MAURY USCG vessel records
← All vessels

PRIDE

Built
2009
Last inspected
8 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 8 July 2025
…with no type recorded21
Operational controls None recorded without a removal date
Years with a record 17 calendar years (2009–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9369423
WDE9046
870754
Flag
UNITED STATES
Maury page id
psix-870754

Documentation record

Registered dimensions (L × B × D)129.6 ft × 42.0 ft × 21.9 ft
Registered tonnagegross 465 / net 316
ITC dimensions (L × B × D)129.6 ft × 42.0 ft × 21.9 ft
ITC tonnagegross 1,052 / net 315
BuilderVT HALTER MARINE INC · ESCATAWPA, MS, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 18 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1052 - Convention (Subpart B), Gross Ton
465 - Regulatory (Subpart C or D), Gross Ton
315 - Convention (Subpart B), Net Ton
786 - Dead Weight, Ton
316 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 71 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

650-7 Tank Barge · MISLE 862266 · 2 August 2018 · activity 6503786650-7 Tank Barge · MISLE 862266 · 31 March 2010 · activity 3712102

Inspection history · 71

8 July 2025 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8174080
25 November 2024 Permit to Proceed
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8040494
18 October 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8021165
18 October 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8022431
27 September 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8010195
20 August 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7985111
20 August 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7997187
14 August 2024 COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7976408
1 November 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7818609
27 June 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7725343
12 June 2023 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7713992
16 September 2022 Annual Inspection · Deficiency Check · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7564657
24 March 2022 Examination of Repairs · ACP Drydock Oversight · Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7418709
28 February 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7403461
13 January 2022 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7382114
30 September 2021 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7323922
14 October 2020 ACP Annual Oversight · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7077358
29 May 2019 Drydock Exam · Administrative Inspection · ACP Handover Survey · Internal Structural Exam · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6744659
31 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6571900
3 October 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6553727
20 August 2018 Type not recorded
No type recorded · USCGC SAILFISH (WPB 87356) · USCG Northeast District (CGD-NE) · Activity 6520814
14 August 2018 MTSA/ISPS Verification · MARPOL Annex IV Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6512739
2 August 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6503786
6 November 2017 MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6304718
12 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6265488
12 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6123034
14 October 2016 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6024291
18 April 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5856360
17 April 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5858035
17 April 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5858070
3 February 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5809330
27 December 2015 Examination of Repairs · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5788022
27 December 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5792925
11 August 2015 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5205218
13 August 2014 Internal Structural Exam · COI Inspection · MARPOL Annex VI Survey · MARPOL Annex IV Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4931793
5 June 2014 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4886831
3 January 2014 Administrative Inspection · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4777327
3 January 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4778312
25 September 2013 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4723012
25 September 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4727958
26 August 2013 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4698022
2 November 2012 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4475188
22 October 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4469642
11 September 2012 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4441119
10 September 2012 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4438159
26 July 2012 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4391469
22 July 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4387619
22 July 2012 Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4387620
20 April 2012 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4291457
8 November 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4184772
18 October 2011 Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4171090
5 October 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4161475
30 July 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4101641
30 June 2011 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4063140
16 March 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3968462
10 December 2010 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3908371
9 November 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3888215
1 November 2010 MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3882071
26 October 2010 Annual Inspection · DAPI Audit · MTSA Verification · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3882401
24 June 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3781557
31 March 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3712102
17 February 2010 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3681083
12 February 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3684799
29 January 2010 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3672487
27 January 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3684070
20 January 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3667493
9 January 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3667521
28 August 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3589120
24 August 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3575709
24 August 2009 Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3578012
24 July 2009 Construction Oversight · MARPOL Annex IV Survey · Plan Review (Other than "T") · Deadweight Survey · MTSA/ISPS Verification · DAPI Audit · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex VI Survey · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3544503

