Records from 2001 to 2010. Most recent: inspection, 20 October 2010.
Inspection history · 35
20 October 2010
COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3873948
14 April 2009
ISPS II Exam · MARPOL Annex II Examination · Ballast Water Examination · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3448727
17 August 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3300958
8 April 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3196035
7 April 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3178811
20 March 2008
COC-CHEM Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3165937
13 January 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3128136
22 June 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2970264
22 June 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2975641
13 June 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2960651
30 March 2007
MARPOL Annex II Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2898417
26 March 2007
ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-CHEM Renew · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2894946
25 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2894875
3 August 2006
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2734824
26 July 2006
MARPOL Annex II Examination · MARPOL Annex I Examination · Ballast Water Examination · COC-CHEM Annual · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2725470
16 July 2005
Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2428711
11 March 2005
COC-CHEM Renew
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2308466
22 February 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2296730
10 February 2005
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2289965
8 December 2004
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2260392
24 June 2004
MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2109262
4 March 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2018932
31 May 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1806229
11 March 2003
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1755564
26 July 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1652439
26 July 2002
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1653607
24 July 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1653933
26 April 2002
Security Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1609864
25 April 2002
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1609326
25 April 2002
Administrative Inspection · Ballast Water Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1609368
3 April 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600666
17 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1494741
2 September 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 293386
10 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286987
10 February 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1058452
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 22 June 2007
Resolved
Sea suction/chest damaged (wasted, cracked or holed) allowing fuel oil from No. 1.5 F.O, tank to egress through sea suction pipe (sea chest) and entering the water. Temporary repairs effected; sea suction blanked off and condition of class issued for permanent repairs. Class report for permanent repairs required prior to returning to U.S. after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 December 2007
Resolved 9 August 2007
Resolution: Received classification certificate stating that the deficiency has been corrected.
Personnel › Certificates/Documents/Licenses › License, Second Mate
Issued 11 March 2003
Resolved
UK Endorsement for Phillipine 2nd mate license expired. Provide to USCG prior to departing the port of NY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2003
Resolved 11 March 2003
Resolution: The endorsement was recieved prior to departing the vessel and cleared on the spot.
Navigation › Collision/Grounding Avoidance
Issued 23 April 2002
Resolved
Vessel was authorized to deviate from the requirement of 33 CFR 164.37(a) and depart the Port of Corpus Christi and enter the Port of Point Comfort with an inoperable secondary radar with the understanding that the equipment would be operational prior to departure from Point Comfort.
LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2003
Resolution: Onboard to conduct a COC renewal exam and found subject radar fully operational, cleared same this date.
Fire Fighting › Structural - A Class Divisions
Issued 3 April 2002
Resolved
MULTIPULE "A" CLASS DOORS THROUGHOUT VESSEL DO NOT MEET "A" CLASS REQUIREMENTS.
PROVIDE CLASS REPORT REGUARDING REPAIRS NEEDED BY 03 MAY 02 LEGACY COMPONENT DESC: Openings - Doors
Condition: Design Flaw
Due 3 May 2002
Resolved 24 July 2002
Resolution: Doors were in compliance with solas.