Records from 2006 to 2026. Most recent: inspection, 13 May 2026.
Inspection history · 46
13 May 2026
Administrative Inspection · Deficiency Check · Vessel Attendance
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8371610
7 May 2026
Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8368807
29 January 2026
Drydock Extension
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8309361
16 January 2026
Drydock Extension
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8297538
5 August 2025
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8200169
4 November 2024
MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8022775
12 October 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7807528
14 July 2023
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7758105
26 October 2022
In-Service Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7585924
22 June 2022
Construction Oversight · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7484138
28 March 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7419962
21 October 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7337124
5 October 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7326993
2 August 2021
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7258295
5 March 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7150738
17 February 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7141922
21 October 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6838952
15 August 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6784790
8 March 2019
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6637047
12 February 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6625484
3 October 2018
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6560109
30 September 2018
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6553032
13 August 2018
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6511218
15 June 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6445068
25 May 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6428298
5 March 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6365797
7 February 2018
MARPOL Annex I Examination · MTSA Verification · Annual Inspection · MARPOL Annex IV Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6351317
5 December 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6318907
28 October 2016
Cargo Tank Internal · Administrative Inspection · COI Inspection · Internal Structural Exam · Drydock Exam · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6031376
9 October 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6021538
18 March 2016
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5835790
5 December 2014
Internal Structural Exam · Periodic Inspection · MARPOL Annex VI Survey · Drydock Exam · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5034613
11 August 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4955439
31 March 2014
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4825913
4 March 2014
MTSA/ISPS Verification · MARPOL Annex V Examination · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4809940
4 June 2012
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4333915
13 December 2011
Internal Structural Exam · MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex I Examination · COI Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4206996
21 June 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4052228
30 December 2010
MTSA Verification · MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3917945
9 March 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3430208
24 January 2008
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3135357
21 May 2007
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2936095
21 May 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2936136
22 February 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2876355
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806562
11 October 2006
Cargo Tank Internal · MTSA Verification · Construction Oversight · Internal Structural Exam · COI Inspection · Administrative Inspection · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2798341
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 November 2024
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station. Could not test #1 shut down due to inability to start prime mover. Demonstrate operation and remote shutdown prior to cargo operations. 46CFR 32.50-35(a).
Action required: 705 - Other - as specified
Resolved 14 November 2024
Resolution: Reviewed video evidence of cargo pump prime mover emergency shutdown.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 November 2024
Resolved
Each cargo tank of a tank ship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm. The high-level alarm must activate an alarm once the cargo level reaches 95 percent of the tank capacity or higher, but before the tank overfill alarm. High level alarm on #1 Port Cargo tank was inoperative. Demonstrate operation prior to cargo operations in #1 port cargo tank. 46CFR 39.2007(a),(c)
Action required: 705 - Other - as specified
Resolved 14 November 2024
Resolution: Reviewed video of proper operation of high level alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 November 2024
Resolved
Where pressure-indicating gages are used, the upper range of the gage shall not be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Gauge range was outside of parameters, replace with appropriate gauge. 46CFR 54.15-5(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2024
Resolution: Reviewed photograph of new gauge installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 November 2024
Resolved
The spring in a relief valve in service for pressures up to and including 250 pounds per square inch must not be reset for any pressure more than 10 percent above or 10 percent below that for which the relief valve is marked. Relief valve did not reset within the required parameters. Demonstrate proper reset during operation of pressure relief valve. 46CFR 54.15-10(g).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2024
Resolution: Reviewed photograph of new pressure relief valve installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 November 2024
Resolved
