B 31 is a 2006 tank barge. The Coast Guard has recorded 30 inspections since 2006, most recently in July 2026, along with 8 deficiencies and 1 casualty investigation in 2012.
Records from 2006 to 2026. Most recent: inspection, 21 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1933 - Simplified, Net Ton 1933 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 30
21 July 2026Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8440770
10 August 2025Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8206588
21 October 2024Load Line/Change of Employment · COI Inspection · Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8021206
29 August 2024Load Line/Change of Employment
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7992173
7 September 2023Internal Structural Exam · Cargo Tank Internal · Load Line/Change of Employment · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7780150
4 November 2022Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7588828
28 September 2021Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7318365
16 September 2020Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7047852
19 September 2019Examination of Repairs · Periodic Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6792753
16 October 2018Examination of Repairs · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6562507
21 September 2018Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6565894
Each opening in an exposed weather deck must -
(1) Have a coaming that complies with the height requirements in table 171.124(d); and
(2) Have a means for closing it weathertight.
Marine Inspector identified void hatches (#2 & #3 stbd side & #2 & #5 port side) that were not sealing properly after conducting chalk test. Additionally knife edges are getting thin due to corrosion.
46 CFR 171.122(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2022
Resolved 10 November 2022
Resolution: New gasket material was installed on hatches identified and conducted chalk test verifying proper closure.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 September 2019Resolved
DEFICIENCY CODE: 07116
MI found broken flame screens for cargo holds #1, #2 and #3. Replace to the satisfaction of attending MI.
46 CFR 35.30-10
ACTION:701
ACTION CODE:C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 September 2019
Resolution: New flame screens installed, deficiency corrected to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 September 2019Resolved
DEFICIENCY CODE: 02108
MI found at OPS House electrical junction box with out cover. Install cover to attending MI satisfaction.
46 CFR 111.81-1
ACTION: 701
ACTION CODE:C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2019
Resolution: Junction box cover installed, deficiency corrected to the satisfaction of the attending MI.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 September 2019Resolved
DEFICIENCY CODE: 06106
Cargo hoses found missing MAWP. Mark hoses to the satisfaction of attending MI.
33 CFR 154.500(f)(1)
ACTION: 701
ACTION CODE: C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2019
Resolution: Cargo hoses marked properly, deficiency corrected to the satisfaction of the attending MI.
DEFICIENCY CODE: 03105
MI found hatches dogs and latches components wasted on voids #3, #4, #5 and #6. Repair to attending MI satisfaction.
46 CFR 174.100
ACTION:701
ACTION CODE:C
ACTION:701
ACTION CODE:C
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2019
Resolution: New hatch components installed, deficiency corrected to the satisfaction of the attending MI.
Engineering › Lubricating Oil Service System › Hose
Issued 9 December 2014Resolved
Properly replace hydraulic hose for the bow thruster (fitting is pitting necked down). 46CFR32.65-1
Action required: 705 - Other - as specified
Due 9 January 2015
Resolved 15 December 2014
Resolution: Hose replaced with brand new one.
Engineering › Thrusters › Hose
Issued 9 December 2014Resolved
Install chaffing gear between hydraulic hoses in bow thruster. 46CFR32.35-1
Action required: 705 - Other - as specified
Due 9 January 2015
Resolved 15 December 2014
Resolution: hydraulic hoses have chafing gear.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 December 2006Resolved
Vessel shall not conduct any cargo operations until Vessel Response Plan is APPROVED.
Action required: 705 - Other - as specified
Resolved 1 December 2008
31 January 2012Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4235464
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.