Records from 2004 to 2026. Most recent: inspection, 2 April 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
1)FWD STBD engine leak on exhaust raw water cooling line.
2)FWD STBD raw water suction pump has water leak Ivo gasket and pump.
2)AFT STBD exhaust water flexible hose is not properly secured/supported.
3) AFT PORT exhaust flex hose is not double clamped.
4) All engines lug covers missing on starters
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2026
Resolution: Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2026
Resolved
(a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: Both audible and visual high level alarms not working for port fuel space.
46 CFR 182.115(D)
Action required: 10 - Deficiency Rectified
Resolved 2 April 2026
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2025
Resolved
(c) S and L. All piping, valves, and fittings shall be
in accordance with good marine practice and suitable
for the purpose intended.
Upper deck hose station piping is leaking somewhere in the overhead and needs to be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 14 May 2025
Resolution: Installed new 90 degree elbo where leak was identified. All sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2025
Resolved
(b) Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
#2 MDE lubricating oil pressure gauge is not operational, replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 28 May 2025
Resolution: pressure gauge was replaced and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2025
Resolved
(b)(4) Shutoff valves, installed so as to close against the
fuel flow, must be fitted in the fuel supply lines, one at
the tank connection and one at the engine end of the fuel
line to stop fuel flow when servicing accessories shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
Emergency fuel shutoff on port side fuel tank does not seat closed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 14 May 2025
Resolution: Fuel shutoff valve closes completely.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 May 2025
Resolved
(a) At each inspection for certification and at every other
vessel inspection all observed unsafe practices, fire
hazards, and other hazardous situations must be
corrected and all required guards and protective devices
must be in satisfactory condition.
Refrigerator needs to be removed or secured for sea. If refrigerator remains onboard, a new power outlet must be installed to eliminate the need for an extension cord.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2025
Resolved 28 May 2025
Resolution: Refrigerator has been properly secured and properly wired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 April 2024
Resolved
The manufacturer's instructions for onboard maintenance of survival craft must be onboard a vessel of more than 65'. The cognizant OCMI may accept, instead of the instructions required above, a shipboard planned maintenance program. Manufacturer's instructions were not onboard the vessel. Provide copy of instructions or develop shipboard maintenance program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 19 April 2024
Resolution: Survival craft maintenance instructed provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 April 2024
Resolved
The following tests and inspections must be carried out weekly on a vessel: each survival craft must be visually inspected to ensure its readiness for use. Survival craft inspections are currently being conducted every other week. Amend safety equipment log to add weekly survival craft inspections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 19 April 2024
Resolution: Weekly survival craft inspection added.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Two of three provided charts were from 2023. Provide up-to-date charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 19 April 2024
Resolution: Up to date charts added.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2024
Resolved
Repair or replace 06 [name withheld] lifejackets with tears/damage. Passenger count reduced to 144 until effective repairs are made or lifejackets are replaced.
Action required: 705 - Other - as specified
Resolved 1 August 2024
Resolution: Lifejackets replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 April 2024
Resolved
Each survival craft on a vessel must be inspected monthly. The master of the vessel shall ensure that each EPIRB must be tested monthly. Inspections shall be logged or otherwise documented for review. JUN and OCT2023 liferaft inspections were not completed. JUN, AUG-OCT2023 EPIRB tests were not logged.
Action required: 10 - Deficiency Rectified
Resolved 5 April 2024
Resolution: Educated Captain on required log entries.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 5 April 2024
Resolved
Flexible hose runs must be visible, easily accessible, protected from machinery... Flexible fuel lines in contact with sharp edges throughout port engine room missing chaffing gear to prevent damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 19 April 2024
Resolution: Chaffing gear added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Repair port aft main diesel engine oil leak in way of water pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 19 April 2024
Resolution: Oil leak secured; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2024
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Secure electrical cables in overhead of port engine room with fallen/loose supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 19 April 2024
Resolution: supports added; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 April 2024
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Wheelhouse exhaust temperature gauges are inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2024
Resolved 19 April 2024
Resolution: Gauges repaired; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 May 2022
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment otherthan small buoyancy compartments, under all practical conditions. Starboard side bilge pump was not draining the port forepeak space during testing.
