EMILEE is a 1979 industrial vessel. The Coast Guard has recorded 14 inspections since 2006, most recently in February 2022, along with 20 deficiencies.

Records from 2006 to 2022. Most recent: inspection, 2 February 2022.

Built
1979
Last inspected
2 February 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 2 February 2022
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2006–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8935653
HP9346
856119
Flag
PANAMA
Maury page id
psix-856119

Documentation record

Tonnage as PSIX records it3089 - Convention (Subpart B), Gross Ton
2542 - Convention (Subpart B), Net Ton
5890 - Displacement, Ton
3089 - Regulatory (Subpart C or D), Gross Ton
2542 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAGNUM Passenger (Inspected) · MISLE 419649 · 28 February 2019 · activity 6637492O'ROURKE TIDE Offshore Supply Vessel · MISLE 1325368 · 28 February 2019 · activity 6637492CINDY TIDE Offshore Supply Vessel · MISLE 1379110 · 28 February 2019 · activity 6637492GAMMAGE TIDE Offshore Supply Vessel · MISLE 1426694 · 28 February 2019 · activity 6637492

Inspection history · 14

2 February 2022 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7389528
28 February 2019 Loadline Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6634451
28 February 2019 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6637492
8 February 2018 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6352106
6 July 2016 MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5932023
8 April 2016 MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5857524
16 April 2015 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5107285
9 January 2015 NPV Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5052115
30 December 2013 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4787222
12 December 2011 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4206368
7 December 2010 ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3892269
25 September 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2786409
21 September 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2784792
19 September 2006 MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2780170

