MAURY USCG vessel records
← All vessels

EURODAM

EURODAM is a 2008 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 2016, most recently in March 2026, along with 41 deficiencies and 5 operational controls.

Records from 2016 to 2026. Most recent: inspection, 22 March 2026.

Built
2008
Last inspected
22 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 March 2026
…with no type recorded18
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9378448
865188
Flag
NETHERLANDS
Maury page id
psix-865188

Documentation record

Tonnage as PSIX records it45080 - Displacement, Ton
91247 - Dead Weight, Ton
86273 - Convention (Subpart B), Gross Ton
53711 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DUGAN PEARSALL Tank Barge · MISLE 937919 · 3 June 2017 · activity 6165471SHAUNA KAY Tank Barge · MISLE 12616 · 6 May 2017 · activity 6140571

Inspection history · 81

22 March 2026 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8327672
22 September 2025 PSC A · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8237466
2 August 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8202052
21 July 2025 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8191093
21 July 2025 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8191362
2 April 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8102630
29 March 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8101707
25 September 2024 COC-CVE Annual · PSC A
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8009386
23 July 2024 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8016476
8 May 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7927199
9 April 2024 Deficiency Check · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7891107
6 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7908384
16 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7892469
6 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7883600
14 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7883593
24 January 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7865239
9 December 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7842529
27 October 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7815328
27 October 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7815353
12 October 2023 COC-CVE Annual · PSC A
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7807147
12 July 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7833593
14 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7763352
7 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7760393
24 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7745783
17 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7744905
15 May 2023 PSC B · Deficiency Check · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7688414
29 April 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7726461
28 April 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7725867
13 February 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7636150
21 November 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7598170
29 October 2022 Ballast Water Examination · COC-CVE Annual · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579931
27 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7584802
12 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576295
23 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542031
1 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7522585
21 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483382
15 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7478765
13 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7476785
25 May 2022 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7484284
14 May 2022 COC-CVE Quarterly
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7439526
1 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7404155
5 February 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7391241
15 November 2021 COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7348372
3 November 2021 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7344864
11 April 2020 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6998703
18 March 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928673
16 February 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6910023
22 January 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6894148
1 December 2019 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6862058
22 November 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6860431
31 October 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6846590
17 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6814013
5 September 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6804588
30 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799252
30 August 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6799997
29 August 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6797791
26 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6795636
24 August 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6797550
15 July 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6759076
6 July 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6746275
20 May 2019 ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6673773
30 April 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6673816
23 April 2019 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6668997
17 December 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6611310
19 November 2018 Administrative Inspection · ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6582329
30 August 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6580151
14 July 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6520747
26 May 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6424319
21 May 2018 Ballast Water Examination · ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6419925
8 May 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405940
23 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6328393
19 November 2017 COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6310862
8 September 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6262953
23 August 2017 Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6250030
3 June 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6165471
27 May 2017 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6155716
22 May 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6152458
6 May 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6140571
28 November 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6048679
19 November 2016 Deficiency Check · COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6041344
23 March 2016 Ballast Water Examination · COC-CVE Quarterly · Deficiency Check · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5835102

