Records from 2011 to 2025. Most recent: inspection, 17 September 2025.
Inspection history · 38
17 September 2025
Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8236408
13 August 2025
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8194542
1 October 2024
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8012875
16 February 2024
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7875299
26 October 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7814957
15 September 2023
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7786288
7 February 2023
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7633541
3 February 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7643620
27 October 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7584605
12 September 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7542040
15 May 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7476938
3 February 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7414499
2 November 2021
Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7362167
5 October 2021
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7327203
8 September 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7307877
5 May 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7214710
7 October 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7073397
26 July 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7029674
8 January 2020
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6891858
1 January 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6884628
29 November 2019
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6884470
28 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6866680
25 November 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6862540
22 October 2019
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6839721
5 September 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6804254
28 November 2018
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6588762
16 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6581767
18 October 2018
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6564667
7 June 2018
Drydock Exam · Damage Survey · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6431805
20 April 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6395842
20 March 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6374914
27 November 2017
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6313716
6 November 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6304741
29 June 2017
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6191336
6 October 2016
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6010765
6 June 2016
Internal Structural Exam · Drydock Exam · In-Service Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5895837
28 January 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5806236
3 January 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5790825
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 August 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all interior spaces to ensure that they are adequately ventilated and drained, and that means of escape are adequate and properly maintained. Ladder in port side aftmost space is deteriorated. Repair or replace ladder to the satisfaction of the attending Marine Inspector.
46 CFR 176.802(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2025
Resolved 17 September 2025
Resolution: Ladder replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 October 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Pin hole leak located on portion of port fire main piping. Soft patch covering leak. Repair damaged piping to provide leak free system from port fire main. Test fire main to ensure system operating at 60psi working pressure. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2024
Resolved 7 October 2024
Resolution: Repaired leak with new aluminum fitting. No observed leaks.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 October 2023
Resolved
The owner or managing operator of a vessel shall ensure that the vessel complies with the laws and regulations applicable to the vessel and that the vessel is otherwise satisfactory for the intended service. The initial inspection may include an inspection of the following items: Certificates and operating manuals, including certificates issued by the FCC. FCC Safety Radio Certificate not issued by FCC licensed technician for radio installation. Provide inspection and valid FCC Safety Radio Certificate.
46 CFR 176.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 November 2023
Resolved 6 December 2023
Resolution: New FCC Safety Radio Cert provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 27 October 2022
Resolved
FCC requires mariners that operate a vessel with more than 6 passengers to have a valid FFC Marine Radio Operator Permit(MROP). Vessel master did not have FCC MROP. Master shall provide MROP.
47 CFR 13.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2022
Resolved 6 November 2022
Resolution: MROP provided.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 October 2022
Resolved
Materials used in piping systems must meet the requirements of 182 subpart G and be acceptable to the [name withheld] main had leak at coupling in port engine room. Provide new piping to make fire main leak free.
46 CFR 182.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2022
Resolved 6 November 2022
Resolution: Pressure regulating valve installed. No leaks detected at correct pressure.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 October 2022
Resolved
The Life Float Light must be attached by 3/8 inch lanyard, resistant to UV, and at least 18 feet in length. Life Float light line deteriorated and not of proper length. Provide new line that meets length.
46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2022
Resolved 6 November 2022
Resolution: New line of proper length provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all supervisory personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2021
Resolved 30 November 2021
Resolution: Supervisors completed required EAP Training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2021
Resolved
Diesel fuel shutoff valve must be manually operable from outside the compartment in which the valve is located. Starboard side remote fuel shut of handle and cable did not operate valve inside the compartment.
46 CFR 182.455(b)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Remote fuel shutoff operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2021
Resolved
Vital piping system may not have any leaks and shall be operational as designed and approved. Fire pump sea chest to first valve had leak with unknown source. Secure leak and conduct testing to ensure leak has been eliminated.
46 CFR 182.100
46 CFR 182.710
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: eliminated leak from fire pump sea chest piping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2021
Resolved
Electrical equipment on vessel must be maintained to protect crew and others from electrical shock/fire. The shore power connection box must be interlocked with the vessels power sources. Distribution panel could not be closed causing interlock to not be operational. This open panel was also a fire safety and a personal safety hazard.