Electric installations on vessels must ensure maintenance of services necessary for safety under normal and emergency conditions, protection of passengers, crew, other persons, and the vessel from electrical hazards, and maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved. Generator missing interlock protection between barge and shore power. Install prior to operation of generator. 46CFR 111.01(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2024
Resolution: Reviewed photograph of new interlock installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 November 2024
Resolved
Piping systems conveying vapors, gases, or mixtures whose temperature exceeds 150 °F must be suitably insulated as necessary to preclude injury to personnel. Lagging on #1 and #2 Cargo pump prime movers missing. Replace prior to operations of #1 and #2 cargo pumps. 46CFR 56.50-1(k)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2024
Resolution: Reviewed photgraph of newlt installed lagging.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 November 2024
Resolved
Each tank vessel must meet the applicable requirements in sub-chapter S of this chapter as applicable to vessels with watertight doors in bulkheads that have been made watertight to comply with flooding or damage stability regulations. Watertight doors in starboard side accommodation were not properly sealing. Adjust doors to ensure proper closure/seal. 46CFR 31.10-30, 46CFR 170.248(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2024
Resolution: Observed tightened doors.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 November 2024
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. To maintain a valid Certificate of Inspection, you must complete your annual inspection within the period specified in § 31.10-17 (a) and (b) and your Certificate of Inspection must be endorsed. Vessel did not complete its annual inspection within the required time frame. Complete annual inspection prior to vessel movement.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 November 2024
Resolution: Conducted Annual Inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 12 October 2023
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the vessels to the satisfaction of the assigning authority. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. Attending Marine Inspector (MI) found load lines not properly painted with contrasting color. Enact permanent repairs to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 24 October 2023
Resolution: Received documenatation clearing deficiency.
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 12 October 2023
Resolved
The vessel's name or number shall be so displayed at the highest part of the vessel's hull or permanent structure that the name or number can be seen from either side.
MI found the vessels name and official number missing from port side of vessel. Enact permanent repairs to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 25 October 2023
Resolution: Vessel Name was properly marked on the bow.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 October 2023
Resolved
Each hose must be marked with one of the following: For oil products, the words "OIL SERVICE". MI found fuel and cargo hoses onboard not marked with the words "OIL SERVICE". Enact permanent repairs to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 16 October 2023
Resolution: Photos received of OIL SERVICE ONLY Marking on hoses.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 12 October 2023
Resolved
Each hose also must be marked with the following, except that the information required by paragraphs (f)(2) and (3) of this section need not be marked on the hose if it is recorded in the hose records of the vessel or facility, and the hose is marked to identify it with that information: (1) Maximum allowable working pressure; (2) Date of manufacture; and (3) Date of the latest test required by 33 CFR 156.170. MI found the fuel and cargo transfer hoses onboard do not have the proper markings as required. Enact permanent repairs to the satisfaction of the attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2023
Resolved 16 October 2023
Resolution: Markings were corrected.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 14 December 2022
Resolved
The vessels cargo temperature gauging system is broken/missing probes/has exposed wires. This system shall not be used until it is fixed or replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 24 January 2023
Resolution: Received pics from vessel rep that the cargo temp gauging system has been removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 October 2022
Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met.
All required documentation required to be submitted to the cognizant OCMI as stated in CG MSC Letter serial#C1-2202232 dated July 7, 2022 must be submitted for review.
Barge is not permitted to conduct any work affecting the safety of the vessel and its load line until all the comments addressed in the mentioned letter above, a repair plan to include proof diver operation is conducted in accordance with 46 CFR Part 197, and information on the cofferdam installation is submitted to cognizant OCMI and written approval is received.
Action required: 705 - Other - as specified
Resolved 29 October 2022
Resolution: MI attended, UT/MT/Dive reports and Class statement received, see docs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 June 2022
Resolved
Replace all battery cable installations labeled "for welding use" with the proper battery cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 24 January 2023
Resolution: Received pcs from vessel rep illustrating the battery cables were replaced with proper cables
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 October 2021
Resolved
The terms, endorsements and conditions set forth on a certificate of inspection shall have the same force and effect as the regulations contained in this subchapter. Prior to loading cargo, contact the nearest CG unit to obtain an amended COI with the updated operator and associated operator controlled documents and procedures.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2021
Resolution: Recieved updated certificates reflecting new operator, amended COI.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 August 2021
Resolved
The following locations in the weather area are class 1 division 1: within 5 meters (16ft) of cargo pressure/vacuum valves with an unlimited height.