Deficiency record · 41

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 September 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. PSCO observed one for forward Nitrogen Accumulator Units (NAU cylinder bank) servicing high fog skid jumps, with one cylinders at 130 bar. Pressure Per manufacturer, NAU cylinders shall be maintained at a minimum of 180 bars. 74 SOLAS 20 II-2/14.1.2.17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2025
Resolution: Resolved prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 September 2025 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed rudders not working when steering was engaged on tender boat 11. Emergency steering was working. It was discovered that hydraulic oil was low and had to be refilled. 74 SOLAS 20 III/20.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 September 2025 Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and life raft embarkation deck. For this purpose, the following functional requirements shall be met: 1. Safe escape routes shall be provided. PSCO observed multiple electric wheelchairs in passenger stairwell landings in way of evacuation routes to embarkation deck, not allowing for a safe means of escape. 74 SOLAS 20 II-2/13.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 22 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 September 2025 Resolved
Fire dpprs in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. PSCO observed FSD 06.4.25 and FSD 06.1.56 in the crew stairwell, zone 4 and zone 1 did not fully latch upon closing as well as FSD 0D.4.03 at emergency escape on deck 0. 74 SOLAS 20 II-2/9.4.11.5.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 22 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 September 2025 Resolved
Spaces are classified according to their fire risk as shown categories (1) to (14). PSCO observed combustibles stowed in technical spaces Ivo cabins B176, B170, B161, B004, B003, B009, B059 and combustible items stowed in fire stations B04.19, B06.05 and fire station/locker B04.19, B06.05 and fire station/locker B06.03 74 SOLAS 20-II-2/9.2.2.3.2.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 September 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 September 2024 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed plastic garbage cans containing combustible waste in the crew mess, main galley and stowage of used batteries throughout the ship. 74 SOLAS 20 II-2/4.4.2
Action required: 10 - Deficiency Rectified
Resolved 30 September 2024
Resolution: All plastic garbage cans removed/replaced with non combustible cans.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 September 2024 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO observed hose ports on fire screen doors A.4.32, A.1.125 unable to close. Additionally, the lock on fire screen door A.3.05 was observed to allow light through the space, therefore not maintaining the fire boundary. 74 SOLAS 20 II-2/9.4.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 30 September 2024
Resolution: A doors adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 September 2024 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed instances of improper stowage including rags stowed in fire station B.06.06, A floor waxing machine stowed in the AC space behind fire door 1.4.30. In numerous boxes and other combustible items stowed in the celling space under the tiered seating in the theater. 74 SOLAS 20 II-2/9.2.2.3.2.2
Action required: 10 - Deficiency Rectified
Resolved 30 September 2024
Resolution: All combustible materials removed from space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 April 2024 Resolved
74 SOLAS(2009)II-2/13.1.2 Escape routes shall be maintained in a safe condition, clear of obstacles . PSCO obcerved free-standing signage obstructing escape routes within stairway from the spa.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2024
Resolved 9 April 2024
Resolution: Ships crew romoved the free-standing signage.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 April 2024 Resolved
74 SOLAS(2009)II-2/13.1.3 Additional aids for escape shall be provided as necessary to ensure accessibility, clear markings and adequate designed for emergency situations. PSCO observed during the passanger evacuation drill that a dual sliding glass door on deck 3 stbd side leading to passanger muster location did not open due to a known error that causes the door to remain closed until the door is reset.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2024
Resolved 13 April 2024
Resolution: 3 ADA Sliding doors on deck 3, at frames starboard 60, 280 and port 175; now satisfactorily provided with power off switch and clear instructions psoted for manually opening the door. This arrangement to be considered permanent.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 April 2024 Resolved
74 SOLAS(2009)II-2/9.2.2.3.2.2 Spaces are clssified according to their fire risk as shown in category(1) to (14). A/C machinery station 4/5 located behind FSD 05.5.15 is a category space (10) space where storage of combustables is prohibited. PSCO observed storage of cardboard boxes containing A/C filters.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2024
Resolved 9 April 2024
Resolution: COntents was removed prior finishing the exam.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 October 2023 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. door located in Ledo Galley escape route had original "crash bar" push handle removed and retrofitted with a rotational handle. 74SOLAS 04 II-2/13.3.2.6.2
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2023
Resolution: Vessel provided Class dispensation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 October 2023 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. Doors leading into Neptune Lounge have gaps between the door and the door frame allowing smoke and fire penetration. 74 SOLAS 04 II-2/9.4.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2023
Resolution: Vessel provided Class dispensation.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects remain fit to proceed to sea. Vessel has crack along weld seam under mooring post on the stbd side under #3 lifeboat. 74 SOLAS 20 I/11
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 12 October 2023
Resolution: Condition of class issued by LR. Final weld repair complete as attested to by class survey report.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2023 Resolved
