace the screw and conduct a successful steering test prior to vessel movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 2 March 2023
Resolved 2 March 2023
Resolution: The selector switch screw was replaced and the vessel conducted successful steering tests. The vessel was released by Transport Canada and can now operate.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 22 April 2022
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm). Vessel's fixed fire pump was only capable of delivering 31 psi of pressure. 46 CFR 142.325(a)(1)
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 22 April 2022
Resolved 5 May 2022
Resolution: Fixed fire pump is now operational and operating at 80psi.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 April 2022
Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of § 199.190 of this chapter. Liferaft is overdue for its annual servicing required by 46 CFR 199.190(g). 46 CFR 141.235(a)
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 22 April 2022
Resolved 5 May 2022
Resolution: O/O sent in servicing certs for immersion suits, inflatable L/R.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 April 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas to facilitate egress from each space and must be either: automatic, battery-operated with a duration of no less than 2 hours; or non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Vessel's emergency lighting was inoperable in the engine room and living areas. 46 CFR 143.410
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 5 May 2022
Resolution: Emergency lighting batteries are charged and operable.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 April 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Diesel and miscellaneous oils present throughout engine room on deck, open buckets, and engine room bilges. Oil-soaked absorbent pads also present throughout engine room. 46 CFR 142.220
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 5 May 2022
Resolution: E/R bilge and buckets of oil have been removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2022
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Vessel bilge piping system did not have the required check/foot valves. 46 CFR 143.275
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 5 May 2022
Resolution: Check valve installed on bilge suction piping.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2022
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Numerous electrical cables throughout engine room are not terminated properly. 46 CFR 143.400(a) & (e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 5 May 2022
Resolution: Electrical wires are now crimped and properly terminated
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2022
Resolved
Electrical components that pose an electrical hazard must be in an enclosure and electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Batteries for generators are not secured from shifting and are not in an enclosure or battery box. 46 CFR 143.400(e) & (g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 5 May 2022
Resolution: Batteries are now enclosed and secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 April 2022
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Port side handrail adjacent to bridge is rusted through. 46 CFR 144.800(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 5 May 2022
Resolution: Handrail on port side of bridge has been cropped and renewed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Fuel filters in the engine room do not have flame impingement bowls (i.e. heat deflector kit). 46 CFR 142.220
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 5 May 2022
Resolution: MDE fuel fliters fitted flame retardent bowls.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 22 April 2022
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. According to this approval series, there shall be four rocket projectiles, four primer-ejector cartridges, and four service lines. Vessel currently only has one of the four required and lacks the auxiliary line required by 46 CFR 141.385. 46 CFR 141.385
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 5 May 2022
Resolution: O/O bought and sent in invoice of 3 more line throwing devices, 4 are now on board.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 April 2022
Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management (BWM) plan that has been developed specifically for the vessel as per 33 CFR 151.2050(g). Vessel does not have the aforementioned ballast water management plan as per 33 CFR 151.2050(g). 33 CFR 151.2050(g)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2022
Resolved 25 May 2022
Resolution: Received notice from company that ballast water management plan was being prepared.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 22 April 2022
Resolved
Each towing vessel must perform the applicable tests in 46 CFR Table 143.245(b). The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel has not logged any tests required by this section since 2019. 46 CFR 143.245
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2022
Resolved 25 May 2022
Resolution: Received notice from the company that machinery related- tests were being conducted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2020
Resolved
A remote fuel shutoff valve must be fitted on fuel lines that supply fuel directly to propulsion engines and generator engines. Install remote operated valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2020
Resolved 8 January 2021
Resolution: Witnessed operation of fuel valves, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 August 2020
Resolved
The fire hose hydrant was leaking. Repair leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2020
Resolved 2 November 2020
Resolution: Hydrant replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 August 2020
Resolved
The fire pump must be able to be energized remotely from outside the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2020
Resolved 2 November 2020
Resolution: Remote activation installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2020
Resolved
Various wires are exposed and not enclosed in proper fixtures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2020
Resolved 2 November 2020
Resolution: Wires throughout replaced.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 10 August 2020
Resolved
General alarm sign must be posted in the engine room that reads IAW the regulation cited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2020
Resolved 2 November 2020
Resolution: Genarl alarm installed.