MAURY USCG vessel records Sign in
← All vessels

STENA PERFORMANCE

STENA PERFORMANCE is a 2006 tank ship. The Coast Guard has recorded 32 inspections since 2006, most recently in September 2022, along with 2 deficiencies and 6 operational controls.

Records from 2006 to 2022. Most recent: inspection, 10 September 2022.

Built
2006
Last inspected
10 September 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9299159 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
836659
Flag
BERMUDA
—
Maury page id
psix-836659

Inspections, by type

…with no type recorded13
Years with a record 12 calendar years (2006–2022)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it77814 - Displacement, Metric Ton
65065 - Dead Weight, Metric Ton
36210 - Convention (Subpart B), Gross Ton
19687 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STASINOS BOYS Towing Vessel · MISLE 135074 · 3 May 2017 · activity 6138208PATRICE MCALLISTER Towing Vessel · MISLE 496619 · 3 May 2017 · activity 6138208SEA SPIKE Tank Ship · MISLE 1217618 · 3 May 2017 · activity 6138208

Inspection history · 32

10 September 2022 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7550692
24 August 2022 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7541726
19 June 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7481378
13 December 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7367421
2 December 2021 PSC B · COC-CHEM & TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7359245
21 March 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7160052
1 December 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7101621
24 April 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6943732
27 December 2019 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6873557
13 October 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6833692
26 October 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6568862
19 May 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6150244
3 May 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6138208
29 April 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6134984
26 April 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6132866
22 September 2011 COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4150260
10 January 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3923886
17 September 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3851666
20 April 2009 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3456486
17 June 2008 MARPOL Annex I Examination · COC-TVE Renew · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3239025
29 October 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3089218
11 July 2007 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2991425
2 March 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2880638
28 February 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2879629
9 January 2007 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2853070
9 January 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2853633
9 August 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2741878
4 August 2006 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2735845
28 July 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2727546
26 July 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2725463
19 July 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2718340
12 July 2006 ISPS II Exam · COC-TVE Renew · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2710515

Deficiency record · 2

Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 22 September 2011 Resolved
CARGO SHIPS OF 1000 GT AND UPWARDS SHALL BE PROVIDED WITH AT LEAST 02 INDEPENDENTLY DRIVEN FIRE PUMPS. VESSEL STBD SIDE FIREPUMP IS INNOPERABLE.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 September 2011
Resolved 26 September 2011
Resolution: STBD FIREPUMP WAS TEMPORARILY REPLACED TO THE SATISFACTION OF CLASSIFICATION SOCIETY.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 July 2006 Resolved
Prove proper operation of the oily water separator to the satisfaction of the attending DNV class surveyor. Until such time, all Oily bilge water is to be retained aboard until the completion of a satisfactory test of the monitoring device and alarm. Proof of proper operation of the system to be provided to local OCMI and Coast Guard office in St. Croix.
Action required: 705 - Other - as specified
Resolved 4 August 2006
Resolution: As per class report; the combined "smart-cell and smart-bilge" system was changed out in its entirety. Normal system operation was demonstrated by crew and witnessed by DNV with all function parameters, alarms, etc. found in good order.

Ownership record