MAURY USCG vessel records Sign in
← All vessels

OCEAN DISCOVERY

OCEAN DISCOVERY is a 2006 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 2006, most recently in September 2025, along with 59 deficiencies, 1 operational control and 16 casualty investigations between 2011 and 2023.

Records from 2006 to 2025. Most recent: inspection, 17 September 2025.

Built
2006
Last inspected
17 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ9547
850050
Flag
UNITED STATES
367580000, 368472170
Maury page id
psix-850050

Inspections, by type

…with no type recorded13
Years with a record 18 calendar years (2006–2025)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.4 ft × 26.9 ft × 8.5 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)65.4 ft × 26.9 ft × 8.5 ft
ITC tonnageNot recorded
BuilderISLAND BOATS, INC. · JEANERETTE, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKODIAK, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
41 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9547MMSI 368472170 · active · compulsorily equipped · granted 6 May 2026, expires 6 May 2036
WDD4259MMSI 367580000 · active · compulsorily equipped · granted 9 September 2016, expires 28 September 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAUI PRINCESS Passenger (Inspected) · MISLE 50291 · 28 July 2015 · activity 5201498

Inspection history · 60

17 September 2025 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8236408
13 August 2025 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8194542
1 October 2024 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8012875
16 February 2024 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7875299
26 October 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7814957
15 September 2023 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7786288
7 February 2023 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7633541
3 February 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7643620
27 October 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7584605
12 September 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7542040
15 May 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7476938
3 February 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7414499
2 November 2021 Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362167
5 October 2021 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7327203
8 September 2021 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7307877
5 May 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7214710
7 October 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7073397
26 July 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7029674
8 January 2020 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6891858
1 January 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6884628
29 November 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6884470
28 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6866680
25 November 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6862540
22 October 2019 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6839721
5 September 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6804254
28 November 2018 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6588762
16 November 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6581767
18 October 2018 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6564667
7 June 2018 Drydock Exam · Damage Survey · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6431805
20 April 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6395842
20 March 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6374914
27 November 2017 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6313716
6 November 2017 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6304741
29 June 2017 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6191336
6 October 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6010765
6 June 2016 Internal Structural Exam · Drydock Exam · In-Service Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5895837
28 January 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5806236
3 January 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5790825
17 November 2015 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5788214
28 July 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5201498
22 October 2014 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5010475
22 October 2014 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5010485
3 June 2014 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4877781
29 May 2014 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4885262
14 May 2014 Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4862679
9 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4306844
20 September 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4150306
20 September 2011 Damage Survey · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4150311
13 October 2010 Internal Structural Exam · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3869164
1 October 2008 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3336879
28 May 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3220385
13 May 2008 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3205652
26 February 2008 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3154241
5 December 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3110078
1 November 2007 Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3097873
12 October 2007 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3078878
14 September 2007 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3058002
18 May 2007 Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 2938485
20 March 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2891520
15 February 2006 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification · Internal Structural Exam · Deadweight Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2788162

