Records from 1997 to 2024. Most recent: inspection, 3 June 2024.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 18.0 ft × 5.8 ft
Registered tonnagegross 29 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAXON CONSTRUCTION CO INC · TELL CITY, IN, UNITED STATES · built 1964
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Net Ton
29 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
3 June 2024
Administrative Inspection · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7926330
26 September 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7799093
26 October 2022
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7584290
13 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7332927
26 August 2020
Initial Certification · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7043132
24 June 2016
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6016615
10 February 2016
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5813250
23 November 2015
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 5770151
13 November 2012
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4487550
5 January 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4227511
10 September 2009
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 3607543
1 September 2006
Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 2801583
15 May 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1616996
22 March 2002
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1611996
12 March 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 24610
12 March 1997
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 401615
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2020
Resolved
Fire hose burst while testing hose
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2020
Resolution: Fire hose replaced
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 30 September 2020
Resolved
Paint handrail near the generator exhaust on the stern to indentify it as a dangerous area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2020
Resolution: Handrail near generator exhaust painted yellow
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 30 September 2020
Resolved
Install gaurd on the generator exhaust manifold
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2020
Resolution: Genset exhaust manifold guard installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2020
Resolved
Ring bouy line not secured around the body of the ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2020
Resolution: Ring bouy line bag retied around the body of the bouy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2020
Resolved
Relocate fuel shutoff cable to the main trunk line near the fuel tank
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2020
Resolution: Fuel shutoff cable relocated to the main trunk line near the fuel tank
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 September 2020
Resolved
2nd deck ladder chain under-sized
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 October 2020
Resolution: 2nd deck ladder chain replaced with a more substantial one
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 30 September 2020
Resolved
Master unable to produce FCC Radio Operator Permit
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Proof of Master's radio operator permit received