MAURY USCG vessel records
← All vessels

CAPTAINS LADY III

CAPTAINS LADY III is a 2006 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in November 2025, along with 28 deficiencies and 1 casualty investigation in 2019.

Records from 2016 to 2025. Most recent: inspection, 12 November 2025.

Built
2006
Last inspected
12 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 November 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5706
849712
Flag
UNITED STATES
Maury page id
psix-849712

Documentation record

Registered dimensions (L × B × D)82.6 ft × 23.0 ft × 9.3 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)82.6 ft × 23.0 ft × 9.3 ft
ITC tonnagegross 146 / net 55
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST THOMAS, VI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
55 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
146 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT GEORGE Passenger (Inspected) · MISLE 44229 · 17 August 2019 · activity 6786760

Inspection history · 18

12 November 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8267234
8 September 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8231710
26 September 2024 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8003198
16 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7896361
22 September 2023 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7787587
6 April 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7663868
20 September 2022 Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7546348
6 October 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7327507
28 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7184896
6 October 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7072153
10 December 2019 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6871033
24 October 2019 Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6835413
17 August 2019 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6786760
24 October 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6570607
12 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539024
11 November 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6314197
25 September 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6272668
24 October 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6028708

Deficiency record · 28

04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 13 November 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.Emergency procedures were not present during inspection. Provide emergency instructions and post at the operating station. 46 CFR 185.510
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2025
Resolved 18 November 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2025 Resolved
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. 01 Crew member was not listed in current drug testing program. Provide evidence of crew members drug testing 46 CFR 16.210
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2025
Resolved 16 December 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2025 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] label on escape hatch, Provide label. 46 CFR 185.606
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 21 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2025 Resolved
Each life jacket kept in a stowage container must be readily available. Several life jackets were stowed within individual plastic wrapping. Remove plastic wrapping from PFD's to ensure readily available.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 November 2025
Resolved 18 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2025 Resolved
A bilge pipe in a vessel of more than 19.8 meters (65 feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. PVC strainer fwd of crash bulkhead was made of PVC and fell off during bilge pump testing. Replace strainer with suitable metal type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 16 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 September 2024 Resolved
The equipment required for life floats and buoyant apparatus must meet the following specifications: (1) Lifeline and pendants. The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. (2) Paddle. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant.....(4) Light. The light must be a floating water light approved under approval series 161.010 or other standard specified by the Commandant. The floating water light must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Life float pendants were found to be coiled and zip tied, life float paddles were not lashed to the life float to which they belong, and multiple water light lanyards were approximately 12 feet or less. Configure life floats in accordance with 46 CFR 180.175 to the satisfaction of attending marine inspector. 46 CFR 180.175(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 10 October 2024
Resolution: New lines for life float water lights were installed to match correct length, life float pendants were coiled and secured with a zip tie with a breaking strength of less than 18 lbs, and paddles were properly lashed to life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 September 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. None of the life float paddles were marked with the vessel's name. Mark life float paddle's with vessel's name to the satisfaction of attending marine inspector. 46 CFR 185.604(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 10 October 2024
Resolution: Vessel life float paddles were marked with the vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 September 2024 Resolved
Except for a storage battery used in a rescue boat, each battery without an expiration date indicated on it or for which the owner or managing operator does not have a record of the expiration date, used in an item of lifesaving equipment, must be replaced during the annual inspection. The water light batteries for the life floats and ring buoys did not have expiration dates marked on the batteries. Renew water light batteries to the satisfaction of the attending marine inspector. 46 CFR 185.726(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 10 October 2024
Resolution: Life float water lights were all replaced for the life floats, and the final battery for the ring life buoy water light was ordered with proof of order and anticipated delivery provided by vessel rep.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 September 2024 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Owner was unable to provide servicing records of fire extinguishing systems. Provide annual servicing records to the attending marine inspector. 46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2024
Resolved 23 January 2025
Resolution: Owner had CO2 cylinders hydro tested and re-installed on the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 September 2024 Resolved