46 CFR 182.25-10 (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Bilge manifold repaired and tested SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 May 2022
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. Fire pump was leaking excessively at the pump and just aft of the strainer.
46 CFR 181.15-5(c) (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Fire pump repairs made and tested SAT.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 May 2022
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Emergency fuel shut off cables are ran through a hole in the deck which is causing corrosion from dissimilar metals and chaffing the cable.
46 CFR 176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Proper deck penetrations made for fuel shut off cables.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 May 2022
Resolved
Rules in this subpart (Rules 20-31) (§§ 83.20 through 83.31) shall be complied with in all weathers. Stern light was inoperable.
33 CFR 83.20 (Rule 20)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Stern light bulb replaced and tested SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 May 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Portable lights were missing at operating station and both engine spaces.
46 CFR 183.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Portable lights replaced at operating station and both E/R's
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 May 2022
Resolved
(a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Electronic charts were not updated.
46 CFR 184.420(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2022
Resolution: Electronic chartss updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2021
Resolved
An adult lifejacket must be provided for each person carried on board a vessel. Replace the 25 unserviceable lifejackets with new lifejackets. Passenger count reduced by amount of lifejackets missing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2021
Resolution: 25 new lifejackets were replaced.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 23 June 2021
Resolved
When operating a vessel on a body of water where discharge of sewage is prohibited, the operator must secure each device. Provide locking device for each MSD overboard discharge valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2021
Resolution: Locking device installed on MSD discharge valve
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2021
Resolved
All electrical equipment and circuits must be clearly marked and identified. Label all circuit breakers on aft galley wall.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Circuit breakers were labeled.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 June 2021
Resolved
Drills and training shall be logged or otherwise documented for review by USCG upon request. Provide log for 2021 to record drills and training.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Logbook created for 2021.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 June 2021
Resolved
Vessel must carry up to date light list, tide tables, Coast Pilot. Current electronic version of pubs not available on vessel computer in bridge. Provide electronic or hard copy of light list, tides and Coast Pilot.
Action required: 10 - Deficiency Rectified
Resolved 23 June 2021
Resolution: Up to date copies of publications provided on vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 March 2020
Resolved
Conduct Man Overboard and Fire Drills to the satisfaction of an attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2020
Resolved 19 June 2020
Resolution: Witnessed satisfactory drills.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2020
Resolved
Install Coffee pot or properly terminate wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 16 June 2020
Resolution: Wires properly terminated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2020
Resolved
Install head flush regulators in proper junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 16 June 2020
Resolution: Properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2020
Resolved
Make permanent repairs to oil leak on #1 MDE near oil filters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 16 June 2020
Resolution: Witnessed satisfactory operation with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020
Resolved
Make permanent repairs to #1 MDE fuel leak at manifold.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2020
Resolved 16 June 2020
Resolution: Witnessed satisfactory operation with no leaks noted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 March 2020
Resolved
Install missing lagging on #1,2&4 MDE exhaust.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 16 June 2020
Resolution: All lagging properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 9 March 2020
Resolved
Install guarding on drive line penetrations in aft E/R bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 16 June 2020
Resolution: Guards properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020
Resolved
Repair leaking coolant in #3 MDE aft head gasket.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2020
Resolved 16 June 2020
Resolution: Witnessed satisfactory operation with no leaks noted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 March 2020
Resolved
Install seal on deck hatch for STBD jet room.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2020
Resolved 19 June 2020
Resolution: New seal installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2020
Resolved
Make permanent repairs to broken water pump below generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2020
Resolved 16 June 2020
Resolution: Pump properly mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 March 2020
Resolved
Install 6 man raft. (missing)
Action required: 10 - Deficiency Rectified
Due 9 March 2020
Resolved 9 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 March 2020
Resolved
Properly secure IBAs with hydrostatic release.
Action required: 10 - Deficiency Rectified
Due 9 March 2020
Resolved 9 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2020
Resolved
Properly repair port bilge pump cover.
Action required: 10 - Deficiency Rectified
Due 9 March 2020
Resolved 9 March 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2020
Resolved
Properly secure overhead wiring in generator room.
