BOLETTE

BOLETTE is a 2000 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2016, most recently in December 2019, along with 15 deficiencies and 1 operational control.

Records from 2016 to 2019. Most recent: inspection, 18 December 2019.

Built
2000
Last inspected
18 December 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9188037
Flag
NETHERLANDS ANTILLES
Maury page id
psix-16340

Inspections, by type

…with no type recorded6
Years with a record 4 calendar years (2016–2019)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it62735 - Convention (Subpart B), Gross Ton
31639 - Convention (Subpart B), Net Ton
33961 - Displacement, Ton
6092 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DUGAN PEARSALL Tank Barge · MISLE 937919 · 4 September 2016 · activity 5992247

Inspection history · 28

18 December 2019 COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6862468
29 July 2019 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6761738
5 July 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6746546
27 June 2019 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6725554
26 June 2019 In-Service Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6752668
30 May 2019 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6697365
14 December 2018 ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6595339
3 August 2018 Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6506539
25 July 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6563745
26 June 2018 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6464602
30 May 2018 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6429188
27 May 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6425892
24 May 2018 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6414529
25 April 2018 COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6395557
12 December 2017 COC-CVE Quarterly · ISPS II Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6322621
7 December 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6320543
4 August 2017 MARPOL Annex IV Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6230691
22 May 2017 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6148590
17 May 2017 Ballast Water Examination · COC-CVE Annual · PII Safety Exam · ILO-147 Exam · ISPS II Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6148054
15 May 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6145073
6 February 2017 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6083517
17 November 2016 ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6015749
4 September 2016 Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5992247
21 July 2016 In-Service Inspection · Special
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5948666
5 June 2016 Bulk Solid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5898410
3 June 2016 Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 5899172
16 May 2016 ISPS II Exam · COC-CVE Annual
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5872629
5 January 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5791834