Barge has multiple deck lights rated as class 1 division 2 within 16 feet of pressure/vacuum valves.
46 CFR 111.105-31(l)(3). 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2021
Resolved 21 December 2021
Resolution: The class 1 division 2 lights were removed and 08 Class 1 division 1 explosion proof lights were installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 2 August 2021
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm.
HL/OF alarms are currently seized. Provide proof of functionality upon first loading of cargo for all alarms
Action required: 705 - Other - as specified
Resolved 21 December 2021
Resolution: Conducted an operational test of all 16 cargo tank alarms, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 April 2021
Resolved
Vessel must be built to a strength standard (ABS) or other recognized classification society as per the regulation and maintained to ensure safe service. Vessel was built to ABS standard during a NVIC 10-82 project. Deck plating comprises a highly stress portion of the hull girder and is critical to the longitudinal strength of the vessel. During the recent DRY-DOCK inspection massive pitting was found through the entire deck and subsequent UT testing report shows extensive wastage over allowable limits throughout the entire deck. Must submit a repair/replacement plan to Sector New York inspections and Classification Society for review/approval prior to work commencing.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 29 April 2021
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 October 2019
Resolved
All installations shall be of marine type engines suitable for the intended service. Marine Inspectors witnessed #2SSDG with fuel leaks from #5 fuel injector. Repair to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2019
Resolution: Received ABS Class report attesting to satisfactory repairs/operation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 October 2019
Resolved
All installations shall be of marine type engines suitable for the intended service. Marine Inspectors witnessed excessive soot build up on #1SSDG turbo charger and lagging causing potential fire hazard. Vessel to rectify deficiency to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2019
Resolved 6 August 2021
Resolution: Received ABS Class report attesting to satisfactory repairs/operation.
Verified rectification on 06AUG21, Act. No. 7258295.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 21 October 2019
Resolved
Exhaust system shall meet the requirements of 46CFR58.10-5(d) and ABYC P-1 ; shall be designed and installed to prevent the ingress of water from entering the exhaust system under normal operating conditions. Marine Inspectors observed three individual exhaust mufflers, each with approximate 6-inch diameter holes. Repair to original design prior to utilizing installed cargo pumps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2019
Resolution: Received ABS Class report attesting to satisfactory replacement of all three exhaust mufflers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 August 2019
Resolved
Each junction box must be suitable for the environment in which it is installed. Wire gland on the starboard running light was loose and did not provide a watertight connection. Cable entrance to the running light must be made watertight.
46 CFR 111.81-1(f)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 August 2019
Resolution: Company hired third party electrical contractor to replace stbd & port glands. USCG inspector witnessed completed repair and brightly burning running lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 15 August 2019
Resolved
The person in charge of a vessel shall be responsible for monitoring the security and integrity of the tank barge and for ensuring adherence to proper safety precautions. These responsibilities include, but are not limited to -
(i) Ensuring that any tank barge added to the tow has all tank openings properly secured; has its freeing-port
and scuppers, if any, unobstructed; meets any loadline or freeboard requirements; and neither leaks cargo into
the tanks, voids, or cofferdams. Port forward void hatch
gasket was leaking. The lip of the hatch appeared to be in questionable condition. Replace watertight gasket in forward port cargo hatch.
46 CFR 35.05-15(a)(i)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 August 2019
Resolution: Tankerman replaced worn gasker with new. USCG Inspector visually inspected installation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2019
Resolved
All electrical installations in hazardous locations must comply must comply with the general requirements of section 33 of IEEE 45-1998. Numerous Tank Level Indicators on the cargo deck has significant oxidized and cracking fittings at the cable entrances.
Replace wasted wiring runs to electronic tank level monitoring devices throughout barge as original.
