Records from 2006 to 2022. Most recent: inspection, 2 February 2022.
Inspection history · 14
2 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7389528
28 February 2019
Loadline Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6634451
28 February 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6637492
8 February 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6352106
6 July 2016
MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5932023
8 April 2016
MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5857524
16 April 2015
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5107285
9 January 2015
NPV Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5052115
30 December 2013
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4787222
12 December 2011
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4206368
7 December 2010
ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3892269
25 September 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2786409
21 September 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2784792
19 September 2006
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2780170
Documentation › Logs/Records › Garbage Recordkeeping
Issued 30 December 2013
Resolved
0190 - Ship's logbooks/compulsory entries - Every ship of 400 Gross Tons and above shall be provided with a garbage record book that is in the form specified in the Appendix to Annex V of MARPOL. Ship's garbage record book did not have correct format. Garbage receipts were not maintained IAW Appendix of Annex V. MARPOL Annex V/10.3
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2015
Resolution: Proper documentation provided.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 30 December 2013
Resolved
0190 - Ship's logbooks/compulsory entries - Each entry in the Garbage Record Book shall be made and signed on the date of discharge. Garbage Record Book entries were not made on the date of discharge. MARPOL Annex V/10.3.1
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2015
Resolution: Proper documentation provided.
Operations/Management › Pollution › Control of Garbage
Issued 19 September 2006
Resolved
No Garbage Management Plan located on board. No Garbage Management Placards onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 25 September 2006
Resolution: Garbage Management Plan and Placarding placed on board the barge.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 19 September 2006
Resolved
Garbage Record Book not being maintained properly. No signatures for discharge entries or Master/Foreman signature at the bottom of the page. GRB starts on page 7. Pages 1-6 of the GRB have been torn out. No garbage receipts on board. Marine Inspectors were informed the GRB was place on board 17SEP06 and the first recorded log entry started on 13APR06. See attached copies of the C/B ANNA 4's GRB
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Training provided to crew on how to maintain the Garbage Record Book.
Documentation › Logs/Records › Oil Record Book
Issued 19 September 2006
Resolved
Oil Record Book not being maintained properly. Long periods of time unaccounted for. Signatures missing for individual operations on pages 1 and 2. Master/Forman signature missing at the bottom of pages 1 and 2. Page 4 of the Oil Record Book is missing. See attached copies of the C/B ANNA 4's Oil Record Book.
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Training provided to crew on maintenance of the Oil Record Book.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 19 September 2006
Resolved
No oil discharge placards onboard.
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Discharge Of Oil Placarding placed onboard in proper locations.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 19 September 2006
Resolved
Electrical wiring running through a hole in the base of the door leading into the communications room is unsafe. Exposed dead end and electrical wiring inside communications room is unsafe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Electrical wiring running through the door removed. Wiring in the communications room clean up.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 19 September 2006
Resolved
Load Lines and Deck Lines not painted in white or yellow on a dark background or in black on a light background.
Due 21 September 2006
Resolved 21 September 2006
Resolution: Load Line painted.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 19 September 2006
Resolved
All hydrostatic release units on liferafts installed improperly.
Condition: Improper Installation
Due 21 September 2006
Resolved 21 September 2006
Resolution: Hydrostatic release units fixed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 September 2006
Resolved
Oily Water Separator is inoperable. Bilge pump is inoperable. Must fix prior to departure to the satisfaction of the attending Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Oily Water Seperator bilge suction pump replaced.
Engineering › Gasoline Engine (auxiliary) › Hose, Cooling System (4 cycle)
Issued 19 September 2006
Resolved
Cool water pump missing on the No. 1 generator. Unable to supply cooling water to the generator rendering it inoperable. Must fix prior to departure to the satisfaction of the attending Class Surveyor. 46CFR111.10-4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Cool water pump replaced.
Operations/Management › Pollution › Control of Garbage
Issued 19 September 2006
Resolved
Witnessed crew discharging ground up food into intercostals waterway. Crew was informed of environmental regulations regarding garbage and chose to ignore instructions. Must rectify deficiency prior to departure to the satisfaction of the U.S. Coast Guard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Crew was given MARPOL Annex V training.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 19 September 2006
Resolved
Containment missing under Fuel Oil Fill Pipe located on the port side aft of the superstructure and at the aft fuel station under the crane between the anchor winches. Rectify deficiency prior to departure to the satisfaction of the attending Call Surveyor.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Class Surveyor did not require containment under international regulations. Coast Guard requires the barge to have at least 3 portable containments equaling 1/2 a barrel of containment while fueling in the United States.
Lifesaving › Inflatable Liferafts › Float Free
Issued 19 September 2006
Resolved
Aft starboard liferaft gripe strap is missing. Strap has been replace by a small yellow line.
Condition: Improper/Lack of Maintenance
Due 21 September 2006
Resolved 21 September 2006
Resolution: Liferaft gripe found and yellow line replaced.
Operations/Management › Drills/Instruction › Fire
Issued 19 September 2006
Resolved
Failed fire drill on 20SEP06 due to crew incompetence. Failed fire drill on 20SEP06. Crews reaction time improved but lack of communications and knowledge of fire fighting equipment is substandard. Rectify deficiency prior to departure from port to the satisfaction of the attending Class Surveyor. *SEE FORM B ATTACHMENT FOR MORE INFO
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Flag State Surveyor provided information to the vessel. Vessel was given training. Key crew members sent to firefighting school.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 September 2006
Resolved
No records for fire fighting and abandon ship drills available for inspection.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: Crew was given training on logs.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 September 2006
Resolved
General Housekeeping and safety requirements for slips, trips, falls, accident prevention and fire prevention is substandard. Rectify deficiency prior to departing port to the satisfaction of the U.S. Coast Guard. *SEE FORM B ATTACHMENT FOR MORE INFORMATION.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Crew cleaned spaced and rectified identified deficiencies.
Construction/Loadline › Structures › Manhole
Issued 19 September 2006
Resolved
Wooden cover over open void in the laundry room. No documentation illustrating approved alterations. ICLL 1966 Article 10
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Wooden cover removed. Metal hatch found underneath the wood. Wood was put in place to prevent a tripping hazard making the wood and deck flush together.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 19 September 2006
Resolved
Water heater suppling hospital in the dive storage locker is inoperable. No heating or hot water supplies are available in the hospital.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: Barge recieved parts to fix the water heater.
Engineering › Bilge Water Management System › Not Operational
Issued 19 September 2006
Resolved
Excessive oily water in the bilges. 18 inches of oily water located in bilges. Rectify deficiency prior to departure from port to the satisfaction of the U.S. Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Bilges pumped dry.