Action required: 10 - Deficiency Rectified
Due 9 March 2020
Resolved 9 March 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2020
Resolved
Provide junction box cover for port E/R ventilation power.
Action required: 10 - Deficiency Rectified
Due 9 March 2020
Resolved 9 March 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 March 2020
Resolved
Replace weather tight seal on port fwd main cabin door.
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 March 2020
Resolved
Secure microwave for heavy seas ovens.
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2020
Resolved
Include quantity for upper deck cabin life jacket storage.
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 March 2020
Resolved
Remove CO2 fire signs and procedures from wheel house, vessel does not have a fixed CO2 system on board.
Action required: 10 - Deficiency Rectified
Due 10 March 2020
Resolved 10 March 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 January 2020
Resolved
Plastic through-hull fittings found throughout vessel. Remove and replace with metallic through hull fittings.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2020
Resolved 6 February 2020
Resolution: Plastic through hull fitting removed and replaced with aluminum through hull fittings or blanked off with aluminum inserts welded in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 January 2020
Resolved
Prove proper operation of Port Forward MDE.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2020
Resolved 9 March 2020
Resolution: Proper operation witnessed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 September 2019
Resolved
Repair exhuast leak on fwd starboard Main.
Action required: 10 - Deficiency Rectified
Resolved 25 September 2019
Resolution: Crew and mechanic replaced exhaust gasket and repaired the leak.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 September 2019
Resolved
Vessel captain and crew were not familiar with the fire suppression system and how it operated. The crew was also logging that they've checked the FM200 fire system when the vessel does not have this equipment.
Action required: 30 - Ship detained
Resolved 12 September 2019
Resolution: Crew was trained by company port captain on proper operation of all types of systems and informed as to what type of system the vessel has and how to record N/A in logbooks if no system is there.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Exhaust leaks exist on all engines of the vessel. The port machinery space is covered in black carbon dust from the exhaust.
Action required: 30 - Ship detained
Resolved 12 September 2019
Resolution: All exhaust systems were tightened and gaskets replaced as necessary.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2019
Resolved
Fuel is leaking from the starboard aft engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2019
Resolution: Fuel leak was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2019
Resolved
Generator has a fuel leak on the fuel filter system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2019
Resolution: Leaks were repaired.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 September 2019
Resolved
Oil and fuel have accumulated in both machinery spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2019
Resolution: Bilges were cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 September 2019
Resolved
Oil, cooling water, and exhaust jacket water, are all leaking from the generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2019
Resolution: Leaks were repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2019
Resolved
Replace or repair 21 adult life jackets total adult persons count is reduced to 135 until cleared.
Action required: 705 - Other - as specified
Resolved 2 May 2019
Resolution: Vessel has replaced 21 adult lifejacket bringing the total back to 156. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 March 2019
Resolved
Post stability letter so that all pages are visibile from operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2019
Resolution: Vessel has corretly posted stability leter
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 March 2019
Resolved
Repair or replace 06 lifejackets with tears in cover and add retro to 06 lifejackets with damaged retroreflective tape prior to carrying more than 144 persons.
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: this def was cleared and added to the new one that was issued
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 13 March 2019
Resolved
Repair holes in engine room fan trunks above main deck at next scheduled drydock.
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 9 March 2020
Resolution: Wasted area cropped and renewed
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 13 March 2019
Resolved
Repair holes in bulkhead to restore watertight integrity by permanent means by next scheduled drydock.
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 9 March 2020
Resolution: Wasted area cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2019
Resolved
Repair leak in piping at forward end of port jet room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2019
Resolution: pipping has been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 March 2019
Resolved
Install 6-person IBA prior to carrying greater than 150 persons.
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Vessel has installed 6 man IBA
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 March 2019
Resolved
Repair starboard #3 void bilge high level alarm to announce audibly at operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2019
Resolution: High level bilge alarm has been repaired
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 6 February 2018
Resolved
Ensure all required fire extinguishers are serviced and provided.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified all extinguishers were Present, properly distibuted, and serviced.