Deficiency record · 59

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 August 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all interior spaces to ensure that they are adequately ventilated and drained, and that means of escape are adequate and properly maintained. Ladder in port side aftmost space is deteriorated. Repair or replace ladder to the satisfaction of the attending Marine Inspector. 46 CFR 176.802(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 17 September 2025
Resolution: Ladder replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 October 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Pin hole leak located on portion of port fire main piping. Soft patch covering leak. Repair damaged piping to provide leak free system from port fire main. Test fire main to ensure system operating at 60psi working pressure. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2024
Resolved 7 October 2024
Resolution: Repaired leak with new aluminum fitting. No observed leaks.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 October 2023 Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. FCC Safety Radio Certificate not issued by FCC licensed technician for radio installation. Provide inspection and valid FCC Safety Radio Certificate. 46 CFR 176.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2023
Resolved 6 December 2023
Resolution: New FCC Safety Radio Cert provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 27 October 2022 Resolved
FCC requires mariners that operate a vessel with more than 6 passengers to have a valid FFC Marine Radio Operator Permit(MROP). Vessel master did not have FCC MROP. Master shall provide MROP. 47 CFR 13.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2022
Resolved 6 November 2022
Resolution: MROP provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 October 2022 Resolved
Materials used in piping systems must meet the requirements of 182 subpart G and be acceptable to the [name withheld] main had leak at coupling in port engine room. Provide new piping to make fire main leak free. 46 CFR 182.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2022
Resolved 6 November 2022
Resolution: Pressure regulating valve installed. No leaks detected at correct pressure.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 October 2022 Resolved
The Life Float Light must be attached by 3/8 inch lanyard, resistant to UV, and at least 18 feet in length. Life Float light line deteriorated and not of proper length. Provide new line that meets length. 46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2022
Resolved 6 November 2022
Resolution: New line of proper length provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all supervisory personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 30 November 2021
Resolution: Supervisors completed required EAP Training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2021 Resolved
Diesel fuel shutoff valve must be manually operable from outside the compartment in which the valve is located. Starboard side remote fuel shut of handle and cable did not operate valve inside the compartment. 46 CFR 182.455(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Remote fuel shutoff operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2021 Resolved
Vital piping system may not have any leaks and shall be operational as designed and approved. Fire pump sea chest to first valve had leak with unknown source. Secure leak and conduct testing to ensure leak has been eliminated. 46 CFR 182.100 46 CFR 182.710
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: eliminated leak from fire pump sea chest piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2021 Resolved
Electrical equipment on vessel must be maintained to protect crew and others from electrical shock/fire. The shore power connection box must be interlocked with the vessels power sources. Distribution panel could not be closed causing interlock to not be operational. This open panel was also a fire safety and a personal safety hazard. 46 CFR 183.200 46 CFR 183.390
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Shorepower panel properly closed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 October 2021 Resolved
Fixed bilge pump must be self priming and operational. Fixed bilge pump was not operational. Provide operational fixed bilge pump. 46 CFR 182.520 46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Fixed bilge pump operational.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 October 2021 Resolved
A self priming fire pump must be installed and operational on vessels over 65 feet. Fire pump would not operate. Provide operational fire pump. 46 CFR 181.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Fire pump operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 October 2021 Resolved
Visual and audible bilge high level alarms must be provided on vessel over 26 ft. Audible bilge high level alarms not operational. Provide operational audible high level alarms. 46 CFR 182.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Audible alarms operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 October 2021 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicators for automatic bilge pumps where not operational. 46 CFR 182.530(C)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Visual indicator provided.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 October 2021 Resolved
All equipment must be installed and maintained in such a manner as to afford adequate protection from personnel injury. Engine room deck plating missing throughout entire engine room and specifically over rotating shaft. Provide engine room deck plating. 46 CFR 182.100 46 CFR 177.960
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Deck plating provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 October 2021 Resolved
A vessel must carry one ring buoy floating waterlight. Ring buoy waterlight not operational. Batteries missing. Provide operational ring buoy waterlight. Restricted from nighttime operations. 46 CFR 180.70(d)
Action required: 705 - Other - as specified
Resolved 19 October 2021
Resolution: Ring buoy light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 October 2021 Resolved
Each life float must be fitted with an operational light. Life float light not operational. Provide operational life float light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Life float light operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2021 Resolved
Each vessel must have permanent draft marks at each end of the vessel or permanent loading marks placed on each side of the vessel forward and aft in contrasting color and 1 inch in height. Draft/loading marks missing. Provide hull markings. 46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Draft marks provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 October 2021 Resolved