46 CFR 111.105-3
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2019
Resolved 6 August 2021
Resolution: Verified rectification on 06AUG21, Act. No. 7258295.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 15 August 2019
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that is at least 1/2 inch diameter and is at least 1 inch long. Stud on the starboard side was approximately 40% wasted and flange face showed signification oxidation potentially prevented a liquid tight connection. Prior to transferring any 46 CFR Subchapter D flammable and/or combustible cargoes in accordance with vessel's Cargo Authority Attachment that collect vapors, ensure vapor collection systems meets requirements to the satisfaction of the attending U.S. Coast Guard marine inspector.
46 CFR 39.2001
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2021
Resolution: Verified rectification on 06AUG21, Act. No. 7258295.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 August 2019
Resolved
All tank vessels, the construction or conversion of which is started on or after July 1, 1951, shall conform to the requirements in this subpart in construction of hulls. The hull and deckhouses shall be of steel or iron construction except that the pilothouse and decks over quarters may be constructed of wood. Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. Numerous areas on the forward cargo deck appear to have excessive pitting approximately 3 inch in diameter. These areas must be gaged to determine extent of wastage and report provided to Sector NOLA. These ares shall be considered for replacement during next yard period.
46 CFR 32.60-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2019
Resolved 29 October 2021
Resolution: Resolved during 2021 dry dock period.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2019
Resolved
At each inspection for certification the marine inspector shall conduct such test and inspections of the auxiliary machinery and of its associated equipment as he feels necessary to check safe operation. Prior to the inspection, the marine inspector notified the company that high jacket water temperature, and over-speed trips be tested on each auxiliary engine among other test, however these test were not preformed during the inspection. Provide a technician's report certifying proper operation of high jacket water temperature and over-speed trips on each auxiliary engine. 46CFR31.10-17(a)(2)
46CFR61.20-3(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2019
Resolved 21 March 2019
Resolution: Received technician report from Marine Systems, INC in Houma, LA certifying proper set pressures for overspeed, high coolant temp, and low oil pressure on each diesel generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2019
Resolved
In general, connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. The battery terminal ends of each starting battery cables for all 4 generators and two cargo pumps were corroded and secured with wing nuts, not allowing for a secure connection. Replace all terminal ends to each generator and cargo pumps with suitable terminal connections and captive securing devices that will not back out with vibrations. 46CFR31.35-1
46CFR111.30-17
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2019
Resolved 27 March 2019
Resolution: Vessel replaced the terminals for each starting battery set and placed double locking nuts on the terminal connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 March 2019
Resolved
All installations shall be of marine type engines suitable for the intended service. The #2 diesel generator was leaking coolant during the inspection. The leak was corrected prior to departure of the Marine Inspector. 46CFR31.30-1
46CFR58.10-10(a)
46CFR58.10-5(a)
Action required: 10 - Deficiency Rectified
Due 8 March 2019
Resolved 8 March 2019
Resolution: On board technician corrected deficiency prior to departure of the Marine Inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 August 2018
Resolved
Company failed to notify the Coast Guard of three (03) Service generator diesel prime movers replacements.
Action required: 10 - Deficiency Rectified
Due 14 August 2018
Resolved 14 August 2018
Resolution: CG notified.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Diesel engine relating to air pollution control
Issued 14 August 2018
Resolved
International Air Pollution Certificate is invalid. Company failed to have IAPP survey completed on newly installed service generator prime movers (03). Vessel restricted from sailing foreign until new IAPP survey is completed and IAPP Certificate is issued.
MARPOL VI/5.1.5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 8 March 2019
Resolution: Verified installed diesel prime movers for the generators were under 130kw and therfore not required to be listed on the IAPP.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 August 2018
Resolved
Company failed to notify the Coast Guard of newly installed MSD/Grey Water tank and piping arrangement.
