FAIRWEATHER EXPRESS II

FAIRWEATHER EXPRESS II is a 2001 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 2001, most recently in March 2026, along with 88 deficiencies and 3 casualty investigations between 2004 and 2008.

Records from 2001 to 2026. Most recent: inspection, 7 March 2026.

Built
2001
Last inspected
7 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF6997
Flag
UNITED STATES
338647000
Maury page id
psix-26458

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (2001–2026)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)78.5 ft × 28.5 ft × 8.3 ft
Registered tonnagegross 82 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLEN MARINE INC · SITKA, AK, UNITED STATES · built 2001
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Displacement, Gross Ton
82 - Simplified, Gross Ton
65 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF6997MMSI 338647000 · active · compulsorily equipped · granted 31 December 2020, expires 23 February 2031
WDI2129MMSI 369001000 · expired · compulsorily equipped · granted 28 May 2015, cancelled 5 July 2025 · licensed under a name not among this hull’s recorded names (not shown)
WDA4700MMSI 367162000 · expired · compulsorily equipped · granted 22 May 2001, cancelled 30 April 2011
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BOLETTE Passenger (Inspected) · MISLE 16340 · 7 July 2008 · activity 3267906CHICHAGOF DREAM Passenger (Inspected) · MISLE 244276 · 7 July 2008 · activity 3267906TAKU Passenger (Inspected) · MISLE 44427 · 23 January 2004 · activity 1993056ST JUVENALY Passenger (Inspected) · MISLE 436363 · 23 January 2004 · activity 1993056

Inspection history · 54

7 March 2026 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8321258
20 August 2025 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8214725
15 May 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8136909
9 October 2023 Administrative Inspection · Plan Review "T" Boat · Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7905806
16 May 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7689747
1 February 2023 Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7630700
14 September 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7548278
19 May 2022 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7454925
17 May 2022 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7453383
15 June 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7221891
1 June 2021 Internal Structural Exam · Deficiency Check · Hull Examination · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7203136
6 May 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6947080
29 October 2019 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6848929
27 June 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6732268
10 October 2018 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6558887
17 April 2018 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6390626
3 October 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6282027
10 April 2017 Administrative Inspection · Spot Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6130004
20 April 2016 COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5852056
14 December 2015 Drydock Extension · Internal Structural Exam · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5783819
2 May 2014 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4844435
7 May 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4302050
9 December 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3996755
13 September 2010 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3849046
7 May 2009 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3469769
7 July 2008 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3267906
2 June 2008 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3225623
12 May 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3205719
1 June 2007 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2975096
18 May 2007 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2926005
7 May 2007 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2924362
9 August 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2742025
27 April 2006 COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2635184
12 April 2006 Administrative Inspection
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2623515
13 May 2005 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2359584
6 May 2005 In-Service Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2355445
7 April 2005 Hull Examination · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2327996
13 October 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2219839
4 October 2004 Administrative Inspection
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2213075
10 May 2004 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2074184
6 May 2004 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2063921
6 May 2004 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2073390
2 March 2004 Damage Survey · Examination of Repairs
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2018055
28 January 2004 Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1996010
23 January 2004 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1993056
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970886
2 June 2003 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1808205
8 May 2003 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1790091
2 May 2003 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1784342
29 March 2003 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1765069
22 May 2002 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1619729
3 May 2002 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1616624
5 October 2001 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1074495
8 May 2001 Initial Certification · Plan Review "T" Boat · Hull Examination · Initial Construction-Excluding Oversight · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1410583

Deficiency record · 88

