← All vessels
DUGAN PEARSALL
Tank Barge · Barge class · Built 2000s · USCG Northwest District (CGD-NW) · Other hulls named DUGAN PEARSALL
DUGAN PEARSALL is a 2008 tank barge. The Coast Guard has recorded 45 inspections since 2008, most recently in June 2026, along with 18 deficiencies.
Records from 2008 to 2026. Most recent: inspection, 5 June 2026.
- Built
- 2008
- Last inspected
- 5 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1208933
WDE6402
937919
Flag
UNITED STATES
367379790
Maury page id
psix-937919
Inspections, by type
…with no type recorded17
Years with a record
19 calendar years (2008–2026)
The 45 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)265.6 ft × 64.5 ft × 23.5 ft
Registered tonnagegross 3,262 / net 1,792
ITC dimensions (L × B × D)265.6 ft × 64.5 ft × 23.5 ft
ITC tonnagegross 3,262 / net 1,792
BuilderGUNDERSON MARINE LLC · PORTLAND, OR, UNITED STATES · built 2008
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 April 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3262 - Convention (Subpart B), Gross Ton
1792 - Convention (Subpart B), Net Ton
1792 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE6402MMSI 367379790 · active · voluntarily equipped · granted 1 September 2018, expires 8 October 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspected as a tow unit · 7
The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.
AS CARLOTTA Freight Ship · MISLE 1055831 · 7 January 2018 · activity 6333773EURODAM Passenger (Inspected) · MISLE 865188 · 3 June 2017 · activity 6165471BOLETTE Passenger (Inspected) · MISLE 16340 · 4 September 2016 · activity 5992247CARNIVAL ADVENTURE Passenger (Inspected) · MISLE 26988 · 14 June 2014 · activity 4888498GRAND PRINCESS Passenger (Inspected) · MISLE 474882 · 8 June 2014 · activity 4884458OOSTERDAM Passenger (Inspected) · MISLE 652130 · 25 September 2011 · activity 4153793LOTUS A Freight Ship · MISLE 1094743 · 19 December 2010 · activity 3913416Inspection history · 45
5 June 2026
MARPOL Annex VI Survey · Deficiency Check · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8392641
28 May 2025
MARPOL Annex VI Survey · Annual Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8082791
22 May 2024
MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7877776
10 May 2023
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694864
18 April 2023
MARPOL Annex I Examination · COI Inspection · Deficiency Check · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7671274
22 February 2023
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7639939
16 May 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7452149
20 April 2022
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7434629
16 February 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7139529
29 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7019485
17 July 2019
MARPOL Annex I Examination · MTSA Verification · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6753682
19 December 2018
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6600509
25 May 2018
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6423729
7 May 2018
Internal Structural Exam · COI Inspection · Cargo Tank Internal · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405296
7 January 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6333773
3 June 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6165471
17 December 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6059340
6 October 2016
MARPOL Annex I Examination · MTSA Verification · Annual Inspection · Internal Structural Exam · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6016772
4 September 2016
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5992247
14 June 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5908123
27 October 2015
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5755976
31 October 2014
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5014522
7 July 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4914559
6 July 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4913111
14 June 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4888498
8 June 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4884458
19 September 2013
MTSA Verification · MARPOL Annex VI Survey · Drydock Exam · Internal Structural Exam · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4718719
27 July 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4666307
19 December 2012
Deficiency Check · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4505062
4 December 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4496155
21 November 2012
Annual Inspection · Drydock Extension
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4487193
15 September 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4442564
5 August 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4401843
3 November 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4181756
25 September 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4153793
12 August 2011
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4116335
19 December 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3913416
9 November 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3888656
3 January 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3657988
17 December 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3651545
20 September 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3599979
21 March 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3437640
11 November 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3361051
4 September 2008
Initial Certification · Deadweight Survey · MARPOL Annex II Examination · Construction Oversight · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3348467
12 August 2008
Construction Oversight · Load Line/Change of Employment
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3291637
Deficiency record · 18