Action required: 10 - Deficiency Rectified
Due 14 August 2018
Resolved 14 August 2018
Resolution: CG Notified
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 13 August 2018
Resolved
Prior to departure from anchorage. Renew worn hydraulic hoses and leaking valve at forward mooring winch to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2018
Resolved 14 August 2018
Resolution: Accepted ABS Class report of attendance. Hoses renewed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 13 August 2018
Resolved
Prior to departure from New Orleans, have high level overfill devices serviced. High level/overfill device for #2 STBD C/T did not function as manufacturer intended. Troubleshoot and affect repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2018
Resolved 14 August 2018
Resolution: Accepted ABS Class report of attendance. Bergen tech rep attended and serviced the entire system. #2 stbd C/T functioning as designed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 August 2018
Resolved
Prior to departure from New Orleans, finalize troubleshooting procedures and affect repairs to the aft Thermal Fluid Heater. Provide all technician’s reports from attendance in Port of New Orleans AUG2018. Affect repairs to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2018
Resolved 14 August 2018
Resolution: Accepted ABS Class report of attendance. Technical represenatative attended, affected repairs, system functioning as designed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 13 August 2018
Resolved
Prior to departure from New Orleans, troubleshoot and affect repairs to the Electronic tank level indicating device (Bergen System). Affect repairs to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2018
Resolved 14 August 2018
Resolution: Accepted ABS Class report of attendance. Bergen tech rep attended and serviced the entire system. Electronic ullage system functioning as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2018
Resolved
Prior to departure from New Orleans, renew leaking fittings, hoses, & piping arrangements on both cranes to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2018
Resolved 14 August 2018
Resolution: ABS attended, Hoses replaced, operational test conducted. Cranes functioned as designed with no leaks.
Deck/Cargo › Cargo Heating › General
Issued 25 May 2018
Resolved
Remove "jumpers" on Low Fuel Oil PR for aft Thermal Fluid Heater(TFH). Provide technicians report to attending USCG Marine Inspector attesting to the operational readiness of the TFH, and conduct testing of the TFH in the presence and to the satisfaction of USCG Marine Inspector prior to next use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Verified jumper removed and full operational test of boiler.
Electrical › Electric Generation Source (service) › Generator
Issued 25 May 2018
Resolved
Re-install Lockout bar on generator switchboard to ensure generators will not be simultaneously used due to lack of syncroscope or ability to parallel in accordance with 46 CFR 111.30-25(d). To the satisfaction of a USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2018
Resolved 15 June 2018
Resolution: Reinstalled lockout bar.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 May 2018
Resolved
Repair two deck lights on outboard side of Crew House. Drain water and prove intrinsically safe to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: New cable was installed between both lights and enclosures made intrinsically safe.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 May 2018
Resolved
Remove "Oil" soaked lagging from TFH space and complete floor cleaning to decrease fire hazard and slip, trip, fall safety to the satisfaction of a USCG Marine Inspector.
Due 29 May 2018
Resolved 29 May 2018
Resolution: Rectified on the spot to the satisfaction of the USCG MI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 May 2018
Resolved
Repair Deck Eye Wash/Shower to as designed condition to the satisfaction of USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Piping repaired to deck eyewash station, operational test performed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 7 February 2018
Resolved
The bellow covers on all three cargo pumps are not vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 5 March 2018
Resolution: Received report from vessel rep clearing def.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 7 February 2018
Resolved
Flame screen on port vent for the sewage tank has excessive build up of residue.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 15 February 2018
Resolution: Attending Marine Inspector witnessed the vessel's crew correcting the def on the spot by replacing the flame screen.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 5 December 2017
Resolved
Found in the Thermal Fluid Htr room, ASH Monitor System shows code "F4" Sensor Leads open or Shorted. Repair or Provide Tech report to testify as to thecriticalness of component to system operation and / or safety of the thermal fluid htr system prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2017
Resolved 6 December 2017
Resolution: Vessel rep had two marine electricians from Lyon’s shipyard to evaluate the ASH Monitor system, after trouble shooting and an operational test of the system it was found to be not attached to the operational control of the fluid thermal fluid heater.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 December 2017
Resolved
Found in Tankermans house, Beacon 200 gas monitoring system was inop. Provide proof of proper operation of gas monitoring system. (Prior to crew sleeping onboard)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 6 December 2017
Resolution: Vessel rep calibrated the system and ran a operational test and passed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 November 2016
Resolved
See worklist, several ballast tank hatches and combings are wasted, must renew as appropriate prior to credit ddx.