A penetration in a watertight bulkhead must be... made watertight. Marine inspectors found penetrations in the 2nd and 3rd watertight bulkheads that were not watertight. Make bulkhead penetrations watertight to the satisfaction of the attending marine inspector. 46 CFR 179.320(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2024
Resolved 10 October 2024
Resolution: Bulkhead penetrations were satisfactorily filled to prevent movement of water through bulkhead penetrations.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2023 Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crew member assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Owner/Operator did not have information posted on board vessel. Must provide information to crew members. 46 CFR 16.401(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2023
Resolved 10 October 2024
Resolution: Vessel rep posted EAP information on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 September 2023 Resolved
Each buoyant apparatus must have Type II retro-reflective material meeting subpart 164.018 of this chapter on each side and end. All buoyant apparatuses have worn retro-reflective tape that needs to be replaced. 46 CFR 160.010-4(p)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Received photos that satisfy deficiency, see documents.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 September 2023 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under 46 CFR 185.722. 46 CFR 185.702(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Received photos that satisfy deficiency, see documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 September 2023 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10. 46 CFR 176.810(b)(2)(iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Received photos that satisfy deficiency, see documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2023 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). No spanner wrench was on board. 46 CFR 181.310(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2023
Resolved 13 October 2023
Resolution: Received photos that satisfy deficiency, see documents.
14 - Pollution Prevention › N/A - No Subsystem › VGP: Records/Logs
Issued 22 September 2023 Resolved
Inspectors must also consider the results of the past year’s visual and analytical monitoring when planning and conducting inspections. Owner/Operator did not know they needed a VGP, thus they did not have one. Must obtain VGP documents. VGP Parts 3, 4.2 para 3 CG-543 Policy Letter 11-01
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2023
Resolved 9 November 2023
Resolution: Received email from Owner stating their attempt to contact EPA to acquire VGP,See "Documents".
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 September 2022 Resolved
The pump outlet must be fitted with a pressure gauge. Gauge found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 23 September 2022
Resolution: O/O replaced gauge with new and tested SAT. Pressure rised to 80 PSI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 September 2022 Resolved
The Rules concerning lights (§§ 83.20 through 83.31) shall be complied with from sunset to sunrise and in restricted visibility and may be exhibited in all other circumstances when it is deemed necessary.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 23 September 2022
Resolution: O/O replaced LED bulbs with new. Tested SAT.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 October 2019 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: (i)The vital systems listed in 182.710 of this chapter; (ii) Interior lighting except for decorative lights; (iii) Communication systems including a public address system required under 184.610 of this chapter; and (iv) Navigation equipment and lights. Marine Inspector observed not all required equipment above was operational on back up power. Rectify prior to carrying passengers.
Action required: 60 - Rectify deficiencies prior to movement
Due 23 November 2019
Resolved 10 December 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 October 2019 Resolved
A station bill must be posted by the master on a vessel of more than 65 feet in length having a Certificate of Inspection requiring more than four crew members at any one time, including the master. The vessel did not have a station bill.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2019
Resolved 10 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018 Resolved
Vsl is broadcasting Invalid Call Sign and Vsl is broadcasting greater than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 October 2020
Resolution: Attended vessel for annual inspection. Verified that vessels proper callsign was transmitting via AIS.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 26 January 2018 Resolved
Pitting found in LAZ forward bulkhead IWO the keel. Once ground out, clad welding has been approved of 02 pits which have been identified.
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 24 October 2018
Resolution: See activity # 6272668
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 January 2018 Resolved
Holes found in sewage piping throughout eng room. Proposed repair of cutting sections of piping and replacing with PVX with metallic penetrations through W/T bulkheads determined to be SAT. Complete repair to satisfaction of attending MI.
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 24 October 2018
Resolution: See activity # 6272668
Engineering › Bilge Water Management System › Strainer
Issued 25 September 2017 Resolved
Bilge strainer in lazarette wasted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 22 November 2017
Resolution: Vessel rep. replaced bilge strainer.
Construction/Loadline › Penetrations › Gasket
Issued 25 September 2017 Resolved
Fill cable penetration in aft engine room bulkhead.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 22 November 2017
Resolution: Vessel rep filled cable penetration in aft engine room bulkhead.
Engineering › Bilge Water Management System › Interface Detector
Issued 25 September 2017 Resolved
Replace bilge alarm in forepeak.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 24 October 2018
Resolution: Replaced and worked properly.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 24 October 2016 Resolved
There were no servicing records for portable fire extinguishers. Provide.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 15 December 2016
Resolution: Received photograph of servicing record from operator.
Lifesaving › Lifefloat › Paddle
Issued 24 October 2016 Resolved
03 paddles were not serviceable. Replace.
Action required: 705 - Other - as specified
Due 7 November 2016
Resolved 15 December 2016
Resolution: Received photograph of 03 paddles from operator.

Casualty record · 1

17 August 2019Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 6786760
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.