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 May 2024 Resolved
A space containing an internal combustion engine of more than 37.3 kW (50 hp) must be equipped with a fixed gas fire extinguishing system, in compliance with 46CFR181.410. Recently installed generator set is equipped with diesel prime mover that exceeds 50hp and is installed in a space with no fixed fire extinguishing system. Provide system and installation plan for CG review and approval. 46CFR181.400(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2024
Resolved 20 June 2024
Resolution: Rectified. See documents for fireboy install details.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 May 2024 Resolved
A space containing an internal combustion engine of more than 50 hp must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76, except when a fixed-gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed. Recently installed generator set is equipped with diesel prime mover that exceeds 50hp and is installed in a space with no fixed fire extinguishing system. Provide system and installation plan for CG review and approval. 46CFR181.405(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2024
Resolved 20 June 2024
Resolution: Rectified. See documents for fireboy installation details.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 May 2024 Resolved
Repairs or alterations to the equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include, but are not limited to replacement, other than replacement in kind, of electrical wiring, and repair or alteration of fire extinguishing equipment. Recently installed electrical fire pump is not an in-kind replacement for previously installed engine driven fire pump. Provide system and installation plan, to include equipment, materials, and electrical load analysis, for CG review and approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2024
Resolved 27 February 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 May 2023 Resolved
The CO2 fire suppression system isn't installed as approved. When tested, the system does not secure the (4) engines that draw intake air from the space.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2023
Resolved 23 May 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 May 2022 Resolved
A catamaran vessel must be equipped with bilge pumps for each hull, as if each hull is a separate vessel, except where one dedicated pump is located in each hull and cross connected between each hull. Vessel's starboard hull bilge pump is inoperable. Repair bilge pump to satisfaction of attending MI prior to carrying passengers for hire. 46CFR182.520(j)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2022
Resolution: Replaced in-kind, and tested to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 June 2021 Resolved
Vessels life rafts shall be stowed in a way that permits manual release from its securing arrangements. Owner replaced the upper deck, starboard side aft 50 person IBA. The new IBA is larger than the original IBA therefore prevents the ability for the deckhands to manually release the IBA from its stowed position. Vessels total persons allowed is reduced to no more than 100.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 June 2021
Resolved 15 June 2021
Resolution: O/O extended the opening to accomidate the new size of IBA.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 4 June 2021 Resolved
Vessel's master, crew members, and persons in addition to crew in safety sensitive positions onboard must complete pre employment drug testing and be enrolled in the company's random drug testing program. Provide proof of pre employment and random drug testing for required employees.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 15 June 2021
Resolution: O/O showed that all crew was enrolled in Drug ans Alcohol testing program
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 June 2021 Resolved
Vessels fixed CO2 fire extinguishing systems in the port and starboard engine rooms and all portable extinguishers are required to be inspected and tested by a certified fire systems inspector. Vessels fixed fire systems and portable extinguisher are past due for their annual inspection. Ensure all required annual inspections and tests are completed iaw 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 15 June 2021
Resolution: C&T fire serviced fire suppression system on 09JUN21.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2021 Resolved
Vessel's exhaust systems shall be leak free. The starboard, aft, main diesel engine has an exhaust leak at the turbo charger, properly repair the exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 15 June 2021
Resolution: Exhaust leak was repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 June 2021 Resolved
Fire pump must be capable of producing 60 psi, gauge on the discharge side of the fire pump was showing only 32-38 psi. Ensure that the fire pump is capable of producing the required pressure of 60 psi.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 15 June 2021
Resolution: Fire pump was serviced and produced 60+ psi.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 4 June 2021 Resolved
Owner/operator is required to conduct an underway operational test of the vessel's hull and machinery to satisfaction of the attending CG Marine Inspector at the time of inspection and conduct emergency drills in the presence of the CG Marine Inspector. Vessel will have a new crew onboard so we were unable to complete u/w sea trials and drill during the COI inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 15 June 2021
Resolution: Conducted underway sea trials and MOB/Fire drill
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 4 June 2021 Resolved
Vessel must be in command and control by a Master with the appropriate merchant mariner credential. Vessel will be provided with a new master.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2021
Resolved 15 June 2021
Resolution: Verified attending Capt had proper credentials