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 December 2019 Resolved
FIRE INTEGRITY OF BULKHEADS IN SHIPS CARRYING MORE THAN 36 PASSENGERS. GALLEY ROLLER SHUTTERS FOUND NOT TO CLOSE UPON RELEASE.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 January 2020
Resolved 18 December 2019
Resolution: FPVE's observed doors closing properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 December 2019 Resolved
HEAT DETECTORS REQUIRED FOR FIRE DETECTION EQUIPMENT SHALL BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES. HEAD DETECTOR SEC.IIADD.96 FOUND INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 January 2020
Resolved 18 December 2019
Resolution: Tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2019 Resolved
THE PIPING SYSTEMS AND FITTINGS SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THEIR INTENDED SERVICE. SEWAGE TANK 5 STARBOARD HAS WASTED SEAWATER FLUSH CHECK VALVE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 10 January 2020
Resolution: LR Surveyor statement received. Valve replaced, examined and tested.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 December 2019 Resolved
EXHAUST DUCTS FROM GALLEY RANGES SHALL BE FITTED WITH REMOTE CONTROLS FOR SHUTTING OFF EXHAUST AND SUPPLY FANS, AS WELL AS PLACE FIRE DAMPERS IN THE CLOSED POSITION AT THE ENTRY DOOR. REMOTE CONTROL OUTSIDE CREW GALLEY FOUND WITH DETACHED KNOB, AND VISUAL INDICATORS NEED REPAIR ON DAMPERS FD.FS.01.1.02/2 AND FD.VE.02.2.01/2
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 January 2020
Resolved 18 December 2019
Resolution: Control repaired.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 18 December 2019 Resolved
TWO MEANS OF ESCAPE SHALL BE PROVIDED FROM MACHINERY SPACES. THE FOLLOWING EMERGENCY ESCAPES WERE UNABLE TO BE OPENED BY CREW AT TIME OF INSPECTION: AZIPOD ROOM PORT AND STBD SIDES, AND EMERGENCY GENERATOR ROOM.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 December 2019
Resolved 18 December 2019
Resolution: Escapes serviced and found operable.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 18 December 2019 Resolved
AN ALARM SYSTEM SHALL BE PROVIDED INDICATING ANY FAULT REQUIRING ATTENTION. AUTOMATION ALARM PANEL SHOWS "FIRE IN ENGINE ROOM," BUT THE ALARM IS NOT SHOWN ON THE FIRE CONTROL PANEL. CREW CALLS IT A "GHOST ALARM."
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 10 January 2020
Resolution: LR surveryor statement received. Alarm panel wiring corrected and panels tested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 December 2019 Resolved
THE CONSTRUCTION OF ALL DOORS IN "A" CLASS DIVISIONS WITH THE MEANS OF SECURING WHEN CLOSED SHALL PROVIDE RESISTANCE TO FIRE AND SMOKE. MULTIPLE EXTERIOR DOORS ON DECK 9 DO NOT PROVIDE RESISTANCE TO FIRE OR SMOKE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 10 January 2020
Resolution: LR statement received. Door repairs made (temporary) 14 new doors ordered for replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 June 2019 Resolved
LB # 3 gearbox failure
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2019
Resolved 25 July 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 May 2019 Resolved
74SOLAS(1997) II-2/28.1.10 - The means of escape shall be marked by lighting or photoluminescent strip indicators at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify the escape exits. Deck 7 Lido buffet on port and stbd side means of escape not visible from center of location of space.
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Resolution: Vessel added photoluminescent exit signs indicating escape routes from center of space.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 May 2019 Resolved
74SOLAS(1997) II-2/33.3 - Windows facing life-saving appliances, embarkation and muster areas, external stairs and open decks used for escape routes, shall have fire integrity as required in the table in regulation 26. Where automatic dedicated sprinkler heads are provided for windows, A-0 windows may be accepted. Wajang theater deck 4 windows not indicated as meeting required A-60 boundry.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 27 June 2019
Resolution: Vessel submitted class report attesting to the validity of the fire proofing of windows facing life saving appliances.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 17 May 2017 Resolved
0750- 74 SOLAS (97) II-2/30.2 - The construction of all doors and frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as the passage of smoke and flame. Cracks and drilled holes above FSD 6.4.015 and 6.4.016 reduce the frame's resistance to the passage of smoke and flame.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 15 June 2017
Resolution: Received confirmation from Class that appropriate repairs had been completed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 November 2016 Resolved
01-0710-FIRE DOORS IN MAIN VERTICLE ZONE BULKHEADS SHALL BE SELF CLOSING. FIRE SCREEN DOORS A117 AND A069 ARE INCAPABLE OF CLOSING.- 74SOLAS(97CONS) II-2/30.4.1 - 10C
Action required: 705 - Other - as specified
Due 17 November 2016
Resolved 17 November 2016
Resolution: Deficiency Corrected on the spot.
Fire Fighting › Means of Escape › Number
Issued 17 November 2016 Resolved
02-0710-AT ALL LEVELS OF ACCOMODATION THERE SHALL BE PROVIDED AT LEAST TWO WIDELY SEPARATED MEANS OF ESCAPE. IAW MSC LETTER SERIAL NUMBER: H2-1504984, IN LIEU OF A SECOND ESCAPE, AUDIBLE DETECTORS WILL NBE PROVIDED THAT WILL BE ACTIVATED BY FIRE INCIDENT IN THE ADJACENT SPACE. THE DETECTORS PROVIDED DO NOT OPERATE IN CONJUNCTION WITH EACH OTHER AS REQUIRED. - 74SOLAS (97 CONS) II-2/45.1.1 -40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 December 2016
Resolved 21 December 2016
Resolution: Recieved Class report attesting to the correction of the deficiency.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 16 May 2016 Resolved
01-0950-ACCUMULATOR BATTERIES SHALL BE SUITABLY HOUSED AND COMPARTMENTS USED PRIMARILY FOR THEIR ACCOMODATION SHALL BE EFFICIENTYLY VENTILATED. THERE ARE NO MEANS TO ENSURE VENTILATION HATCHES REMAIN OPEN. - 74SOLAS09CONS II-I/45.9.1. - 50C
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 3 June 2016
Lifesaving › Lifeboat › Propulsion Engine
Issued 16 May 2016 Resolved
02-0610-BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. LIFEBAOT NUMBER 3 WAS UNABLE TO START. - 74SOLAS(04) III/20.2 - 10C
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 16 May 2016
Resolution: Corrected on the spot.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.