Hoses specified in this chapter as "fire hoses" shall together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. Spanner wrenches were missing at fire stations D.02.26, D.03.13 and D.03.13A (Auxiliary Room and Evaporator Room) at the time of inspection. Spanner wrench was replaced at fire station D.03.13 but are still missing at the other two locations. 74 SOLAS 20 II-2/2.3.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 May 2023
Resolution: Spanner wrenches were replaced. Pictures sent after completion of the examination.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 May 2023 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. PSCOs asked several galley crews in the following locations including the Asian Galley Deck on deck 11, the Lido deck Italian deck galley on deck 09, and the lido deck sweet spot galley space on deck 09, were unable to demonstrate how to shut off galley ventilation. 74 SOLAS 20 II-2/15.2.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 May 2023
Resolved 30 May 2023
Resolution: Received Class Report attesting to satisfaction of training.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2022 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs; fire detection and fire alarm systems. Fire detection system was found with multiple active faults, fire detector is inoperable in incinerator space. 74 SOLAS 20 II-2/14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 October 2022
Resolution: Vessel replaced smoke detector onscene, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 October 2022 Resolved
Openings in bulkheads and decks in passenger ships. The doors shall be capable of release also individually from a position at both sides of the door. Release switches shall have an on-off function to prevent automatic resetting of the system... Release switch funtion was inoperable on FSD 02.1.02 and FSD 02.02.84. 74 SOLAS 20 II-2/9.4.1.1.5.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2022
Resolved 29 October 2022
Resolution: Received class report with mitigation plan, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 May 2022 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Numerous members in the galley were unfamiliar on how to operate the high fog fire fighting system. 74 SOLAS 20 II-2/15.2.2.1
Action required: 10 - Deficiency Rectified
Due 14 May 2022
Resolved 14 May 2022
Resolution: Crew members received additional training in the galley for fire fighting.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 May 2022 Resolved
Every crew memeber with assigned emergency duties shall be famiiar with these duties before the voyage. Several crew members were unfamiliar with their duties during abandoned ship drill. 74 SOLAS 20 III/19.2.1
Action required: 10 - Deficiency Rectified
Due 14 May 2022
Resolved 14 May 2022
Resolution: Crew memebers received additional training on their duties during emergencies.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 15 November 2021 Resolved
The company and the ships shall comply with requirements of the International Safety Management Code. The engineering staff on watch failed to log the Coast Guard Examiners on the visitors log when they entered the ships engineering space. SOLAS 20 IX/3.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2021
Resolved 29 December 2021
Resolution: Observed training records.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 15 November 2021 Resolved
Survival craft muster and embarkation arrangements. Administration may permit such ladders to be replaced by approved devices to afford access to the survival craft when waterborne. The ships crew did not deploy the decent devices and many crewmembers were not familiar with their use. SOLAS 20 III/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2021
Resolved 29 December 2021
Resolution: Observed training records.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 November 2021 Resolved
On-board training in the use of the ship's life-saving appliances including survival craft equipment, and in use of the ship's fire-extinguishing appliances shall be given as soon as possible but not later than two weeks after a crew member joins the ship. SOLAS 20 III/19.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2021
Resolved 29 December 2021
Resolution: Observed training records.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2021 Resolved
The following fire protection systems shall be kept in good working order as to ensure their required performance if a fire occurs; structural fire protection including fire resisting division, and protection of openings and penetrations in these divisions. B-15 fire doors P.9.2.03 and P.2.04 were unable to self-close properly due to missing hinge pin and/or the lower section of the door was split. SOLAS 20 II-2/14.2.1.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 December 2021
Resolved 29 December 2021
Resolution: Witnessed satisfactory test of doors.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2021 Resolved
Fire doors in main vertical zone bulkheads, galley boundary doors and stairway enclosures. The approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s. Fire doors 11.05.05, 11.06.03, 09.5.28, 09.5.20, 10.13.15,09.2.66,028.2.35,05.5.08, and 05.2.39 closed in under 10s. SOLAS 20 II-2/9.4.1.1.5.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 December 2021
Resolved 29 December 2021
Resolution: Witnessed satisfactory test of doors.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 November 2021 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and weather decks, opening shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Rolling shutter 09.2.05 and 09.2.03 failed to close upon activation of local release. SOLAS 20 II-2/9.4.1.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 December 2021
Resolved 29 December 2021
Resolution: Witnessed satisfactory test of shutters.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 December 2019 Resolved
The machinery...fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. Emergency generator has exhaust leak. -74SOLAS(04)II-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 December 2019
Resolution: The emergency generator was tested on load during the undersigned surveyor's attendance. The exhaust gaskets were changed and there was no visible signs of leakage from the crew.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2019 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures...shall be self-closing. FSD 02.1.82 would not automatically close when activated. -74SOLAS(14)II-2/9.4.1.1.5.1