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 June 2021 Resolved
Weathertight doors shall be weather tight, found the forward main deck doors, both port and starboard, gaskets were broke free from the door frame making them not weathertight. Repair or replace the door gaskets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2021
Resolved 4 June 2021
Resolution: Crew replaced the water tight gaskets port and starboard forward on the main deck, hose tested, all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 May 2020 Resolved
Replace expired hydrostatic release on EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2020
Resolution: vessel has new hydrostatic release on EPIRB
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2020 Resolved
Replace Expired Battery in Life Ring Buoy Light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2020
Resolution: Vessel has new battery installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2020 Resolved
Replace 2nd deck fwd Life Ring Buoy
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2020
Resolution: Vessel has new Ring bouy
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2020 Resolved
Replace 39 damaged Adult Lifejackets. Total Adult allowed on board is reduced to 111 until Lifejackets are replaced
Action required: 705 - Other - as specified
Resolved 21 May 2020
Resolution: Vessel has replaced 39 lifejackets
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 May 2020 Resolved
Remove or replace all expired items in both Bridge first aid kits
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2020
Resolution: Vessel has removed all expired items
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2020 Resolved
Install all engine room batteries in battery boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2020
Resolution: vessel has installed all batteries in boxs
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2020 Resolved
Install cover to prevent contacting 12 volt terminal bar in the starboard engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2020
Resolution: 12 volt terminal has been covered to prevent contact
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 May 2020 Resolved
Readjust all exhaust lagging in both engine rooms to prevent crew from contacting hot exhaust pipes.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2020
Resolution: All lagging has been adjusted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2020 Resolved
Permanent repair port aft main engine jacket water cooling line.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2020
Resolution: vessel has repaired raw water pipe all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2020 Resolved
Remove or properly terminate dead end wiring under main deck counter by the phone.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2020
Resolution: dead end wire has beeen removed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 May 2020 Resolved
Correctly label main deck first aid kit storage location
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2020
Resolution: First Aid storage location has beeen correctly marked
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2020 Resolved
Remove all plastic trash cans
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 May 2020
Resolution: all trash cans have been replaced with metal ones
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 May 2020 Resolved
Prove fire pump produces 60 PSI at pump outlet.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2020
Resolution: Fire pump tested sat
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 4 May 2012 Resolved
Install approved fire extinguisher bracket in galley
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 20 June 2012
Resolution: Operator provided proof of properly mounted fire extinguisher in galley
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 May 2012 Resolved
Properly label PFD stowage with the correct number of PFD's
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 20 June 2012
Resolution: Operator provided proof of PFD stowage locations properly marked.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 4 May 2012 Resolved
Re-install cover for echo-sounding device.
Action required: 705 - Other - as specified
Due 7 May 2012
Resolved 20 June 2012
Resolution: Operator provided proof of cover for depth sounder re-installed.
Construction/Loadline › Hull › Weld
Issued 9 December 2010 Resolved
Crack in FR 1, outboard side of port pontoon. Make repairs.
Action required: 705 - Other - as specified
Resolved 14 January 2011
Resolution: Properly welded. All sat.
Construction/Loadline › Hull › Side Shell
Issued 9 December 2010 Resolved
Crack in FR 4, ouboard port side pontoon.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2011
Resolution: Properly welded. All sat.
Construction/Loadline › Hull › Weld
Issued 9 December 2010 Resolved
Weld suckback on insert port side in fwd compartment. Make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2011
Resolution: Properly welded. All sat.
Construction/Loadline › Hull › Weld
Issued 9 December 2010 Resolved
Weld suckback on insert stbd side in fwd compartment. Make repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2011
Resolution: Properly welded. All sat.
Construction/Loadline › Hull › Hull Plating
Issued 27 September 2010 Resolved
Crop & renew temporary repaired fractured shell plating above Port Exhaust Main Engine on the inboard Port pontoon and STBD pontoon, inboard side IVO aft exhaust.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2011
Resolved 21 April 2011
Construction/Loadline › Hull › Transverse Frame
Issued 14 January 2010 Resolved
Crack discovered on frame in the stbd pontoon, fwd compartment. Crack must have developed while sitting on drydock. Complete repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2011
Resolution: Crack was cleaned and welded. All sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 May 2009 Resolved
Provide annual servicing report.