46 CFR 183.200
46 CFR 183.390
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Shorepower panel properly closed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 October 2021
Resolved
Fixed bilge pump must be self priming and operational. Fixed bilge pump was not operational. Provide operational fixed bilge pump.
46 CFR 182.520
46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Fixed bilge pump operational.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 October 2021
Resolved
A self priming fire pump must be installed and operational on vessels over 65 feet. Fire pump would not operate. Provide operational fire pump.
46 CFR 181.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Fire pump operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 October 2021
Resolved
Visual and audible bilge high level alarms must be provided on vessel over 26 ft. Audible bilge high level alarms not operational. Provide operational audible high level alarms.
46 CFR 182.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Audible alarms operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 October 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Indicators for automatic bilge pumps where not operational.
46 CFR 182.530(C)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Visual indicator provided.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 October 2021
Resolved
All equipment must be installed and maintained in such a manner as to afford adequate protection from personnel injury. Engine room deck plating missing throughout entire engine room and specifically over rotating shaft. Provide engine room deck plating.
46 CFR 182.100
46 CFR 177.960
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Deck plating provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 October 2021
Resolved
A vessel must carry one ring buoy floating waterlight. Ring buoy waterlight not operational. Batteries missing. Provide operational ring buoy waterlight.
Restricted from nighttime operations.
46 CFR 180.70(d)
Action required: 705 - Other - as specified
Resolved 19 October 2021
Resolution: Ring buoy light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 October 2021
Resolved
Each life float must be fitted with an operational light. Life float light not operational. Provide operational life float light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2021
Resolution: Life float light operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2021
Resolved
Each vessel must have permanent draft marks at each end of the vessel or permanent loading marks placed on each side of the vessel forward and aft in contrasting color and 1 inch in height. Draft/loading marks missing. Provide hull markings.
46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Draft marks provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 October 2021
Resolved
Each survival craft/life float must be of good quality for its purpose intended. Lifeline pendent connection points on 02 life floats worn/damaged beyond repair. Provide 02 new CG approved life floats.
46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: New life floats provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 October 2021
Resolved
Remote fuel shutoff station must be marked in clearly legible letters at least 1 inch high indication purpose of the valve and direction of operation.
46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Marking provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 October 2021
Resolved
Each EPIRB must be tested monthly and shall be logged or otherwise documented. EPIRB testing was not logged. Provide log showing EPIRB testing completed.
46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: EPIRB test logged.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 5 October 2021
Resolved
All equipment must be installed on and maintained in
such a manner as to afford adequate protection from
causing personnel injury. Generator lagging/exhaust not supported/falling making hot piping exposed. Provide proper shielding/lagging on generator exhaust.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Generator lagging provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2021
Resolved
Cooking system using gas must be mounted in accordance with ABYC A-1. Propane bottles not mounted and rolling on their sides. Provided mounted bottles.
46 CFR 184.240(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Propane bottles mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2021
Resolved
At each COI galleys and similar spaces may be examined to determine that they are in a sanitary condition.
Outdoor grills had infestation of cockroaches and grease. Clean space and exterminate bug population. No use of grill until area cleaned and infestation removed.
46 CFR 176.818
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 19 October 2021
Resolution: Space cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2021
Resolved
All machinery must be installed and maintained in such a manner to afford adequate protection from causing machinery failure. Oil return for CCV on starboard side engine inboard showing excessive corrosion at oil pan connection. Both fitting and pan showing corrosion. Make repairs to fitting and oil pan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 12 November 2021
Resolution: New fitting installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2021
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. Blue Sea terminal board under bridge console fitted with blade type fuses.