Action required: 10 - Deficiency Rectified
Resolved 1 December 2019
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 December 2019 Resolved
Every crew member shall be given instructions which shall include but not limited to: operation and use of the ships inflatable life rafts. The crew of the starboard side forward life raft station did not display adequate knowledge of launching a life raft. -74SOLAS(14)III/19.4.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 December 2019
Resolution: The vessel provided additional training for the life raft squads and video evidence was presented to the undersigned surveyor.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 1 December 2019 Resolved
The public address system shall be clearly audible above the ambient noise in all spaces prescribed by paragraph 7.2.2.1 of the code. The public address system shall be a loudspeaker installation enabling the broadcast of messages into all spaces where crew members or passengers are normally present. The crew smoking room on the bulkhead deck did not have any alarm or public address system installed. -74SOLAS(14)III/6.5.2 LSA CODE 7.2.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 December 2019
Resolution: The crew smoking room on Deck A was fitted with a public address speaker which was satisfactorily demonstrated to attending surveyor.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 September 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship. Ship was unable to start one of the steering gear pumps on the starboard Azipod.
Action required: 10 - Deficiency Rectified
Resolved 5 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship. Ship was unable to place the port Azipod on line due to a high speed circuit breaker not responding with no indication of fault. 2004SOLAS 1/11 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 16 September 2019
Resolution: Technical shore support directed the crew to restart the Azipod control program. This corrected the failure in communication within the portside Azipod control program. The Azipod returned to normal operation and has been deemed in good working order.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2019 Resolved
Low Location lighting should lead to the exit door handle . LLL on deck 1 stair 3 in MVZ 2 did not lead to the handle.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2019
Resolution: Vessel installed new LLL tape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2019 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. THE SEALS ON THE VESSELS AZIPOD DRIVE SYSTEM SHALL BE SUFFICIENTLY INSTALLED TO ENSURE THERE IS NO DISCHARGE OF THE UNITS LUBRICATING FLUID.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2019
Resolution: REPAIRS MADE ON AZIPODS, DETAILED IN CLASS REPORT. ALL SAT.
Personnel › Training › Passenger Safety
Issued 19 November 2017 Resolved
78 STCW (11 cons.) I/14.1.5 - Each administration shall ensure that seafarers are familiarized with their specific duties, ship arrangements, installations, equipment, and procedures, relevant to their routine or emergency duties. The Cabin Evacuation Stewards did not demonstrate proper evacuation techniques as per ship procedures.
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 19 November 2017
Resolution: Training conducted while team was still onboard.
Construction/Loadline › Structures › Door
Issued 19 November 2017 Resolved
74 SOLAS (14) II-2/13.3.1.1 - Stairways and Ladders shall be so arranged as to provide ready means of escape to the lifeboat and life raft embarkation deck from passenger and crew accommodation spaces and from spaces in which the crew is normally employed, other than machinery spaces. As per MSC guidelines SOLAS -25, there is a room in room arrangement in the maitre hotel office 2.1.02.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 23 December 2017
Resolution: Sector Miami has accepted Lloyds Register concept meeting review stating the maitre hotel office is used on a limited basis not requiring the vessel to install audible alarm in that space.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 November 2017 Resolved
74 SOLAS (14) ii-2/13.1.2 - Escape routes shall be maintained in a safe condition, clear of obstacles. 1) Evacu-Trac obstructing aft crew stairwell 2) Security equipment stored in midship stairwell, deck A.
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 23 December 2017
Resolution: Sector Miami has accepted Lloyds memorandum risk assessment allowing security equipment to remain on deck A mid-ship as it is considered not in way of the escape route.
Engineering › Steam System (main) › Piping
Issued 19 November 2016 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. The main steam pipe line located above the high pressure mist system on portside was found leaking onto the high presssure mist system. 50ac.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 28 November 2016
Resolution: Vessel completed repairs to leaking steam piping system.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 19 November 2016 Resolved
Smaller, enclosed rooms within a space that have less than 30% communicating openings to that space are considered separate spaces. The fire integrity of boundaries of such smaller rooms shall be as prescribed in tables 9.3 and 9.4. The Sous Chef Office, located on deck 3 does not meet the categorization required based on its current use as an office.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 28 November 2016
Resolution: Vessel properly classified space.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 23 March 2016 Resolved
A vessel owner/oeprator with a capacity of 250 or more bbls of oil shall provide Transfer Procedures that meet the requirements of 33CFR155.750 for transferring to or from the vessel or tank to tank. PSCO found vessel's current Oil Transfer Procedures not in compliance with 33CFR155.570. 33CFR155.720 & 33CFR155.750.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 17 January 2017
Resolution: Approved by Sector San Juan in Vessel Speical Notes
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 March 2016 Resolved
Hold-back hooks not subject to Central Control Station release are prohibited. PSCO found Fire Door #FSD0A.3.7.3 missing the magnetic hold-back but a manual hold-back hook installed in it's place.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2016
Resolved 23 March 2016
Resolution: Ship's crew installed a proper magnetic hold-back for the fire door.

Ownership record