Action required: 705 - Other - as specified
Due 11 June 2009
Resolved 17 May 2009
Resolution: Completed.
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2008 Resolved
Vessel is experiencing intermittent loss of power on it aux generator. Make permanent repairs to the aux generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 13 July 2008
Resolution: Secured loose relays.
Engineering › Bilge Water Management System › Pump
Issued 12 May 2008 Resolved
Starboard bilge pump was not operating. Need to provide proper operation of the starboard bilge pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 27 May 2008
Engineering › Sea-water System (primary cooling) › Pump
Issued 12 May 2008 Resolved
Provide proper operation of the port forward main raw water pump impeller.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 27 May 2008
Communications › Radio Communications › EPIRB
Issued 12 May 2008 Resolved
Need to provide proper registration/documentation of EPRIB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 23 May 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 May 2008 Resolved
Need to demonstrate fire and abandoned ship drills to the satisfaction of a Coast Guard Inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 23 May 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 May 2008 Resolved
Need to properly stencil lifebuoys with vessels name and hailing port.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 27 May 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 May 2008 Resolved
Need to properly mount/secure microwave in galley.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 27 May 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 May 2008 Resolved
Need to remove adult lifejacket sign in foward compartment space, due to no lifejackets in the space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 27 May 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 May 2008 Resolved
Provide proper operation of the DC-volts meter at the operating station.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 27 May 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 May 2007 Resolved
Properly mark child lifejacket quantity and adult lifejacket quantity in forward stowage cabinet lower deck. Seperate child lifejackets from adult lifejackets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 18 May 2007
Resolution: Item fixed on the spot.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 18 May 2007 Resolved
Hydrostatic release for EPIRB not marked with expiration date. Replace hydrostatic release for EPIRB or verify date of installation/period of service of existing hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2007
Resolution: Call from master of the vessel [name withheld] attesting to purchase of new hydrostatic release.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 May 2007 Resolved
Ensure proper 6 year internal inspection and annual service of portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2007
Resolution: Items replaced on the spot.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 18 May 2007 Resolved
Excessive oil in bilges. Clean bilges of excessive oil.
Due 18 May 2007
Resolved 18 May 2007
Resolution: Bilges cleaned prior to Inspector departure from Gustavus.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 April 2006 Resolved
Renew & install a new CO2 time-delay (30 second delay) in the Port Side E/R. Test time-delay to the satisfaction of an attending marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 9 August 2006
Resolution: Done. sat.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 27 April 2006 Resolved
Secure for sea the two Fridge in the galley area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 9 August 2006
Resolution: Done, sat.
Engineering › Steering Gear System › Linkage
Issued 27 April 2006 Resolved
Install double nut to the Port & Starboard steering linkage indicator & bucket assembly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 9 August 2006
Resolution: Done, sat.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 April 2006 Resolved
Provide missing "May-Day" placard in the bridge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 9 August 2006
Resolution: Done ... Fax sends by [name withheld]
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 April 2006 Resolved
Provide a CG Approved First Aid Kit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 9 August 2006
Resolution: Done, sat. by [name withheld]
Fire Fighting › Means of Escape › Blocked
Issued 27 April 2006 Resolved
Clear emergency exit located STBD storeroom.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 3 May 2006
Resolution: Done
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 April 2006 Resolved
Start a lifesaving equipment & maintenance record.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 3 May 2006
Resolution: Done
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 April 2006 Resolved
Re-write vessel’s name on the ring buoys.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 3 May 2006
Resolution: Done
Communications › Radio Communications › EPIRB
Issued 27 April 2006 Resolved
Re-register vessel's EPIRB with NOAA.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2006
Resolved 3 May 2006
Resolution: Done
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 13 May 2005 Resolved
Re-weld fracture on foundation railing by the passenger boarding ramp. Existing rails temporary holder by aluminum metal & screws.
Condition: Damaged By Earlier Event
Due 13 May 2005
Resolved 13 May 2005
Resolution: [name withheld], port captain, had arranged for [name withheld], C/E, to re-weld rails. Company had welder on dock inside the small workshop for light maintenance, sat.
