Records from 2016 to 2025. Most recent: inspection, 11 August 2025.
Inspection history · 67
11 August 2025
Administrative Inspection · COC-CVE Annual
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8207543
2 October 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8014154
26 September 2024
COC-CVE Quarterly · PSC B · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8009646
21 June 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7956526
9 May 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7927211
8 May 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7926563
24 April 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7917564
10 April 2024
PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7890594
4 April 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7900016
9 March 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7889986
22 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7878079
7 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7870651
23 January 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7874074
1 November 2023
PSC B · COC-CVE Quarterly
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7818717
8 July 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7805669
7 July 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7811955
26 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7808922
7 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7762520
26 May 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7697419
26 May 2023
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7983073
18 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7744859
8 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7733059
21 April 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7673167
20 April 2023
PSC B · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7671945
13 February 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7636115
4 January 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616381
21 November 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7598157
15 November 2022
PSC B · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7591737
12 October 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576262
23 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7541988
8 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7528563
29 July 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7519770
25 July 2022
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7538463
23 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7485447
13 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476499
13 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476508
13 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476518
13 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476525
13 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476530
13 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476539
13 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476544
5 May 2022
COC-CVE Annual · Administrative Inspection · PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7438586
6 March 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7549218
28 December 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7373279
5 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935494
31 March 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933612
7 October 2019
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6829922
7 March 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6638519
17 November 2018
ISPS III Exam · COC-CVE Annual · Deficiency Check · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581873
3 April 2018
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6384769
16 March 2018
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6371862
12 January 2018
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6337031
12 January 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6341949
13 October 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6286910
18 September 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6271059
17 September 2017
COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6267511
26 October 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6036304
20 October 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6027100
10 October 2016
COC-CVE Annual · Administrative Inspection · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6020203
5 September 2016
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6002671
7 August 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5965157
12 July 2016
MARPOL Annex IV Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5938406
18 April 2016
Ballast Water Examination · COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5856585
17 April 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5860897
30 March 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5843976
20 March 2016
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5836886
20 January 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5825696
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 September 2024
Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed waste receptacles constructed of combustible materials in crew mess room, deck 5, aft.
74 SOLAS (20 cons.) II-2/4.4.2 Action: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 10 October 2024
Resolution: Waste receptacles replaced with metal ones. See documents tab for class report.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 September 2024
Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location of operation of any fire-fighting systems and appliances that they may be called upon to use. Two (2) mess cooks and one (1) chief chef on deck 5 and 6 galleys were not familiar with the location nor operation of the installed fire suppression system for deep fat fryer. 74 SOLAS (20 Cons) II-2/ 15.2.2.1 Action: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 10 October 2024
Resolution: Galley staff retrained on use of fire suppression system. See documents tab for class report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 September 2024
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ebsured. PSCO observed water leak from an HVAC unit at the theater on deck 6 near lighting fixtures creating electrical hazard. 74 SOLAS (04 Cons) II-1/40.1.3. Action: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 18 October 2024
Resolution: HVAC leak repaired. See documents tab for class report.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 26 September 2024
Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of water into which it is to be launched appliance, and the area of water into which it is to be launched shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO observed emergency lighting at Lifeboat 2, 18, and forward MES was not operational. 74 SOLAS (20 cons) III/16.7. Action: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 10 October 2024
Resolution: Emergency lighting was replaced. See documents tab for class report.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 September 2024
Resolved
After any survey of the ship under regulations 7,8,9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed soft patch repair on potable water piping. 74 SOLAS (20 Cons) I/11(b) Action 50ac.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 18 October 2024
Resolution: Potable water piping was permanently repaired. See documents tab for class report.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2024
Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the Organization, indicating the devices stowed in location for that purpose. If more than one device is stowed in that location, the number of the devices must be indicated. Lifesaving equipment on bridge did not indicate number of devices stowed. 74 SOLAS (20 Cons) III/ 20.10 Actin: 50 ac.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2024
Resolved 18 October 2024
Resolution: Lifesaving equipment was properly labeled. See documents tab for class report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 September 2024
Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors were situated. Fire screen Door 15.2.01 and scullery door 5717 installed incorrectly preventing from closing. 74 SOLAS (20 Cons) II-2/ 9.4.1.1.2. Action 10c.