Deficiency record · 22

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 August 2024 Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules. While transiting outbound the Columbia River the vessel experienced an oil mist alarm on the port engine that shut the engine down. Request vessel provide report with findings and corrective actions to Sector Columbia River upon departure. 46 CFR 58.05-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2024
Resolution: Resolved to the satisfaction of the Marine Inspector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2023 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any repairs or renewals are made. Vessel reported casualty to port main engine while departing from port. Identify root cause of casualty and provide details for rectification to Sector SF OCMI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2023
Resolution: ABS attended and witnessed sat operation of port m/e.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 20 September 2022 Resolved
Where air pipes to ballast and other tanks extend above the freeboard or superstructure decks, the exposed parts of the pipes shall be of substantial construction. Vent line for dirty oil tank on starboard main deck found fractured and held in place with jubilee patch. ICLL(88) Annex I Reg 20
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2022
Resolution: Accepted as an ABS finding.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 September 2022 Resolved
All access openings in bulkheads at the ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and watertight when closed. Watertight closures for Bosun Locker, EDG room, and escape hatch from engine room found with wastage/deterioration of the gasket channel steel. ICLL(88) Annex I Reg 12
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2022
Resolution: Rectified to the satisfaction of ABS.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 September 2022 Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. STBD dirty oil tank vent found with heavily corroded flame screen. 74SOLAS(14) 11-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2022
Resolution: Rectified to the satisfaction of ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2022 Resolved
Electrical installations shall be such that the safety of.. crew and ship from electrical hazards will be ensured. Surge protector found on the 03 deck with two screws drilled through it into the ships bulkhead.74SOLAS(14)II-1/40.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 September 2022
Resolution: Surge protector removed from service and discarded.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2022 Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Vessels valve/piping under port aft containment was found heavily corroded and with deteriorated valve controls.74SOLAS(14) 11-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2022
Resolution: Rectified to the satisfaction of ABS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 September 2022 Resolved
Ships of all types shall be divided into spaces by thermal and structural divisions having regard to the fire risk of the spaces. Two sections of structural fire protection insulation were removed from the overhead of the 03 deck which is situated below the control space. 74 SOLAS (14)II-1/13-1.1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2022
Resolution: Rectified to the satisfaction of ABS.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 September 2022 Resolved
Where penetrations of watertight bulkheads and internal decks are necessary for access, piping, ventilation, electrical cables, etc., arrangements are to be made to maintain the watertight integrity. Hinged watertight door leading from the engine room to the purifier room(also know as the HFO room) found with a hinged watertight door with 5 of the 6 dogs removed. Fire control/general arrangement plan shows a watertight door at the indicated location. 74SOLAS(14)II-1/13-1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2022
Resolution: Rectified to the satisfaction of ABS.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 3 October 2018 Resolved
LENGTH DIFF: greater/smaller than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 October 2020
Resolution: No issue observed with AIS.
Navigation › Piloting/Steering › Gyro Compass
Issued 17 April 2016 Resolved
Make proper repairs to the vessel's gyrocompass and provide a technicians report attesting to the proper operation of the gyrocompass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 19 April 2016
Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 3 February 2016 Resolved
Provide proper repair to starboard main engine cooling system prior to conducting towing operations with loaded barge to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2016
Resolved 4 February 2016
Resolution: Condition created by operator error (e.g. wrong valve use to top up expansion tank). When tank actually topped up water level remained stable.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 27 December 2015 Resolved
Prove proper operation on Port Main Diesel Engine. Maintain two tug escort as agreed until item is cleared.
Action required: 705 - Other - as specified
Resolved 30 December 2015
Resolution: Satisfactory sea trials conducted following repairs.
Fire Fighting › Means of Escape › Doorways
Issued 12 August 2015 Resolved
The fwd engine room door does not meet the requirements of a fire door. The WTD is not quick acting (6dogs) nor is it standard self closing fire door. Change the door so it opens quickly to provide a fast escape in an emergency and equip door with a closing device. (SOLAS II-2 Reg 13.3.1.5, SOLAS II-2 Reg 13.4.2.1, NFPA 12, NVIC 9-97)
Action required: 705 - Other - as specified
Due 26 August 2015
Resolved 14 August 2015
Resolution: Received documents from Port Engineer indicating the door was not required to be watertight. Crew removed 5 dogs so the door could be quickly opened/closed in case of an emergency.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 22 July 2012 Resolved
Replace/repair clutch pressure sensor on stbd main diesel engine and ensure proper operation of engine IAW 46 CFR 2.01-10(b), prior to departure from next U.S. port.
Action required: 705 - Other - as specified
Resolved 25 July 2012
Resolution: Received statement from master [name withheld] had a spare sensor onboard and replaced the sensor on the stbd main in transit from Sector Saint Pete to Sector New Orleans. The vessel tested the sensor for 24 hours before arrival to the SW pass New Orleans.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 October 2011 Resolved
Provide proof of proper operation of ventilation and remote fuel shut off system to the satisfaction of the attending Class Surveyor and Class report IAW 46 CFR 111.75.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 October 2011
Resolution: ABS provided a class report attesting to repairs.
Engineering › Fuel Oil Service System › Flange
Issued 18 October 2011 Resolved
Repair/replace Heavy Fuel Oil Supply Coupling, due to damage and Inoperative (Thermal Fluid Heater) to the satisfaction of the attending Class Surveyor and provide a class report IAW 46 CFR 61.30.
Action required: 705 - Other - as specified
Resolved 8 November 2011
Resolution: Repaired and Op Test witnessed by ABS with class report T2057754.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 24 June 2010 Resolved
Opened in error.
Due 5 October 2011
Resolved 5 October 2011
Electrical › Electric Generation Source (service) › Generator
Issued 24 June 2010 Resolved
Port Generator is INOP. Vessel allowed to enter New Orleans COTP zone with tug assist to execute repairs.
Action required: 705 - Other - as specified
Due 25 June 2010
Resolved 26 June 2010
Resolution: The port generator was replaced with a new Cummins Model: QSK 19-DM; Serial Number 37233363 Dated: January 2008. In the presence of ABS; generator was tested satisfactory. Generator was run under load and change over between port & stbd was sat.
Engineering › Fuel Oil Service System › Piping
Issued 17 February 2010 Resolved
Vsl is to provide a class survey indicating repairs made to cracked fuel line are sufficient and to verify safety of piping system which may have caused crack.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 February 2010
Resolution: Received satisfactory ABS Class Survey Report.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 29 January 2010 Resolved
Upon completion of repairs to vessels generators contact CG Sector Mobile Command Center @ [phone withheld] to arrange for a CG Marine Inspector to be present with Class Surveyor to witness testing of generators.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2010
Resolved 30 January 2010
Resolution: Vessel completed repairs to both generators. We witnessed testing of generators with ABS ([name withheld]). All tests SAT.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 24 August 2009 Resolved
Faulty overspeed trip sensors failed shutting the port main down.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2009
Resolution: Wartsila tech replaced sensors and Engine Safety Module. ABS verified repairs and submitted their report (scanned into activity).

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.