Records from 2009 to 2026. Most recent: inspection, 3 February 2026.
Documentation record
Registered dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
Registered tonnagegross 11,147 / net 11,147
ITC dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
ITC tonnagegross 13,462 / net 8,791
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2009
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13462 - Convention (Subpart B), Gross Ton
11147 - Regulatory (Subpart C or D), Gross Ton
8791 - Convention (Subpart B), Net Ton
27023 - Dead Weight, Ton
11147 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
3 February 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8306155
8 July 2025
Annual Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8174092
14 August 2024
Cargo Tank Internal · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7959938
23 January 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7853358
12 June 2023
MARPOL Annex I Examination · Annual Inspection · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7841815
22 February 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7647288
20 September 2022
Administrative Inspection · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7562765
11 March 2022
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7414404
28 February 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7403399
30 September 2021
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7323945
30 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7272685
12 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7253688
14 October 2020
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7082495
1 November 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6847349
29 June 2019
MTSA/ISPS Verification · Drydock Exam · Internal Structural Exam · Administrative Inspection · Damage Survey · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6744663
4 December 2018
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6596545
14 August 2018
MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6512049
2 August 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6503786
6 November 2017
MTSA/ISPS Verification · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6304725
27 April 2017
Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6133734
14 October 2016
MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6024233
12 August 2015
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5215252
4 June 2015
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5143991
21 May 2015
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5131090
4 November 2014
Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5012807
22 September 2014
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4989212
13 August 2014
MARPOL Annex I Examination · MARPOL Annex VI Survey · Hull Examination · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4931816
26 August 2013
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4698034
2 November 2012
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4475154
19 October 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4467634
5 September 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4432994
9 May 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4312546
26 April 2012
Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4295839
17 October 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4171399
15 October 2010
MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3865989
31 March 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3712102
24 July 2009
MARPOL Annex VI Survey · Initial Certification · Ballast Water Examination · MTSA/ISPS Verification · Construction Oversight · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3544478
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 September 2022
Resolved
If the prime mover is a diesel engine, there must be an audible alarm that sounds on low oil pressure and high cooling water temperature. Starboard generator failed to alarm when testing high cooling water. Sensor was replaced and tested satisfactorily.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 September 2022
Resolved 20 September 2022
Resolution: Sensor replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 September 2021
Resolved
Each cable installation must meet section 25 of IEEE (incorporated by reference). USCG marine inspector (MI) observed in excess of 80% of cable way hangers and trays on deck severely wasted due to corrosion. Vessel is to identify and replace the worst areas with all available material prior to departure to the satisfaction of USCG MI. Provide repair plan to replace remaining cable ways upon arrival of remaining material. Include in the plan estimated time of arrival for remaining materials, estimated time for replacement and completion date of project.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2021
Resolved 5 October 2021
Resolution: Vessel provided photographic evidence attesting to replacement of all deck cableway hangers.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 31 October 2014
Resolved
Submit plans to USCG MSU Portland, Oregon for the installation/designation of a sludge tank required by MARPOL Annex I Regulation 12. If a fixed sludge tank is proposed, than the requirements of MARPOL Annex I Reg 13 apply. As an alternative to a fixed sludge tank, an approved MPT can be used. If MPT is offloaded before pumping, than Reg 13 does not apply. 46 CFR 30.01-10 and 46 CFR 64.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 January 2015
Resolved 4 June 2015
Resolution: Operator intends to use retention tanks installed during construction.