Each survival craft/life float must be of good quality for its purpose intended. Lifeline pendent connection points on 02 life floats worn/damaged beyond repair. Provide 02 new CG approved life floats. 46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: New life floats provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 October 2021 Resolved
Remote fuel shutoff station must be marked in clearly legible letters at least 1 inch high indication purpose of the valve and direction of operation. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Marking provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 October 2021 Resolved
Each EPIRB must be tested monthly and shall be logged or otherwise documented. EPIRB testing was not logged. Provide log showing EPIRB testing completed. 46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: EPIRB test logged.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 5 October 2021 Resolved
All equipment must be installed on and maintained in such a manner as to afford adequate protection from causing personnel injury. Generator lagging/exhaust not supported/falling making hot piping exposed. Provide proper shielding/lagging on generator exhaust. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Generator lagging provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2021 Resolved
Cooking system using gas must be mounted in accordance with ABYC A-1. Propane bottles not mounted and rolling on their sides. Provided mounted bottles. 46 CFR 184.240(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Propane bottles mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2021 Resolved
At each COI galleys and similar spaces may be examined to determine that they are in a sanitary condition. Outdoor grills had infestation of cockroaches and grease. Clean space and exterminate bug population. No use of grill until area cleaned and infestation removed. 46 CFR 176.818
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Space cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2021 Resolved
All machinery must be installed and maintained in such a manner to afford adequate protection from causing machinery failure. Oil return for CCV on starboard side engine inboard showing excessive corrosion at oil pan connection. Both fitting and pan showing corrosion. Make repairs to fitting and oil pan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 12 November 2021
Resolution: New fitting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2021 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Blue Sea terminal board under bridge console fitted with blade type fuses. 46CFR183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2021
Resolution: Catridge fuses provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2020 Resolved
Found dead-end wire in Port side fuel tank space. Vessel must protect crew from electrical hazards caused by originating in electrical equipment and electrical shock. Remove dead and wire in Port side fuel tank space after the first.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Dead end wire removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2020 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Steering unit piping under helm at the operating station was leaking hydraulic fluid. Repair Hydraulic fluid leak on steering unit piping at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Repair made to hydraulic line.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2020 Resolved
The controls for the various fire extinguishing systems must be marked conspicuously. Bilge pump and fire pump labels incorrectly marked at operating station. Properly label the bilge pump and fire pump controls at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Systems labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2020 Resolved
In accordance with work instruction 31 to reduce crew members operational AED device is required. AED pads were missing in AED device. Provide operatioanl AED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: AED pads provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 October 2020 Resolved
The maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Max passenger upper deck limit not labeled. Label max passenger upper deck limit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Upper limit marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2020 Resolved
Liquid present in battery containers starboard void and starboard engine room. Make battery containers dry.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Battry containers cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2020 Resolved
No fire ax on board. Provide fire ax.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Fire axe provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2019 Resolved
Upper deck fire hose was unsatisfactory. Renew in acordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 25 November 2019
Resolution: Hose renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2019 Resolved
Port emergency fuel shutoff valve did not close completely. Prove correct operation of valve in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 25 November 2019
Resolution: Valve closed completely.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 October 2019 Resolved
1 22 person lifefloat was unsatisfactory due to sun damage/fading. Renew/repair lifefloat in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2019
Resolved 25 November 2019
Resolution: Life float repaired with manufacturer's recommended product.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 October 2018 Resolved
Pre-engineered system shall secure all engines that draw air from the protected space. Stbd Fireboy did not secure stbd generator when activated. Correct in accordance with 181.420.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 November 2018
Resolution: Generator secures upon system activation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 October 2018 Resolved
Testing of fire protection equipment. Ventilation closure did not close properly when tested. Repair in accordance with 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018
Resolution: Closures operated correctly.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 October 2018 Resolved
Testing of fuel shutoff valves. Stbd fule valve did not close completely. Repair in accordance with 182.455.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018
Resolution: Stbd fuel valve closed completely.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 October 2018 Resolved
Protection from personnel injury. Stbd generator belt guard was missing. Repair in accordance with 182.100.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018
Resolution: Stbd generator guard installed.
Lifesaving › Lifefloat › Serviceable
Issued 6 November 2017 Resolved
Outer covering of lifefloat was deteriorated. Renew/repair lifefloat in accordance with 46CFR 180.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 27 November 2017