Action required: 705 - Other - as specified
Resolved 14 December 2016
Resolution: MI verified worklist items, all satisfactory.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 March 2014
Resolved
Service fire screen door to crew accommodations to ensure proper self closing.
Due 4 April 2014
Resolved 31 March 2014
Resolution: replace door
Electrical › Lighting (service) › Lighting Fixture
Issued 4 March 2014
Resolved
Replace light guard in crew accommodations and properly mount 02 exterior lights IWO deck fuel tank.
Due 4 April 2014
Resolved 31 March 2014
Resolution: Replaced cover on light
Electrical › Electric Supply System (service) › Cable
Issued 4 March 2014
Resolved
Hardwire L.E.L. sensor in crew accommodations.
Due 4 April 2014
Resolved 7 March 2014
Engineering › Pressure Vessel › Relief Valve
Issued 4 March 2014
Resolved
Replace relief valve on air receiver IWO generator room.
Due 4 April 2014
Resolved 31 March 2014
Resolution: Replace safety valve on pressure vessel
Construction/Loadline › Hull › Bottom Plating
Issued 13 December 2011
Resolved
Hull plate portside bottom damaged by cutting of staging just aft of ballast outtake. C/R with insert.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 January 2012
Resolved 22 December 2011
Resolution: Received class report stating the repair was made to the satisfaction of class.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 13 December 2011
Resolved
Provide a copy of a valid ILLC prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2011
Resolution: Received a copy of the current ILLC.
Electrical › Electric Generation Source (service) › Generator
Issued 13 December 2011
Resolved
Demonstrate the low lube oil pressure shut downs on all generators fuction properly. 46 CFR 111.12-1c.
Action required: 705 - Other - as specified
Due 24 January 2012
Resolved 4 June 2012
Resolution: Received copy of tech report installing low lube shutdowns and testing IAW w/specs. Tech company: Marine Systems Inc.
Documentation › Logs/Records › Oil Record Book
Issued 30 December 2010
Resolved
Last 3 years of oil record books not on board. Oil record book for machinery not onboard or utilized. Provide oil record book for machinery.
Due 6 January 2011
Resolved 30 December 2010
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 May 2007
Resolved
C/R #4 & 5 SSL in aft bay of #7 stbd DB tank.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 8 June 2007
Resolution: Received copy of ABS report attesting to the satisfactory repairs to side shell plating and internal structures IWO of No. 7 stbd ballast tank.
Construction/Loadline › Hull › Stiffener
Issued 21 May 2007
Resolved
C/R #4 & 5 transverse stiffener IWO swash bulkhead in #7 stbd DB tank.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 8 June 2007
Resolution: Received copy of ABS report attesting to the satisfactory repairs to side shell plating and internal structures IWO of No. 7 stbd ballast tank.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 May 2007
Resolved
C/R swash bulkhead IWO #4 & 5 transverse stiffener.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 8 June 2007
Resolution: Received copy of ABS report attesting to the satisfactory repairs to side shell plating and internal structures IWO of No. 7 stbd ballast tank.
Construction/Loadline › Hull › Side Shell
Issued 21 May 2007
Resolved
C/R SS plating btwn #3 & 6 SSL.
Action required: 705 - Other - as specified
Due 20 June 2007
Resolved 8 June 2007
Resolution: Received copy of ABS report attesting to the satisfactory repairs to side shell plating and internal structures IWO of No. 7 stbd ballast tank.
Construction/Loadline › Hull › Side Shell
Issued 21 May 2007
Resolved
Provide proof of satisfactory air test for # 7 stbd DBT or provide class report from ABS stating vessel's fit for service prior to cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2007
Resolution: Received copy of ABS report. Tank tested satisfactory and vessel found fit for service.