Action required: 10 - Deficiency Rectified
Resolved 26 September 2024
Resolution: Vessel crew installed door properly providing satisfactory closure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 April 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10s from the beginning of their movement. Fire screen door 9.07.05 sliding door to stairway not operating properly. Did not close or sequence properly.
74 SOLAS 20 II-2/9.4.1.1.5.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2024
Resolution: Vessel repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 April 2024
Resolved
For determining the appropriate fire integrity standards to be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in categories (1) to (14) below. Technical spaces/fire stations located in multiple category three corridors had combustibles stored inside the space/station (fire stations
10.VI.02 and 10.IV.04 and technical space near cabin
C534 and C327).
74 SOLAS 20 II-2/9.2.2.3.2.2
Action required: 10 - Deficiency Rectified
Resolved 10 April 2024
Resolution: Cleared out combustable items on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 April 2024
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Lifeboat #14 on the port side did not
engage when initially tested.
74 SOLAS 20 III/20.2
Action required: 10 - Deficiency Rectified
Resolved 10 April 2024
Resolution: Vessel got engine to engage prior to CG departure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 November 2023
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light background. PSCO observed the deck line was painted the same color as the hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2023
Resolved 14 November 2023
Resolution: Received LR Report.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 November 2023
Resolved
Muster and embarkation stations shall be adequately illuminated. PSCO observed 03 lights (bow, fwd of lifeboat 10, and aft of rescue boat) not working when the emergency lighting was turned on.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 14 November 2023
Resolution: Received LR Report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2023
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing and other damage. Lifeboat lighting junction in the vicinity of the painter line number 8 for lifeboat 4 is wasted and not supported.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2023
Resolved 14 November 2023
Resolution: Received LR Report.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 27 May 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported a temporary loss of propulsion on Port side caused by an internal communication error. Vessel representative communicated a software analysis needs to be completed by a shore side technical team to determine full extent of issue. 74 SOLAS 20 I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 June 2023
Resolved 3 June 2023
Resolution: Received Class Report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 20 April 2023
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The rations shall be packed in
permanently sealed metal container or vacuum packed. 05 rations were
no longer vacuum packed.
74 SOLAS 20 III/34 LSA Code 4.1.5.1.18
Action required: 10 - Deficiency Rectified
Resolved 20 April 2023
Resolution: 05 new rations provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 20 April 2023
Resolved
All Life-saving appliances shall be in working order and ready for immediate use. Tender 20's hand break was not operating properly, required crew members to activate brake
74 SOLAS 20 111/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2023
Resolution: Hand break serviced and retested sat. Changed to a 10C.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2023
Resolved
Fire-fighting systems and appliances shall be kept in good workingorder and readily available for immediate use. Fire hose had tear near coupling.