Construction/Loadline › Hull › Side Shell
Issued 7 April 2005 Resolved
Crop and renew port hull sideshell on outboard side at transom area approx. 18"x18".
Action required: 705 - Other - as specified
Resolved 10 April 2005
Construction/Loadline › Hull › Side Shell
Issued 7 April 2005 Resolved
Crop and renew stbd hull sideshell on outboard side at transom area approx. 12"x18" and deck under cleat area approx 12"x18" in same location .
Action required: 705 - Other - as specified
Resolved 9 April 2005
Engineering › Bilge Water Management System › Valve
Issued 7 April 2005 Resolved
Provide reach rods for both bilge valves at collision bulkhead.
Action required: 705 - Other - as specified
Resolved 9 April 2005
Construction/Loadline › Hull › Bottom Plating
Issued 7 April 2005 Resolved
In port bow V & weld inboard "step" where marked.
Action required: 705 - Other - as specified
Resolved 10 April 2005
Construction/Loadline › Hull › Side Shell
Issued 7 April 2005 Resolved
Crop and renew 18"x18" area in stbd void 2, in way of inset that is hidden by "Bondo".
Action required: 705 - Other - as specified
Resolved 10 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 April 2005 Resolved
Make repairs to aft walkway over outboard drive shaft in port side engine room where aft outboard attachment is fractured.
Action required: 705 - Other - as specified
Resolved 11 April 2005
Lifesaving › Hand Flares › Quantity
Issued 10 May 2004 Resolved
Vsl had 3 required day flares expired. Required vsl to replace flares.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 10 May 2004
Resolution: Vsl replaced expired flares with current up to date flares.
Electrical › Lighting (service)
Issued 6 May 2004 Resolved
Electrical wire in storage area at fwd part of house on main deck had open unprotected end. Required master remove wire or mount in electrical junction box. LEGACY COMPONENT DESC: Lighting Feeder
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2004
Resolved 10 May 2004
Resolution: Corrected on the spot
Navigation › Piloting/Steering
Issued 6 May 2004 Resolved
Vsl was missing current light list. Required vsl to obtain a current copy. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 7 May 2004
Resolution: Master purchased updated copy of Coast Guard Light List.
Navigation › Piloting/Steering
Issued 6 May 2004 Resolved
Vsl missing Tidal Current Tables. Required vsl to obtain recent version. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 7 May 2004
Resolution: Master purchased current version of Tidal Current Tables.
Navigation › Piloting/Steering
Issued 6 May 2004 Resolved
Vsl was missing current US Coast Pilot. Required vsl to obtain a current copy. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 7 May 2004
Resolution: Master purchased current US Coast Pilot for vsl.
Accommodation/Occupational Safety › Heating
Issued 2 March 2004 Resolved
Installed without CG oversight or plan review: Remove the Oil Fired heater (Monitor Stove) from the passenger space along with removing the associated 55 Gallon drum of #2 diesel and fuel supply from the main deck. Insert and re-weld the holes for the air-intake/exhaust and fuel supply. LEGACY COMPONENT DESC: Fuel Containers/Tanks
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2004
Resolved 19 April 2004
Resolution: Partially resolved. The penetration approx. 3 ft. off of the deck near the forward port main cabin door is temporarily patched.
Accommodation/Occupational Safety › Heating
Issued 2 March 2004 Resolved
Installed without CG oversight or plan review: Remove the improperly installed electric forced air heaters and 220v electrical supply from the passenger space. Heaters have warning label not to install within three ft. of combustibles and are in direct contact with seats & lifejackets. LEGACY COMPONENT DESC: Electric Air Heating Equipment
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2004
Resolved 19 April 2004
Resolution: Heaters removed, suitable heaters to be identified and presented to the CG for approval.
