Inspection history · 40
15 April 2026
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8323901
16 May 2025
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8137711
9 October 2024
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8016539
5 March 2024
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7874261
30 January 2024
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7858117
1 March 2023
Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7643674
11 October 2022
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7574867
16 February 2022
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7397083
17 February 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7141592
19 February 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6911343
15 November 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6856210
14 February 2019
COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6624591
30 July 2018
Damage Survey · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6498174
4 April 2018
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6384783
26 October 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6299795
17 October 2017
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6289111
21 August 2017
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6247476
1 March 2017
Administrative Inspection · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6096795
3 March 2016
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5826016
18 February 2015
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5070586
4 December 2014
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5033944
19 February 2014
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4797109
20 December 2013
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4773307
30 November 2012
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4495042
12 November 2012
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4491227
19 October 2012
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4467517
5 April 2012
DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 4279662
16 February 2012
Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4245425
18 February 2010
Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3681904
24 September 2009
Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3602171
20 February 2009
COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3420570
21 February 2008
Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3128506
31 January 2007
COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2864541
2 February 2006
COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2573610
1 February 2005
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2277839
6 January 2005
Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2269792
30 March 2004
Internal Structural Exam · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2023246
20 March 2003
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1756923
14 January 2003
Hull Examination · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1728012
22 February 2002
Initial Certification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1488201
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 February 2020
Resolved
Fire extinguisher appliances shall be serviced annually. The semi-portable extinguisher was last serviced October 2018.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2020
Resolution: A replacement extinguisher has been placed onboard and the hose changed out.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 February 2019
Resolved
The brackets for the portable fire extinguishers are deteriorated; repair or replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 19 March 2019
Resolution: Brackets have been replaced with CG approved SS brackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 February 2019
Resolved
The wheeled cart for the B-V semi-portable fire extinguisher is deteriorated; repair or replace as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 19 March 2019
Resolution: A new aluminum cart was fabricated for the bottle and hose assembly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 February 2019
Resolved
The lifeline on the port aft lifebuoy is deteriorated; replace the lifeline.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 19 March 2019
Resolution: Lifeline has been renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 February 2019
Resolved
The stbd aft lifebuoy is not properly mounted; provide a bracket and mount as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 19 March 2019
Resolution: Both brackets were replaced with stainless steel brackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 February 2019
Resolved
The two scuttles to the forward rake do not have retaining chanis attached; attach the covers to chains.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2019
Resolved 19 March 2019
Resolution: Retaining chains properly installed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 March 2016
Resolved
The current COD was not onboard and POC was unable to provide proof of current COD.
Due 3 April 2016
Resolved 12 April 2016
Resolution: Documentation received by owner and placed on vessel.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 February 2015
Resolved
The batteries in the lights are one year old, renew the batteries in accordance with the manufactures instructions.
Due 25 February 2015
Resolved 18 February 2015
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 18 February 2015
Resolved
The hose on the B-V semi-portable fire extinguisher is not long enough to reach the bow of the barge and therefore must be replaced with one that is long enough.
Due 19 February 2015
Resolved 18 February 2015
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 April 2012
Resolved
Company did not have current Substance Abuse Professional name or contact.
Action required: 705 - Other - as specified
Resolved 18 October 2012
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 April 2012
Resolved
Company is enrolled with Professional Nursing Service. Need to have copy of contract with updated employee list.
Action required: 705 - Other - as specified
Resolved 18 October 2012
Stability › Watertight Integrity › General
Issued 16 February 2012
Resolved
Provide a dogging bar for the stbd aft manhole cover.
Due 17 February 2012
Resolved 16 February 2012
Stability › Watertight Integrity › General
Issued 16 February 2012
Resolved
Ensure all dogging bars on all the manhole covers are properly pinned in place.
Due 17 February 2012
Resolved 16 February 2012
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 20 February 2009
Resolved
Re-paint the draft marks in contrasting color.
Due 27 February 2009
Resolved 27 February 2009
Lifesaving › Lifebuoys › Quantity
Issued 20 February 2009
Resolved
Provide the vessel with two additional life rings.
Due 27 February 2009
Resolved 27 February 2009
Documentation › Certificates/Documents › Stability Letter
Issued 20 February 2009
Resolved
Provide and post the vessel's stability letter.
Due 27 February 2009
Resolved 27 February 2009
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 20 February 2009
Resolved
Provide a means for logging the vessel's draft prior to each departure.
Due 27 February 2009
Resolved 27 February 2009
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 February 2009
Resolved
Provide and post a lifejacket donning placard.
Due 27 February 2009
Resolved 27 February 2009
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 21 February 2008
Resolved
Label PFD storage bins
Condition: Unknown
Due 21 February 2008
Resolved 21 February 2008
Resolution: Corrected
Lifesaving › Visual Distress Signals (General) › Expired
Issued 21 February 2008
Resolved
Replace expired visual distress signals.
Condition: Unknown
Due 21 February 2008
Resolved 21 February 2008
Resolution: Corrected.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 February 2008
Resolved
Remount water light bracket.
Condition: Unknown
Due 21 February 2008
Resolved 21 February 2008
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 February 2008
Resolved
Remove PFD's and clean mold off PFD's.
Condition: Unknown
Due 21 February 2008
Resolved 21 February 2008
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 January 2007
Resolved
Life Jacket storage requires labeling to indicate location of Child Life Jacket
Action required: 705 - Other - as specified
Due 13 February 2007
Resolved 4 January 2008
Resolution: Lockers are now labeled.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 January 2003
Resolved
Vee and weld possible cracked weld IWO bulkhead btw P & S voids of #2 compt. May just be that the paint is cracked and rust is bleeding making it appear to be cracked.
Condition: Unknown
Due 14 February 2003
Resolved 5 February 2003
Resolution: THIS TURNED OUT TO BE ONLY RUNNING RUST FROM A CRACK IN THE PAINT. NO CRACK FOUND IN WELD.
Construction/Loadline › Hull
Issued 14 January 2003
Resolved
Clean all void space bilges of water and debris. LEGACY COMPONENT DESC: Bilges
Due 14 February 2003
Resolved 5 February 2003
Resolution: ALL VOID SPACE BILGES CLEANED OF WATER AND DEBRIS.