MAURY USCG vessel records
← All vessels

DUGAN PEARSALL

DUGAN PEARSALL is a 2008 tank barge. The Coast Guard has recorded 44 inspections since 2008, most recently in June 2026, along with 18 deficiencies.

Records from 2008 to 2026. Most recent: inspection, 5 June 2026.

Built
2008
Last inspected
5 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 5 June 2026
…with no type recorded17
Operational controls None recorded without a removal date
Years with a record 19 calendar years (2008–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE6402
937919
Flag
UNITED STATES
Maury page id
psix-937919

Documentation record

Registered dimensions (L × B × D)265.6 ft × 64.5 ft × 23.5 ft
Registered tonnagegross 3,262 / net 1,792
ITC dimensions (L × B × D)265.6 ft × 64.5 ft × 23.5 ft
ITC tonnagegross 3,262 / net 1,792
BuilderGUNDERSON MARINE LLC · PORTLAND, OR, UNITED STATES · built 2008
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3262 - Convention (Subpart B), Gross Ton
1792 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AS CARLOTTA Freight Ship · MISLE 1055831 · 7 January 2018 · activity 6333773EURODAM Passenger (Inspected) · MISLE 865188 · 3 June 2017 · activity 6165471BOLETTE Passenger (Inspected) · MISLE 16340 · 4 September 2016 · activity 5992247

Inspection history · 44

5 June 2026 MARPOL Annex VI Survey · Deficiency Check · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8392641
28 May 2025 MARPOL Annex VI Survey · Annual Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8082791
22 May 2024 MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7877776
10 May 2023 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694864
18 April 2023 MARPOL Annex I Examination · COI Inspection · Deficiency Check · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7671274
22 February 2023 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7639939
16 May 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7452149
20 April 2022 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7434629
16 February 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7139529
29 July 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7019485
17 July 2019 MARPOL Annex I Examination · MTSA Verification · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6753682
19 December 2018 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6600509
25 May 2018 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6423729
7 May 2018 Internal Structural Exam · COI Inspection · Cargo Tank Internal · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405296
7 January 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6333773
3 June 2017 Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6165471
17 December 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6059340
6 October 2016 MARPOL Annex I Examination · MTSA Verification · Annual Inspection · Internal Structural Exam · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6016772
4 September 2016 Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5992247
14 June 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5908123
27 October 2015 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5755976
31 October 2014 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5014522
7 July 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4914559
6 July 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4913111
14 June 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4888498
8 June 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4884458
19 September 2013 MTSA Verification · MARPOL Annex VI Survey · Drydock Exam · Internal Structural Exam · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4718719
27 July 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4666307
19 December 2012 Deficiency Check · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4505062
4 December 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4496155
21 November 2012 Annual Inspection · Drydock Extension
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4487193
15 September 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4442564
5 August 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4401843
3 November 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4181756
25 September 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4153793
12 August 2011 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4116335
19 December 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3913416
9 November 2010 Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3888656
3 January 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3657988
20 September 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3599979
21 March 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3437640
11 November 2008 Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3361051
4 September 2008 Construction Oversight · Initial Certification · Deadweight Survey · MARPOL Annex II Examination · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3348467
12 August 2008 Construction Oversight · Load Line/Change of Employment
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3291637