Engineering › Bilge Water Management System › Pump
Issued 6 February 2018
Resolved
Prove proper operation of the installed bilge pumping system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 27 February 2018
Resolution: Witnessed an operational test of the bilge system; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2018
Resolved
Renew battery on vessel's ring buoy light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified the battery was renewed and the proper function of the light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 February 2018
Resolved
Provide an approved first aid kit.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified that an adequately supplied first aid kit was aboard.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 6 February 2018
Resolved
Provide up-to-date charts, tide tables, and current tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified the presence of up-to-date charts and tables.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 February 2018
Resolved
Readjust and demonstrate proper operation of the remote fuel oil stop for the port tank.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Witnessed an operational test of the port fuel oil tank remote fuel stop; all sat.
Fire Fighting › Fire Pumps › Pressure
Issued 6 February 2018
Resolved
Prove proper operation of fire pump discharge pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified the proper installation and operation of the fire pump discharge pressure gauge.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 February 2018
Resolved
Display an up-to-date Certification Expiration Date Sticker (SPV Decal)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified up-to-date SPV decals were displayed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 February 2018
Resolved
Conduct underway drills prior to commencing seasonal operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 4 May 2018
Resolution: Conducted underway drills, all sat
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 January 2018
Resolved
Prove repairs of the 1.5" sched 80 through hull penetration in the #3 STBD Void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 24 January 2018
Resolution: Verified installation of new through hull fitting with schedule 80 pipe with new shop fabricated flange from 3/4" aluminum plate. 3 gussets provided for support.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 January 2018
Resolved
Remove accumulation of fallen insulation/rubbish from the port engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 27 February 2018
Resolution: Verified that all rubbish was adequately removed from the port engine room.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 March 2017
Resolved
Properly maintain, calibrate, & train personnel on use of onboard alcohol test equipment or have approved test strips onboard the vessel.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 3 May 2017
Resolution: Vsl has alcohol test strips onboard.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 21 March 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 3 May 2017
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 21 March 2017
Resolved
Properly secure vessels IBA's in a float free arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2017
Resolved 3 May 2017
Resolution: Vsl's IBA's properly installed the vsl.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 21 March 2017
Resolved
Properly secure refrigerators and small galley equipment in the snack bar area.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 3 May 2017
Resolution: Small appliances have been properly secured.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 21 March 2017
Resolved
Properly label all lifejacket storage containers and lockers adult or child lifejacket with the quantity stored in each container / cabinet.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 3 May 2017
Resolution: New placards made and installed for lifejacket stowage locations.
Personnel › Training › Passenger Safety
Issued 21 March 2017
Resolved
Conduct u/w emergency drills in the presence of the CG Marine Inspector.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 3 May 2017
Resolution: Conducted u/w emergency drills onboard this vessel with five crews total. Drills and u/w sea trail of vessel - All SAT.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 26 May 2016
Resolved
Properly repair the starboard forward No.4 MDE which has damaged cylinder head and turbo charger.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2016
Resolved 26 May 2016
Resolution: Company mechanics completed a top end overhaul and replaced the faulty turbo charger with a new one tested - SAT.
Operations/Management › Drills/Instruction › Fire
Issued 19 April 2016
Resolved
Demonstrate safety drills, fire-abandon-MOB drills, prior to carry pax at the presence of an attending marine inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 5 May 2016
Resolution: Drills were conducted with all crews from Allen Marine.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 April 2016
Resolved
Label lifejacket stowage located forward lower Pax accomodation area.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 29 April 2016
Resolution: lifejacket storage marked
Construction/Loadline › Hull › Weld
Issued 19 April 2016
Resolved
Re-weld fracture (2 cracks) located forward portside bow above the waterline.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 29 April 2016
Resolution: Cracks Gouged and Rewelded.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 April 2016
Resolved
Re-weld small fracture located STBD machinery space forward main engine exhaust stiffener lower bilges outboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 5 May 2016
Resolution: Stiffener rewelded.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 19 April 2016
Resolved
Properly repair forward No. 1 main engine exhaust - flanged weld disconnected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 5 May 2016
Resolution: Entire Exhaust piping replaced as new.
Fire Fighting › Fire Hydrants › Condition
Issued 19 April 2016
Resolved
Perform fire nozzle maintenance. Demonstrate nozzle close completely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 29 April 2016
Resolution: nozzles fixed