Records from 2005 to 2026. Most recent: inspection, 13 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)282.0 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 2,792 / net 2,792
ITC dimensions (L × B × D)282.0 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 3,195 / net 1,568
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2006
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 12 August 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2792 - Regulatory (Subpart C or D), Gross Ton
3195 - Convention (Subpart B), Gross Ton
2792 - Regulatory (Subpart C or D), Net Ton
1568 - Convention (Subpart B), Net Ton
6212 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 44
13 April 2026
COI Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8346906
12 March 2026
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8324391
25 June 2025
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8167276
20 March 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8096889
4 April 2024
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7889723
4 April 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7954862
8 March 2024
Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870742
5 October 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7803798
29 June 2023
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7727175
12 July 2022
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7504919
20 April 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179201
29 March 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179163
15 March 2021
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156597
27 May 2020
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6953156
26 July 2019
Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6763380
14 March 2019
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6642319
6 June 2018
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6433833
27 June 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6189000
24 April 2017
MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6131573
17 March 2016
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5835823
19 February 2016
COI Inspection · Drydock Exam · MTSA Verification · Internal Structural Exam · Cargo Tank Internal · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5817672
18 September 2015
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5721952
3 October 2014
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4998318
3 September 2014
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4972080
14 March 2014
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4816327
6 February 2014
Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4794712
25 July 2013
MTSA Verification · Periodic Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4663963
28 August 2012
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4424150
28 July 2011
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4098459
12 July 2011
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4063065
30 November 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3901894
30 November 2010
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3901989
27 October 2010
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3878879
12 October 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3868215
8 February 2010
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3676810
24 September 2008
Administrative Inspection · Annual Inspection · MTSA Verification · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3331445
7 June 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3230689
10 August 2007
MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3023138
31 May 2007
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2951033
22 December 2006
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2844817
19 December 2006
Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2843198
15 December 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2841166
6 July 2006
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2703338
13 May 2005
Cargo Tank Internal · MTSA Verification · Hull Examination · MARPOL Annex I Examination · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2759483
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 June 2023
Resolved
unable to verify Pressure Relief valve set point to the air receiver.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2023
Resolved 5 October 2023
Resolution: relief valve replaced
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 19 February 2016
Resolved
Cargo tank overfill/high-level devices were unable to be tested during the inspection as they were seized in place due to solidified asphalt residues. Demonstrate proper operation of all cargo tank overfill/high-level devices in the presence of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 17 March 2016
Resolution: Tested all alarms sat.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 18 September 2015
Resolved
Replace 3 faded rising stick gauges
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2015
Resolved 23 September 2015
Resolution: Replaced 3 faded rising stick gauges
Lifesaving › Lifebuoys › Quantity
Issued 3 September 2014
Resolved
Vessel does not have a sufficient number of life buoys. Install 6 additional ring buoys on vessel for a total of 8 on board. Ensure one half of all ring buoys are fitted with self-igniting light and there is at least one life buoy on each side with a lifeline.
Action required: 705 - Other - as specified
Due 9 November 2014
Resolved 6 November 2014
Resolution: Vessel rep provided evidenceof required lifebuoys with required amount of lights and throw lines
Construction/Loadline › Hull › Weld
Issued 6 February 2014
Resolved
Perform air test on #5P cargo tank. Clean tank in area of possible leak (in double hull: aft bay, 2nd bay from port IWO tank bottom, aft bulkhead, and longitudinal swash bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2014
Resolution: Received, reviewed, and accepted class report from ABS stating that affected area was rewelded and a satisfactory air test was performed. Class report attached to actvity #4794712.
Construction/Loadline › Hull › Longitudinal Frame
Issued 6 February 2014
Resolved
#5P void: V/W 3rd SSL from bilge turn IWO aft bulkhead.
Due 24 March 2014
Resolved 14 March 2014
Resolution: Verified proper repairs.
Construction/Loadline › Penetrations › Gasket
Issued 6 February 2014
Resolved
Replace all gaskets on all void hatch covers and make ready for CG inspection.
