Records from 2016 to 2019. Most recent: inspection, 18 December 2019.
Inspection history · 28
18 December 2019
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6862468
29 July 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6761738
5 July 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6746546
27 June 2019
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6725554
26 June 2019
In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6752668
30 May 2019
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6697365
14 December 2018
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6595339
3 August 2018
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6506539
25 July 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6563745
26 June 2018
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6464602
30 May 2018
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6429188
27 May 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6425892
24 May 2018
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6414529
25 April 2018
COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6395557
12 December 2017
COC-CVE Quarterly · ISPS II Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6322621
7 December 2017
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6320543
4 August 2017
MARPOL Annex IV Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6230691
22 May 2017
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6148590
17 May 2017
Ballast Water Examination · COC-CVE Annual · PII Safety Exam · ILO-147 Exam · ISPS II Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6148054
15 May 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6145073
6 February 2017
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6083517
17 November 2016
ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6015749
4 September 2016
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5992247
21 July 2016
In-Service Inspection · Special
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5948666
5 June 2016
Bulk Solid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5898410
3 June 2016
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5899172
16 May 2016
ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5872629
5 January 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5791834
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 December 2019
Resolved
FIRE INTEGRITY OF BULKHEADS IN SHIPS CARRYING MORE THAN 36 PASSENGERS. GALLEY ROLLER SHUTTERS FOUND NOT TO CLOSE UPON RELEASE.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 January 2020
Resolved 18 December 2019
Resolution: FPVE's observed doors closing properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 December 2019
Resolved
HEAT DETECTORS REQUIRED FOR FIRE DETECTION EQUIPMENT SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES. HEAD DETECTOR SEC.IIADD.96 FOUND INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 January 2020
Resolved 18 December 2019
Resolution: Tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2019
Resolved
THE PIPING SYSTEMS AND FITTINGS SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THEIR INTENDED SERVICE. SEWAGE TANK 5 STARBOARD HAS WASTED SEAWATER FLUSH CHECK VALVE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 10 January 2020
Resolution: LR Surveyor statement received. Valve replaced, examined and tested.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 December 2019
Resolved
EXHAUST DUCTS FROM GALLEY RANGES SHALL BE FITTED WITH REMOTE CONTROLS FOR SHUTTING OFF EXHAUST AND SUPPLY FANS, AS WELL AS PLACE FIRE DAMPERS IN THE CLOSED POSITION AT THE ENTRY DOOR. REMOTE CONTROL OUTSIDE CREW GALLEY FOUND WITH DETACHED KNOB, AND VISUAL INDICATORS NEED REPAIR ON DAMPERS FD.FS.01.1.02/2 AND FD.VE.02.2.01/2
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 January 2020
Resolved 18 December 2019
Resolution: Control repaired.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 December 2019
Resolved
TWO MEANS OF ESCAPE SHALL BE PROVIDED FROM MACHINERY SPACES. THE FOLLOWING EMERGENCY ESCAPES WERE UNABLE TO BE OPENED BY CREW AT TIME OF INSPECTION: AZIPOD ROOM PORT AND STBD SIDES, AND EMERGENCY GENERATOR ROOM.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 December 2019
Resolved 18 December 2019
Resolution: Escapes serviced and found operable.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 18 December 2019
Resolved
AN ALARM SYSTEM SHALL BE PROVIDED INDICATING ANY FAULT REQUIRING ATTENTION. AUTOMATION ALARM PANEL SHOWS "FIRE IN ENGINE ROOM," BUT THE ALARM IS NOT SHOWN ON THE FIRE CONTROL PANEL. CREW CALLS IT A "GHOST ALARM."
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 10 January 2020
Resolution: LR surveryor statement received. Alarm panel wiring corrected and panels tested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 December 2019
Resolved
THE CONSTRUCTION OF ALL DOORS IN "A" CLASS DIVISIONS WITH THE MEANS OF SECURING WHEN CLOSED SHALL PROVIDE RESISTANCE TO FIRE AND SMOKE. MULTIPLE EXTERIOR DOORS ON DECK 9 DO NOT PROVIDE RESISTANCE TO FIRE OR SMOKE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 10 January 2020
Resolution: LR statement received. Door repairs made (temporary) 14 new doors ordered for replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 June 2019
Resolved
LB # 3 gearbox failure
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2019
Resolved 25 July 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 May 2019
Resolved
74SOLAS(1997) II-2/28.1.10 - The means of escape shall be marked by lighting or photoluminescent strip indicators at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify the escape exits. Deck 7 Lido buffet on port and stbd side means of escape not visible from center of location of space.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Resolution: Vessel added photoluminescent exit signs indicating escape routes from center of space.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 May 2019
Resolved
74SOLAS(1997) II-2/33.3 - Windows facing life-saving appliances, embarkation and muster areas, external stairs and open decks used for escape routes, shall have fire integrity as required in the table in regulation 26. Where automatic dedicated sprinkler heads are provided for windows, A-0 windows may be accepted. Wajang theater deck 4 windows not indicated as meeting required A-60 boundry.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 27 June 2019
Resolution: Vessel submitted class report attesting to the validity of the fire proofing of windows facing life saving appliances.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 17 May 2017
Resolved
0750- 74 SOLAS (97) II-2/30.2 - The construction of all doors and frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as the passage of smoke and flame. Cracks and drilled holes above FSD 6.4.015 and 6.4.016 reduce the frame's resistance to the passage of smoke and flame.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 15 June 2017
Resolution: Received confirmation from Class that appropriate repairs had been completed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 November 2016
Resolved
01-0710-FIRE DOORS IN MAIN VERTICLE ZONE BULKHEADS SHALL BE SELF CLOSING. FIRE SCREEN DOORS A117 AND A069 ARE INCAPABLE OF CLOSING.- 74SOLAS(97CONS) II-2/30.4.1 - 10C
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: Deficiency Corrected on the spot.
Fire Fighting › Means of Escape › Number
Issued 17 November 2016
Resolved
02-0710-AT ALL LEVELS OF ACCOMODATION THERE SHALL BE PROVIDED AT LEAST TWO WIDELY SEPARATED MEANS OF ESCAPE. IAW MSC LETTER SERIAL NUMBER: H2-1504984, IN LIEU OF A SECOND ESCAPE, AUDIBLE DETECTORS WILL NBE PROVIDED THAT WILL BE ACTIVATED BY FIRE INCIDENT IN THE ADJACENT SPACE. THE DETECTORS PROVIDED DO NOT OPERATE IN CONJUNCTION WITH EACH OTHER AS REQUIRED. - 74SOLAS (97 CONS) II-2/45.1.1 -40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2016
Resolved 21 December 2016
Resolution: Recieved Class report attesting to the correction of the deficiency.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 16 May 2016
Resolved
01-0950-ACCUMULATOR BATTERIES SHALL BE SUITABLY HOUSED AND COMPARTMENTS USED PRIMARILY FOR THEIR ACCOMODATION SHALL BE EFFICIENTYLY VENTILATED. THERE ARE NO MEANS TO ENSURE VENTILATION HATCHES REMAIN OPEN. - 74SOLAS09CONS II-I/45.9.1. - 50C
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Lifesaving › Lifeboat › Propulsion Engine
Issued 16 May 2016
Resolved
02-0610-BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. LIFEBAOT NUMBER 3 WAS UNABLE TO START. - 74SOLAS(04) III/20.2 - 10C
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 16 May 2016
Resolution: Corrected on the spot.