Records from 2010 to 2025. Most recent: inspection, 19 September 2025.
Documentation record
Registered dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
Registered tonnagegross 11,147 / net 11,147
ITC dimensions (L × B × D)559.8 ft × 74.0 ft × 40.1 ft
ITC tonnagegross 13,462 / net 8,791
BuilderVT HALTER MARINE INC · PASCAGOULA, MS, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 27 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11147 - Regulatory (Subpart C or D), Gross Ton
13462 - Convention (Subpart B), Gross Ton
11147 - Regulatory (Subpart C or D), Net Ton
8791 - Convention (Subpart B), Net Ton
27023 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
19 September 2025
Internal Structural Exam · COI Inspection · MARPOL Annex II Examination · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8207424
27 June 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8178523
19 September 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8009408
14 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7912042
29 June 2023
Internal Structural Exam · Drydock Exam · Periodic Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7726116
8 February 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7633921
18 October 2022
MTSA Verification · Annual Inspection · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7575033
30 August 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7300622
22 May 2020
In-Service Inspection · COI Inspection · Hull Examination · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6965522
14 May 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6953035
30 September 2019
MTSA/ISPS Verification · Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6825787
23 October 2018
MTSA/ISPS Verification · Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination · Periodic Inspection · MARPOL Annex II Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6563069
27 March 2018
Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370470
8 November 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6303206
11 October 2017
MARPOL Annex II Examination · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6285790
1 August 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6226944
26 April 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6134082
17 March 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6106496
24 February 2017
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6094070
4 November 2016
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6033874
8 August 2016
Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5965987
17 March 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5835024
16 August 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5222472
31 July 2015
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5202213
29 June 2015
Drydock Exam · COI Inspection · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5167638
31 December 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5058095
29 July 2014
Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4929044
13 March 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4815327
2 October 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4729043
26 September 2013
Periodic Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex II Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4726370
24 July 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4664500
19 October 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4467645
15 October 2012
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4461906
5 September 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4433054
18 January 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4232992
22 August 2011
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4124225
17 March 2010
Plan Review (Other than "T") · Construction Oversight · MTSA/ISPS Verification · Ballast Water Examination · Initial Certification · MARPOL Annex II Examination · Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3697369
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2018
Resolved
Active leak from bottom of port generator start air line moisture trap. Repair/replace trap.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 19 November 2018
Resolution: replaced moisture trap
Documentation › Certificates/Documents › International Load Line Certificate
Issued 11 October 2017
Resolved
The International Load Line Certificate (ILLC) reflects CargoMax for Windows, version 1.21,Rev 0. The version on board and reflected on the approved trim & Stability Booklet has been updated to Version 2. ertificate issuing authority (ABS) to verify and update ILLC and any associated documents accordingly.
Action required: 705 - Other - as specified
Due 11 December 2017
Resolved 8 November 2017
Resolution: ABS Issued new ILLCertificate reflecting correct stability letter
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 9 August 2016
Resolved
Conduct annual 1.5 x MAWP hydro of cargo piping.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 10 August 2016
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 31 July 2015
Resolved
Sector Miami originally issued a requirement, due to the Port Generator failing a Reverse Power Relay test, on 29JUN15 (MISLE Activity #5167638). In administrative review, the vessel is prohibited from running its generators in parallel operation (or paralleling its generators) until the Port Generator satisfactorily passes a Reverse Power Relay test, witnessed by a USCG [name withheld] 15AUG15.
Due 15 August 2015
Resolved 15 August 2016
Engineering › Generator (propulsion/auxiliary-electric) › Reverse Power Protection Relay Circuitry
Issued 29 June 2015
Resolved
Port generator failed Reverse Power Relay test. Def to be cleared before cargo discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2015
Resolution: Modified and Re-administered CG-835 requirement.