Due 24 March 2014
Resolved 14 March 2014
Resolution: Examined replacement of gaskets; all sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 25 July 2013
Resolved
Update 2P distirbution panel Legend located in accom space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 25 July 2013
Resolution: Legend installed/updated.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 25 July 2013
Resolved
Hydro Air reciver located in the engine room in the presence of USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 26 July 2013
Resolution: Witnessed SAT Hydro of air reciver.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 25 July 2013
Resolved
Post required donning placard in crew space for all type 1 PFD's located onboard barge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 25 July 2013
Resolution: Placard Posted
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 July 2013
Resolved
Install/Update first aid kit in accor with cite: 46CFR32.35 / 46CFR113.25
Condition: Improper/Lack of Maintenance
Due 25 July 2013
Resolved 25 July 2013
Resolution: Vessel purchaed new first aid kit in accord with Ref cite
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 July 2013
Resolved
Replace testing kit. Current kit is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2013
Resolved 25 July 2013
Resolution: New kit purchased. Verified exp date. ALL SAT
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 25 July 2013
Resolved
Repair gauging device/high level alarm located at/on the # 3P Cargo tank.
Condition: Improper/Lack of Maintenance
Due 1 August 2013
Resolved 25 July 2013
Resolution: PMS Performed. Verified gauge and HL alarm both operational
Lifesaving › Inflatable Liferafts › Container Construction
Issued 25 July 2013
Resolved
Reservice/Replace liferaft installation. Liferaft not servicable due to damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2013
Resolved 5 August 2013
Resolution: Reservicing certificated recived and placed in vessels documents
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 28 August 2012
Resolved
PROVE TESTING OF CARGO PUMP DISCHARGE GAUGES AND RELIEF VALVES.
Due 5 September 2012
Resolved 29 August 2012
Navigation › Collision/Grounding Avoidance › Lead Line
Issued 28 August 2012
Resolved
PROVIDE LINE THROWING APPLIANCE ON BOARD VESSEL.
Due 5 September 2012
Resolved 29 August 2012
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 28 August 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 5 September 2012
Resolved 29 August 2012
Engineering › Fuel Oil Service System › Filter
Issued 28 August 2012
Resolved
PROVIDE DIESEL ENGINES WITH FUEL FILTER BOWLS IAW
Due 28 September 2012
Resolved 28 August 2012
Electrical › Electric Generation Source (service) › Generator
Issued 28 July 2011
Resolved
Generator #2 unable to test for overspeed trip due to technicians computer not being able to synchronize with generator's control unit. Provide test of overspeed trip on Generator #2 IAW 46 CFR 111.12-1(b).
Due 29 August 2011
Resolved 19 August 2011
Resolution: Vessel satisfactorily tested the overspeed trip on Generator #2.
Deck/Cargo › Cargo Heating › General
Issued 12 July 2011
Resolved
Thermal fluid heater did not have nameplate with proof of temperature and pressure derating. Provide nameplate on thermal fluid heater to proof of operating temperature and pressure IAW 46 CFR 61.30-1 no later than 12 August 2011.
Due 19 August 2011
Resolved 19 August 2011
Resolution: Vessel provided nameplate for thermal fluid heater with proof of operating temperature and pressure.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 12 July 2011
Resolved
Liferaft located on port deckhouse is unable to be launched from starboard side. Provide liferaft on starboard side or move liferaft so that it can be launched from port and starboard side IAW 46 CFR 199.261(b)(2) no later than 12 August 2011.
Due 12 August 2011
Resolved 28 July 2011
Resolution: Vessel moved liferaft to the main deck and mounted on stbd deckhouse. The liferaft is now capable of being launched from the port and stbd side.
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2011
Resolved
Unable to test generators for overspeed shutdown. Perform overspeed shutdown in the attendance of a CG marine inspector IAW 46 CFR 111.12-1(b) no later than 12 August 2011.
Due 12 August 2011
Resolved 28 July 2011
Resolution: Vessel performed overspeed test on generator #1 and #3 but were unable to test on generator #2. Issued additional CG-835 for generator #2.
Communications › Radio Communications › EPIRB
Issued 12 October 2010
Resolved
HRU expired
Action required: 705 - Other - as specified
Resolved 27 October 2010
Resolution: A new hydrostatic release unit was installed on the EPIRB to expire 10/2012.
Construction/Loadline › Hull › Bottom Plating
Issued 1 June 2007
Resolved
Vsl must provide dive survey for bottom plating after grounding in soft mud in Hudson River.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2007
Resolution: Survey provided.
Construction/Loadline › Hull › Bottom Plating
Issued 22 December 2006
Resolved
#1 starboard void tank breached for about 32'. Prior to commercial operations, proceed to dry dock for permanent repairs. insure barge is gas freed and clean to the satisfaction of a CG MI or class.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 February 2007
Resolution: Vessel completed permanent repairs to vessel hull.