Resolution: Lifefloat renewed.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 6 November 2017 Resolved
Fuel tank sight glasses were leaking. Repair/renew in accordance with 46CFR 182.435.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 27 November 2017
Resolution: Sight glasses repaired.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 29 June 2017 Resolved
Port eng shaft coupling weld sheared.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2017
Resolved 30 June 2017
Resolution: Shaft repaired and aligned.
Engineering › Bilge Water Management System › Not Operational
Issued 6 October 2016 Resolved
Port Hull installed system not operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2016
Resolution: Vessel went through entire system and found check not operating properly. Valves were overhauled and proper operation was witnessed.
Lifesaving › Hand Flares › Storage
Issued 6 October 2016 Resolved
Distress signals container was not adequate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2016
Resolution: Vessel installed new properly marked and water tight container.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 6 October 2016 Resolved
The company has a huge employ base. It is tough for them to train everyone however I explained the intent of the reg which is every crewmember does required drills once a quarter.
Due 7 October 2016
Resolved 7 October 2016
Resolution: Company has a good training program which requires monthly drills.
Fire Fighting › Fire Pumps › Pressure
Issued 6 October 2016 Resolved
Fire pump did not meet the required PSI of 60 however it did meet the gallons.
Due 6 November 2016
Resolved 6 November 2016
Resolution: Vessel replaced fire pump with new one and it meets required PSI.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 28 January 2016 Resolved
Vessel to provide twin disc technical report identifying and resolving the causes for loss of propulsion at operating stations. Provide diagnostic scan report. Conduct at sea engine and throttle control trials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2016
Resolution: Tech Rep was on board and showed all codes and gave recommendations on how to remove stray voltage and replaced stbd throttle cable connection. Sea trials all sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 November 2015 Resolved
Coast Pilot not onboard.
Due 17 December 2015
Resolved 17 November 2015
Resolution: Vessel printed new copy of required section.
Fire Fighting › Fire Pumps › Pressure
Issued 17 November 2015 Resolved
Pressure regulating valve did not operate properly. System could not achieve required pressure 60psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2015
Resolution: Vessel had to manually tighten pressure regulator to achieve pressure. Vessel is installing new valve.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 22 October 2014 Resolved
Make permanent repairs to starboard propulsion system in accordance with submitted repair proposal and complete sea trials to the satisfaction of the cognizant OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2014
Resolution: Vessel installed new grade 10 bolts in both shaft couplings.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 20 September 2011 Resolved
Attended vsl after Master described immediate loss of oil pressure in strd engine. Oil was discovered in the bilge and all over the inboard side of the strd engine. Could not immediately identify cause of leaked oil due to the amount of oil covering the entire inboard side of the strd engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2011
Resolved 23 September 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 October 2010 Resolved
Provide device to automatically shut down generator located in the stbd engine room prior to release of extinguishing agent. (46 CFR 181.410(b)(10)).
Action required: 705 - Other - as specified
Due 22 October 2010
Resolved 26 October 2010
Construction/Loadline › Hull › Transverse Frame
Issued 1 October 2008 Resolved
Repair broken welds (2) iwo deck beams as marked in fwd midship wing deck compartment and (1) stringer/hull weld aft of aftmost frame in stbd fuel tank space.
Due 24 October 2008
Resolved 22 October 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 December 2007 Resolved
RENEW AS ORIGINAL RAIL FOR STBD. LADDER
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 January 2008
Resolved 24 December 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 October 2007 Resolved
Conduct repairs to the automatic shut down system for the fixed firefighting on the port and starboard engines. Complete repairs and prove the operability of the system to the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2007
Resolved 13 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 14 September 2007 Resolved
Complete repairs to the hull in the way of the forward part of the wing deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2007
Resolved 26 November 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 14 September 2007 Resolved
Complete repairs to the starboard engine and perform sea trials to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2007
Resolved 24 September 2007
Resolution: Conducted satisfactory underway sea trials.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 February 2006 Resolved
Provide passenger seating per MSC approved general arrangement plan. Seat brackets are in place mounted to main deck ready for attachment of seating.
Action required: 705 - Other - as specified
Due 15 December 2006
Resolved 5 December 2007
Resolution: Met the MSC seating criteria under general arrangement plan.

Casualty record · 16

20 September 2011Routine · role: Involved in a Marine Investigation (non-casualty) · activity 4150306
16 December 2012Routine · role: Involved in a Marine Casualty · activity 4503762
25 February 2013Routine · role: Involved in a Marine Casualty · activity 4562082
26 December 2013Routine · role: Involved in a Marine Casualty · activity 4774797
29 December 2013Routine · role: Involved in a Marine Casualty · activity 4775786
21 January 2014Routine · role: Involved in a Marine Casualty · activity 4788105
8 September 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4979172
19 March 2015Routine · role: Involved in a Marine Casualty · activity 5093444
3 January 2016Routine · role: Involved in a Marine Casualty · activity 5790825
20 April 2018Routine · role: Acknowledged Pollution Source · activity 6395842
29 November 2019Routine · role: Involved in a Marine Casualty · activity 6884470
26 July 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7029674
5 May 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7214710
3 February 2022Routine · role: Alleged Pollution Source · activity 7414499
15 May 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7476938
3 February 2023Routine · role: Involved in a Marine Casualty · activity 7643620
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.