Electrical › Lighting (service)
Issued 2 March 2004 Resolved
Installed without CG oversight or plan review: Diner lighting circuit appears adequate but, lights are tapped into the feed cables with automotive type "piercing blade" connectors Replace with UL crimp connectors. Lighting is not to be used until electrical plans have been submitted & approved. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2004
Resolved 19 April 2004
Resolution: System removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2004 Resolved
Remove extension cord run through the port vent to the fuel tank space used as "Shore Power". And rewire the Tank Tender using UL Marine or Boat Cable and submit plans for approval of system.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2004
Resolved 19 April 2004
Resolution: Partially completed: extension cords and extension cord serving as wiring for tank tender has been removed. Tank tender pends rewiring and plan submittal
Operations/Management › Navigation Safety
Issued 28 January 2004 Resolved
Proceed to Sitka, AK & complete permanent repairs to hull fracture & deckhouse windows: (a) master's discretion to get underway under reasonable sea conditions, (b) no passengers for hire, (c) master to check temp repairs bilge keel fractures once underway, & (c) notify CG MSD Sitka upon arrival. LEGACY COMPONENT DESC: Navigation Underway, General
Condition: Damaged By Earlier Event
Due 28 February 2004
Resolved 6 May 2004
Resolution: done
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 May 2003 Resolved
Complete servicing of CO2 fixed fire fighting systems, to include tests of time delays, alarms, local and remote releases, and automatic shutdowns.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2003
Resolved 2 June 2003
Communications › Alarms/Indicators
Issued 2 May 2003 Resolved
Toubleshoot and prove proper operation of audible bilge alarm in wheelhouse. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 2 June 2003
Communications › Internal Communications System
Issued 2 May 2003 Resolved
Demonstrate operation of intercom and public address systems at all installed locations.
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 2 June 2003
Communications › Radio Communications
Issued 2 May 2003 Resolved
Replace hydrostatic release for EPIRB and document monthly test. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 2 June 2003
Operations/Management › Passenger Operations
Issued 2 May 2003 Resolved
Provide a passenger and crew count to the Haines base of operations prior to every underway voyage per 46 CFR 185.504.
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 2 June 2003
Navigation › Piloting/Steering
Issued 2 May 2003 Resolved
Provide current tidal current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 2 June 2003
Electrical › Electrical Distribution System (service)
Issued 2 May 2003 Resolved
Enclose or provide insulating boots for all ungrounded terminals of the sewage transfer pump solenoid. LEGACY COMPONENT DESC: Conductor
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 2 June 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 2 May 2003 Resolved
Provide documentation of work performed during servicing of CO2 fixed firefighting systems.
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 8 May 2003
Resolution: Sighted report, which showed incomplete servicing. Issued new req''t to complete servicing.
Operations/Management › Drug and Alcohol Testing
Issued 2 May 2003 Resolved
Provide documentation of the latest Management Information System Requirements (MIS) report sent to the Coast Guard (G-MOA). LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 2 June 2003
Lifesaving
Issued 3 May 2002 Resolved
Provide category I EPIRB, registered and mounted appropriately prior to carrying passengers. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2002
Resolution: Cleared deficiency based upon verbal report by Master that EPIRB has been installed and registered.
Documentation
Issued 8 May 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 June 2001
Resolved 15 June 2001
Documentation
Issued 8 May 2001 Resolved
Vessel shall not be placed into passenger carrying serivce until an approved stability letter is issued by the USCG Marine Safety Center and posted under glass or other transparent materials such that all pages are visible, at the operating station of the vessel IAW 46 CFR 176.306.
Condition: Unknown
Due 8 June 2001
Resolved 15 June 2001
Lifesaving
Issued 8 May 2001 Resolved
Vessel shall not be placed into passenger carrying service until crew training (46 CFR 185.420), abandon ship and person overboard drills and training (46 CFR 185.520), and firefighting drills and training (46 CFR 185.524) are conducted.
Condition: Unknown
Due 8 June 2001
Resolved 15 June 2001

Casualty record · 3

23 January 2004Routine · role: Involved in a Marine Casualty · activity 1993056
1 June 2007Routine · role: Involved in a Marine Casualty · activity 2975096
7 July 2008Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · activity 3267906
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.