Deficiency record · 20

Documentation › Logs/Records › Garbage Recordkeeping
Issued 30 December 2013 Resolved
0190 - Ship's logbooks/compulsory entries - Every ship of 400 Gross Tons and above shall be provided with a garbage record book that is in the form specified in the Appendix to Annex V of MARPOL. Ship's garbage record book did not have correct format. Garbage receipts were not maintained IAW Appendix of Annex V. MARPOL Annex V/10.3
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2015
Resolution: Proper documentation provided.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 30 December 2013 Resolved
0190 - Ship's logbooks/compulsory entries - Each entry in the Garbage Record Book shall be made and signed on the date of discharge. Garbage Record Book entries were not made on the date of discharge. MARPOL Annex V/10.3.1
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2015
Resolution: Proper documentation provided.
Operations/Management › Pollution › Control of Garbage
Issued 19 September 2006 Resolved
No Garbage Management Plan located on board. No Garbage Management Placards onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 25 September 2006
Resolution: Garbage Management Plan and Placarding placed on board the barge.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 19 September 2006 Resolved
Garbage Record Book not being maintained properly. No signatures for discharge entries or Master/Foreman signature at the bottom of the page. GRB starts on page 7. Pages 1-6 of the GRB have been torn out. No garbage receipts on board. Marine Inspectors were informed the GRB was place on board 17SEP06 and the first recorded log entry started on 13APR06. See attached copies of the C/B ANNA 4's GRB
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Training provided to crew on how to maintain the Garbage Record Book.
Documentation › Logs/Records › Oil Record Book
Issued 19 September 2006 Resolved
Oil Record Book not being maintained properly. Long periods of time unaccounted for. Signatures missing for individual operations on pages 1 and 2. Master/Forman signature missing at the bottom of pages 1 and 2. Page 4 of the Oil Record Book is missing. See attached copies of the C/B ANNA 4's Oil Record Book.
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Training provided to crew on maintenance of the Oil Record Book.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 19 September 2006 Resolved
No oil discharge placards onboard.
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Discharge Of Oil Placarding placed onboard in proper locations.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 19 September 2006 Resolved
Electrical wiring running through a hole in the base of the door leading into the communications room is unsafe. Exposed dead end and electrical wiring inside communications room is unsafe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Electrical wiring running through the door removed. Wiring in the communications room clean up.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 19 September 2006 Resolved
Load Lines and Deck Lines not painted in white or yellow on a dark background or in black on a light background.
Due 21 September 2006
Resolved 21 September 2006
Resolution: Load Line painted.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 19 September 2006 Resolved
All hydrostatic release units on liferafts installed improperly.
Condition: Improper Installation
Due 21 September 2006
Resolved 21 September 2006
Resolution: Hydrostatic release units fixed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 September 2006 Resolved
Oily Water Separator is inoperable. Bilge pump is inoperable. Must fix prior to departure to the satisfaction of the attending Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Oily Water Seperator bilge suction pump replaced.
Engineering › Gasoline Engine (auxiliary) › Hose, Cooling System (4 cycle)
Issued 19 September 2006 Resolved
Cool water pump missing on the No. 1 generator. Unable to supply cooling water to the generator rendering it inoperable. Must fix prior to departure to the satisfaction of the attending Class Surveyor. 46CFR111.10-4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Cool water pump replaced.
Operations/Management › Pollution › Control of Garbage
Issued 19 September 2006 Resolved
Witnessed crew discharging ground up food into intercostals waterway. Crew was informed of environmental regulations regarding garbage and chose to ignore instructions. Must rectify deficiency prior to departure to the satisfaction of the U.S. Coast Guard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Crew was given MARPOL Annex V training.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 19 September 2006 Resolved
Containment missing under Fuel Oil Fill Pipe located on the port side aft of the superstructure and at the aft fuel station under the crane between the anchor winches. Rectify deficiency prior to departure to the satisfaction of the attending Call Surveyor.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Class Surveyor did not require containment under international regulations. Coast Guard requires the barge to have at least 3 portable containments equaling 1/2 a barrel of containment while fueling in the United States.
Lifesaving › Inflatable Liferafts › Float Free
Issued 19 September 2006 Resolved
Aft starboard liferaft gripe strap is missing. Strap has been replace by a small yellow line.
Condition: Improper/Lack of Maintenance
Due 21 September 2006
Resolved 21 September 2006
Resolution: Liferaft gripe found and yellow line replaced.
Operations/Management › Drills/Instruction › Fire
Issued 19 September 2006 Resolved
Failed fire drill on 20SEP06 due to crew incompetence. Failed fire drill on 20SEP06. Crews reaction time improved but lack of communications and knowledge of fire fighting equipment is substandard. Rectify deficiency prior to departure from port to the satisfaction of the attending Class Surveyor. *SEE FORM B ATTACHMENT FOR MORE INFO
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Flag State Surveyor provided information to the vessel. Vessel was given training. Key crew members sent to firefighting school.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 September 2006 Resolved
No records for fire fighting and abandon ship drills available for inspection.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: Crew was given training on logs.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 September 2006 Resolved
General Housekeeping and safety requirements for slips, trips, falls, accident prevention and fire prevention is substandard. Rectify deficiency prior to departing port to the satisfaction of the U.S. Coast Guard. *SEE FORM B ATTACHMENT FOR MORE INFORMATION.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Crew cleaned spaced and rectified identified deficiencies.
Construction/Loadline › Structures › Manhole
Issued 19 September 2006 Resolved
Wooden cover over open void in the laundry room. No documentation illustrating approved alterations. ICLL 1966 Article 10
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2006
Resolved 25 September 2006
Resolution: Wooden cover removed. Metal hatch found underneath the wood. Wood was put in place to prevent a tripping hazard making the wood and deck flush together.
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 19 September 2006 Resolved
Water heater suppling hospital in the dive storage locker is inoperable. No heating or hot water supplies are available in the hospital.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: Barge recieved parts to fix the water heater.
Engineering › Bilge Water Management System › Not Operational
Issued 19 September 2006 Resolved
Excessive oily water in the bilges. 18 inches of oily water located in bilges. Rectify deficiency prior to departure from port to the satisfaction of the U.S. Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2006
Resolution: Bilges pumped dry.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.