46CFR183.380(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 October 2021
Resolution: Catridge fuses provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2020
Resolved
Found dead-end wire in Port side fuel tank space. Vessel must protect crew from electrical hazards caused by originating in electrical equipment and electrical shock. Remove dead and wire in Port side fuel tank space after the first.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Dead end wire removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Steering unit piping under helm at the operating station was leaking hydraulic fluid. Repair Hydraulic fluid leak on steering unit piping at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Repair made to hydraulic line.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2020
Resolved
The controls for the various fire extinguishing systems must be marked conspicuously. Bilge pump and fire pump labels incorrectly marked at operating station. Properly label the bilge pump and fire pump controls at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Systems labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2020
Resolved
In accordance with work instruction 31 to reduce crew members operational AED device is required. AED pads were missing in AED device. Provide operatioanl AED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: AED pads provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 October 2020
Resolved
The maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Max passenger upper deck limit not labeled. Label max passenger upper deck limit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Upper limit marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2020
Resolved
Liquid present in battery containers starboard void and starboard engine room. Make battery containers dry.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Battry containers cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2020
Resolved
No fire ax on board. Provide fire ax.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 12 November 2020
Resolution: Fire axe provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 October 2019
Resolved
Upper deck fire hose was unsatisfactory. Renew in acordance with 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 25 November 2019
Resolution: Hose renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2019
Resolved
Port emergency fuel shutoff valve did not close completely. Prove correct operation of valve in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2019
Resolved 25 November 2019
Resolution: Valve closed completely.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 22 October 2019
Resolved
1 22 person lifefloat was unsatisfactory due to sun damage/fading. Renew/repair lifefloat in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2019
Resolved 25 November 2019
Resolution: Life float repaired with manufacturer's recommended product.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 October 2018
Resolved
Pre-engineered system shall secure all engines that draw air from the protected space. Stbd Fireboy did not secure stbd generator when activated. Correct in accordance with 181.420.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 November 2018
Resolution: Generator secures upon system activation.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 October 2018
Resolved
Testing of fire protection equipment. Ventilation closure did not close properly when tested. Repair in accordance with 176.810.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018
Resolution: Closures operated correctly.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 October 2018
Resolved
Testing of fuel shutoff valves. Stbd fule valve did not close completely. Repair in accordance with 182.455.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018
Resolution: Stbd fuel valve closed completely.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 18 October 2018
Resolved
Protection from personnel injury. Stbd generator belt guard was missing. Repair in accordance with 182.100.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2018
Resolution: Stbd generator guard installed.
Lifesaving › Lifefloat › Serviceable
Issued 6 November 2017
Resolved
Outer covering of lifefloat was deteriorated. Renew/repair lifefloat in accordance with 46CFR 180.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 27 November 2017
Resolution: Lifefloat renewed.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 6 November 2017
Resolved
Fuel tank sight glasses were leaking. Repair/renew in accordance with 46CFR 182.435.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 27 November 2017
Resolution: Sight glasses repaired.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 29 June 2017
Resolved
Port eng shaft coupling weld sheared.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2017
Resolved 30 June 2017
Resolution: Shaft repaired and aligned.
Engineering › Bilge Water Management System › Not Operational
Issued 6 October 2016
Resolved
Port Hull installed system not operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2016
Resolution: Vessel went through entire system and found check not operating properly. Valves were overhauled and proper operation was witnessed.
Lifesaving › Hand Flares › Storage
Issued 6 October 2016
Resolved
Distress signals container was not adequate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2016
Resolution: Vessel installed new properly marked and water tight container.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 6 October 2016
Resolved
The company has a huge employ base. It is tough for them to train everyone however I explained the intent of the reg which is every crewmember does required drills once a quarter.
Due 7 October 2016
Resolved 7 October 2016
Resolution: Company has a good training program which requires monthly drills.
Fire Fighting › Fire Pumps › Pressure
Issued 6 October 2016
Resolved
Fire pump did not meet the required PSI of 60 however it did meet the gallons.
Due 6 November 2016
Resolved 6 November 2016
Resolution: Vessel replaced fire pump with new one and it meets required PSI.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 28 January 2016
Resolved
Vessel to provide twin disc technical report identifying and resolving the causes for loss of propulsion at operating stations. Provide diagnostic scan report. Conduct at sea engine and throttle control trials.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2016
Resolution: Tech Rep was on board and showed all codes and gave recommendations on how to remove stray voltage and replaced stbd throttle cable connection. Sea trials all sat.