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 5 June 2026
Resolved
Current SOPEP was not onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 May 2025
Resolved
Where firefighting equipment is not required, but is installed, the equipment and its installation must be of an approved type. The installed CO2 cylinder is actively leaking. Vessel cannot operate the TFH until the CO2 system is tested and deemed operational.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 May 2025
Resolved
Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. Vessel cannot conduct cargo operations with the exception to receive the minimal amount required to conduct a cargo pump relief valve operational test.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 28 May 2025
Resolved
Where pumps and compressors are driven by a prime mover in an adjacent gas safe space, the bulkhead or deck must be gas tight. The gas tight bulkhead seal for the stbd cargo pump is deteriorated and needs replacement.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 28 May 2025
Resolved
Oil tankers and offshore oil barges with an overall length of less than 400 feet must carry appropriate equipment and supplies for the containment and removal of on-deck oil spills of at least 7 barrels. Inventory does not match equipment present.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 18 April 2023
Resolved
Each oil tanker of 150 gross tons and above, ship of 400 gross tons and above other than an oil tanker shall maintain an Oil Record Book Part I (Machinery Space Operations). An oil tanker of 150 gross tons and above or a non oil tanker that carries 200 cubic meters or more of oil in bulk, shall also maintain an Oil Record Book Part II (Cargo/Ballast Operations). During inspection, marine inspector discovered multiple inconsistencies in the ORB part II and vessel did not have a ORD part I on board. 46 CFR 151.25 (a),MARPOL (2017 cons)
Annex I Reg 17
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 18 April 2023
Resolved
For each ship subject to regulations 5 and 6 of this Annex, details of fuel oil for consumption purposes delivered to and used on board shall be recorded by means of a bunker delivery note in the form specified in appendix V and retained on board for a period of three yeas. Vessel could not provide bunker delivery notes to the marine inspector. MARPOL (2017 cons) Annex VI Reg 18.5
14 - Pollution Prevention › 146 - MARPOL Annex VI › Quality of fuel oil
Issued 18 April 2023
Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered as per MEPC.182(59) and retained for a period of not less than 12 months. The sample is to be signed by the supplier's rep and officer in charge of the bunker operation. Vessel could not provide accurate samples to inspector. MARPOL (2017 cons)
Annex VI Reg 18.8.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023
Resolved
Each cable entrance into explosionproof or flameproof equipment must be made with approved seal fittings, termination fittings, or glands that meet the requirements of 111.105–9. Marine inspector identified unapproved termination fittings at the port aft emergency shut down and the forward center lighting mast. 46 CFR 111.105-17(c)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2023
Resolved
Through runs of marine shipboard cable meeting subpart 111.60 of this part are required for all hazardous locations. Armored cable may be used to enhance ground detection capabilities. Marine inspector identified damaged electrical cable near port side containment that is powering forward center mast lights. 46 CFR 111.105-17(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2023
Resolved
Bulkheads of galleys, paint and lamp lockers, and emergency generator rooms shall be of “A” Class construction. Vessel is utilizing an unapproved container for fuel samples, paints and solvents. Vessel is to obtain an approved type flammable locker for the storage of these items. 46 CFR 32.57-10(b)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 18 April 2023
Resolved
A pressure gage shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. Port aft manifold pressure gage is missing. 46 CFR 32.50-5
08 - Alarms › N/A - No Subsystem › Boiler alarm
Issued 16 February 2021
Resolved
The audible alarm on the Thermal Fluid Heater is not operational. Operational tests and checks of all safety and limit controls must be conducted by the owner, chief engineer, or person in charge at the inspection for certification, periodic inspection, and when directed by the Officer in Charge, Marine Inspection, to determine that the control components and safety devices are functioning properly and are in satisfactory operating condition.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 31 October 2014
Resolved
Properly outfit each non rising stem valve, level operated valve, or other valve with an indicator to show whether the valve is opened or closed, IAW 46 CFR 56.20-9
Deck/Cargo › Cargo Heating › General
Issued 31 October 2014
Resolved
Prove proper operation of the thermal fluid heater, currently not being used for transfers, IAW 46 CFR 61.30-20.
Electrical › Electric Supply System (service) › Cable
Issued 31 October 2014
Resolved
Properly insulate 3 inches of exposed cable starboard side aft, IAW 46 CFR 111.60-21.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 November 2012
Resolved
Issued 835 for presence of improperly approved electrical equipment in hazardous locations, directing vessel to carry grade D and E cargoes until cargo gauging sensors are either replaced or tested in accordance with 46 CFR 111.105 (IEC 60079).
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 12 August 2011
Resolved
Effect permanent repair of .25" crack in cago tank #4 at the deep well prior to completion of ABS intermediate survey to occur late October or early November 2011.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.