74 SOLAS 04 11-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 20 April 2023
Resolution: New hose provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 October 2019
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces. The secondary means of escape utilizing F.S.D. 14.6.03 was locked from the inside and unable to be opened by the crew. 74SOLAS(14 Cons.)II-2/13.3.2.2
Action required: 10 - Deficiency Rectified
Resolved 8 October 2019
Resolution: The crew adjusted the lock on the door and used WD-40 to free up the lock.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 October 2019
Resolved
"A" class divisions formed by bulkheads shall be so constructed as to be capable of preventing the passage of smoke and flame. Multiple class "A" door frames throughout vessel have unauthorized modifications of added plate around latch area. 74SOLAS(14 Cons.) II-2/3.2.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 24 October 2019
Resolution: Class report submitted.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 October 2019
Resolved
Fire doors in main vertical zone bulkheads, galley, boundaries and stairway enclosures... shall be self-closing. F.S.D.'s 5.5.03, 2.4.07, 4.3.25, 4.3.19, and 6.3.09 would not fully close. 74SOLAS(14 Cons.) II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Resolved 8 October 2019
Resolution: The crew adjusted all F.S.D.'s so that they were capable of fully closing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2018
Resolved
9900 - Other Safety - Each passenger stateroom and crew cabin shall be equipped with entry doors that include peep holes or other means of visual identifications. Cabin numbers: 8639, 9739, 10343, 11661, 12647, 14635 do not have peep holes. - 46 USC 3507(a)(1)(B)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2018
Resolved 28 November 2018
Resolution: Peep holes provided for listed doors, as confirmed by class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 November 2018
Resolved
0750 - Fire prevention - The construction of doors and door frams shall provided resistance to fire equivilant to that of the bulkheads in which the doors are situated. The following doors did not properly close: 12647, 8635, 7.3.08, 15.7.04, 15.4.08, 16.2.11, 16.2.05. - 74 SOLAS (2014) II-2/9.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2018
Resolved 28 November 2018
Resolution: Listed fire doors were adjusted and confirmed by class as operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 November 2018
Resolved
9900 - Safety (other) - Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. The quick release bar on door 6.7.14 would not properly open the door. - 74 SOLAS (2014) II-2/13.3.2.6.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2018
Resolved 28 November 2018
Resolution: Quick release for listed door tested and found sat, as confirmed by class.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 November 2018
Resolved
0720 - Fire fighting equipment - Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire hose and extinguisher access door number 16.2.06 would not open. - 74 SOLAS (2014) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 November 2018
Resolved 17 November 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 November 2018
Resolved
0730 - Appliances - Manually operated call points shall be placed effectively to ensure a readily accessible means of notification. Manual call point number SECT52/ADDRESS3 does not work. - 74 SOLAS (2014) II-2/7.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 November 2018
Resolved 17 November 2018
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 16 March 2018
Resolved
0630- 74 SOLAS (14) III/20.3.1- Port side aft MES station is provided with a status indication device to show the status of side shell doors below the MES. Lights on devices are unable to be identified.
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 16 March 2018
Resolution: Panel lights switched out and relabled. Indication device now in working condition.
Personnel › Training › Familiarization Training
Issued 16 March 2018
Resolved
0999- 74 SOLAS (04) II-2/15.2.2.1- Various Personnel in multiple galleys were unable to explain the activation of the installed firefighting system over the deep fat fryers.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 March 2018
Resolved 24 March 2018
Resolution: Flag went onboard the vessel while inport on the 24MAR18 in Miami to rectify deficiencies. Report uploaded in documents.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 March 2018
Resolved
2535- 74 SOLAS (14) IX/3.1 ISM CODE A/10.2.4- The vessel provided checklist completed on 14MAR18 that showed/indicated satisfactory inspections on the MES control panel indicator. PSCO observed port side aft MES control unit corroded and not operating as designed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 March 2018
Resolved 24 March 2018
Resolution: Flag went onboard the vessel while inport on the 24MAR18 in Miami to rectify deficiencies. Report uploaded in documents.
Fire Fighting › Combustible Materials › Draught Stops
Issued 18 April 2016
Resolved
Spaces are classified accordint to their fire risk as shown in categories (1)-(14). Category 10 Auxiliary machinery spaces which do not contain machinery having pressure lubrication, where storage of combustibles is prohibited. Nearly all category 10 spaces down in the engine room have the storage of PVC and rubber materials.
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 22 April 2016
Resolution: Recieved class report attesting to rubber material being removed and PVC being a new type of non combustible PVC.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 18 April 2016
Resolved
Machinery and assorted piping systems shall be of a design and construction asdequate for service intended. Remote and emergency fuel shut off on Main Engines 2-6 had difficulty closing
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 22 April 2016
Resolution: Recieved class report attesting to the proper operation of the remote and emergency fuel shut offs.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 20 March 2016
Resolved
1410 The condition of the ship and its equipment shall be maintained to conform with the provisions to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel while transiting to the San Francisco COTP zone reported issues with the Programmable Logic Controller (PLC) on the propulsion... Deficiency continued in narrative.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2016
Resolved 21 March 2016
Resolution: Recieved and reviewed classification survey from LLoyds Register #SFO1600013 attesting to proper repairs and sastisfactory operation of the propulsion system.