Deficiency record · 18

01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 5 June 2026 Resolved
Current SOPEP was not onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2026
Resolved 29 June 2026
Resolution: Received current SOPEP and TVRP.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 May 2025 Resolved
Where firefighting equipment is not required, but is installed, the equipment and its installation must be of an approved type. The installed CO2 cylinder is actively leaking. Vessel cannot operate the TFH until the CO2 system is tested and deemed operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
Resolution: semi-portable system was replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 May 2025 Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. Vessel cannot conduct cargo operations with the exception to receive the minimal amount required to conduct a cargo pump relief valve operational test.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2025
Resolution: Received pictures showing issue has been resolved.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 28 May 2025 Resolved
Where pumps and compressors are driven by a prime mover in an adjacent gas safe space, the bulkhead or deck must be gas tight. The gas tight bulkhead seal for the stbd cargo pump is deteriorated and needs replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
Resolution: Received pictures showing issue has been resolved.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 28 May 2025 Resolved
Oil tankers and offshore oil barges with an overall length of less than 400 feet must carry appropriate equipment and supplies for the containment and removal of on-deck oil spills of at least 7 barrels. Inventory does not match equipment present.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
Resolution: Received pictures showing issue has been resolved.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 18 April 2023 Resolved
Each oil tanker of 150 gross tons and above, ship of 400 gross tons and above other than an oil tanker shall maintain an Oil Record Book Part I (Machinery Space Operations). An oil tanker of 150 gross tons and above or a non oil tanker that carries 200 cubic meters or more of oil in bulk, shall also maintain an Oil Record Book Part II (Cargo/Ballast Operations). During inspection, marine inspector discovered multiple inconsistencies in the ORB part II and vessel did not have a ORD part I on board. 46 CFR 151.25 (a),MARPOL (2017 cons) Annex I Reg 17
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 April 2023
Resolution: Provided ORB I
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 18 April 2023 Resolved
For each ship subject to regulations 5 and 6 of this Annex, details of fuel oil for consumption purposes delivered to and used on board shall be recorded by means of a bunker delivery note in the form specified in appendix V and retained on board for a period of three yeas. Vessel could not provide bunker delivery notes to the marine inspector. MARPOL (2017 cons) Annex VI Reg 18.5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 April 2023
Resolution: Operator will provide BDN's in the future
14 - Pollution Prevention › 146 - MARPOL Annex VI › Quality of fuel oil
Issued 18 April 2023 Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered as per MEPC.182(59) and retained for a period of not less than 12 months. The sample is to be signed by the supplier's rep and officer in charge of the bunker operation. Vessel could not provide accurate samples to inspector. MARPOL (2017 cons) Annex VI Reg 18.8.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 19 April 2023
Resolution: Operator will provide samples in the future
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023 Resolved
Each cable entrance into explosionproof or flameproof equipment must be made with approved seal fittings, termination fittings, or glands that meet the requirements of 111.105–9. Marine inspector identified unapproved termination fittings at the port aft emergency shut down and the forward center lighting mast. 46 CFR 111.105-17(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 29 June 2023
Resolution: Received photographic evidence clearing def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023 Resolved
Through runs of marine shipboard cable meeting subpart 111.60 of this part are required for all hazardous locations. Armored cable may be used to enhance ground detection capabilities. Marine inspector identified damaged electrical cable near port side containment that is powering forward center mast lights. 46 CFR 111.105-17(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 29 June 2023
Resolution: Received photographic evidence clearing def.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2023 Resolved
Bulkheads of galleys, paint and lamp lockers, and emergency generator rooms shall be of “A” Class construction. Vessel is utilizing an unapproved container for fuel samples, paints and solvents. Vessel is to obtain an approved type flammable locker for the storage of these items. 46 CFR 32.57-10(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2023
Resolved 29 June 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 18 April 2023 Resolved
A pressure gage shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Port aft manifold pressure gage is missing. 46 CFR 32.50-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2023
Resolved 29 June 2023
Resolution: Received photographic evidence clearing def.
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 16 February 2021 Resolved
The audible alarm on the Thermal Fluid Heater is not operational. Operational tests and checks of all safety and limit controls must be conducted by the owner, chief engineer, or person in charge at the inspection for certification, periodic inspection, and when directed by the Officer in Charge, Marine Inspection, to determine that the control components and safety devices are functioning properly and are in satisfactory operating condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2021
Resolved 2 March 2021
Resolution: Rcvd video of working audible alarm.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 31 October 2014 Resolved
Properly outfit each non rising stem valve, level operated valve, or other valve with an indicator to show whether the valve is opened or closed, IAW 46 CFR 56.20-9
Action required: 705 - Other - as specified
Due 15 November 2014
Resolved 21 November 2014
Resolution: Valves properly labeled.
Deck/Cargo › Cargo Heating › General
Issued 31 October 2014 Resolved
Prove proper operation of the thermal fluid heater, currently not being used for transfers, IAW 46 CFR 61.30-20.
Action required: 705 - Other - as specified
Due 15 December 2014
Resolved 21 November 2014
Resolution: Witnessed proper operation of the thermal fluid heater.
Electrical › Electric Supply System (service) › Cable
Issued 31 October 2014 Resolved
Properly insulate 3 inches of exposed cable starboard side aft, IAW 46 CFR 111.60-21.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 14 November 2014
Resolution: Installed proper cable insulation.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 November 2012 Resolved
Issued 835 for presence of improperly approved electrical equipment in hazardous locations, directing vessel to carry grade D and E cargoes until cargo gauging sensors are either replaced or tested in accordance with 46 CFR 111.105 (IEC 60079).
Action required: 705 - Other - as specified
Resolved 19 December 2012
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 12 August 2011 Resolved
Effect permanent repair of .25" crack in cago tank #4 at the deep well prior to completion of ABS intermediate survey to occur late October or early November 2011.
Action required: 705 - Other - as specified
Due 20 November 2011
Resolved 3 November 2011
Resolution: Vessel provided satisfactory repair to deep well.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.