MAURY USCG vessel records
← All vessels

DOTTIE

Built
2001
Last inspected
19 May 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 19 May 2026
…with no type recorded25
Operational controls None recorded without a removal date
Years with a record 25 calendar years (2001–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
3685 - Convention (Subpart B), Gross Ton 2274 - Convention (Subpart B), Net Ton 7417 - Dead Weight, Ton 9074 - Displacement, Ton
Maury page id
psix-23241
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

PACIFIC FALCON Towing Vessel · MISLE 91950 · 8 June 2020 · activity 6971572BRIAN S Towing Vessel · MISLE 83115 · 3 February 2010 · activity 3679278JAMES T QUIGG Towing Vessel · MISLE 112913 · 3 February 2010 · activity 3679278ERNEST CAMPBELL Towing Vessel · MISLE 101698 · 11 October 2003 · activity 1928392

Inspection history · 59

19 May 2026 MARPOL Annex I Examination · Vessel Attendance · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8357647
6 April 2026 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8326702
26 March 2026 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8314724
3 March 2026 Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8308962
13 May 2025 Annual Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8133633
16 January 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7848925
22 August 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7774902
24 February 2023 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7651080
8 April 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7427436
15 February 2021 Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134321
26 January 2021 Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7131063
24 June 2020 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6986063
8 June 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6971572
28 May 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6963117
27 March 2019 Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6644471
11 August 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6508173
18 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6535065
31 May 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6160675
21 August 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5979031
16 July 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5942715
1 March 2016 Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5824855
4 July 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5173735
15 May 2015 Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5109362
9 May 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5121422
25 October 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5012005
14 June 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4888503
4 May 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4850397
12 April 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4834694
5 April 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4830414
20 March 2014 MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4817880
23 September 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4448204
25 May 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4321740
26 March 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4275656
28 August 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4129058
22 July 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4090841
26 June 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4091454
27 November 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3899460
25 June 2010 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3780615
3 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3679278
29 April 2009 MTSA Verification · Internal Structural Exam · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3467273
11 June 2008 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3234278
18 July 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3013269
13 May 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2932027
4 April 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2901923
21 February 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2875037
27 June 2006 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2693458
3 June 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2670823
13 May 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2649686
28 April 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2627393
15 December 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2552596
26 May 2005 MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2375805
26 July 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2145529
8 July 2004 Internal Structural Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2126347
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957808
11 October 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1928392
16 September 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1902736
11 July 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1646644
10 July 2001 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389432
2 July 2001 Hull Examination · Construction Oversight · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1379546

Deficiency record · 17

01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 19 May 2026 Resolved
Each marine diesel engine with a power output of more than 130 kW installed on a ship shall comply with this regulation. For those engines which have not been adjusted or modified relative to the original specification of the manufacturer, the provision of a valid EIAPP Certificate should suffice to demonstrate compliance with the applicable NOx limits. Vessel's keel laid date and diesel engine power output require an EIAPP certificate for the two diesel engines for the cargo pumps. No evidence of valid EIAPP certificates for these engines was available at the time of the inspection.
Action required: 702 - Prior to embarking on international voyage
Resolved 5 June 2026
Resolution: Received required documentation. See narrative.
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 13 May 2025 Resolved
Each marine diesel engine with a power output of more than 130 kW installed on a ship shall comply with this regulation. For those engines which have not been adjusted or modified relative to the original specification of the manufacturer, the provision of a valid EIAPP Certificate should suffice to demonstrate compliance with the applicable NOx limits. Vessel's keel laid date and diesel engine power output require an EIAPP certificate for each diesel engine. No evidence of valid EIAPP certificates for these engines were available at the time of the inspection.
Action required: 705 - Other - as specified
Due 13 June 2025
Resolved 19 May 2026
Resolution: Re-issued new deficiency, see A/N: 8357647
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 January 2024 Resolved
If, during an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Crack in collision bulkhead between forward rake and void #1 identified allowing cargo to leak into double hull. 46 CFR 31.10-21(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2024
Resolved 31 January 2024
Resolution: Crack repaired with 18x18 insert.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 January 2024 Resolved
On all tank vessels, the construction or conversion of which is started on or after November 10, 1936, the cargo pumps shall be designed and installed to minimize the danger of sparking. Gaskets on both cargo pump shafts leading into machinery space bulkhead deteriorated. 46 CFR 32.50-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2024
Resolved 31 January 2024
Resolution: Both gaskets replaced.
Deck/Cargo › Cargo Heating › General
Issued 31 May 2017 Resolved
During testing of draft air limit control on TFH, shut down and alarm failed to function. Damper linkage appeared bent and did not operate smoothly. Draft controls cycled continuously. Prove proper operation of draft air loss limit control and provide tech report on draft air controls.
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 20 July 2017
Resolution: Received tech report indicating problems corrected.
Deck/Cargo › Cargo Heating › General
Issued 31 May 2017 Resolved
When tested all thermal fluid heater safety limit control alarm indication were for Low Low Water Cut Out (LLWCO) regardless of system tested. Make alarm indications match safety limit control tested and prove porper operation to attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 12 July 2017
Resolution: Alarms indicated correct system trips.
Construction/Loadline › Structures › Deck Plating
Issued 20 March 2014 Resolved
Repair pinhole leak in #1 starboard cargo tank, in way of adjacent void, one swash bulkhead to starboard of centerline.
Due 21 March 2014
Resolved 21 March 2014
Engineering › Fuel Oil Service System › Hose
Issued 20 March 2014 Resolved
Provide flame sleeve or replace thermal fluid heater fuel oil supply hose.
Due 21 March 2014
Resolved 21 March 2014
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 July 2004 Resolved
Repair leak #1P cargo tank bottom @ 8" crack in weld, @ 15' from aft bulkhead, @ 1' inbd from centerline.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2004
Resolved 10 July 2004
Resolution: Repaired satisfactorily.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 July 2004 Resolved
Repair pinhole leak #3S cargo tank bottom, @ 6' aft of fwd bulkhead, @ 4th frame from starboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2004
Resolved 10 July 2004
Resolution: Repaired satisfactorily.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 11 July 2002 Resolved
Provide proper operation of thermal fluid heater.
Due 15 July 2002
Resolved 12 July 2002
Resolution: Conducted proper operating test.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 11 July 2002 Resolved
Provide documentation to prove annual check for accuracy on cargo pump discharge gauges. LEGACY COMPONENT DESC: Piping
Due 19 July 2002
Resolved 17 July 2002
Resolution: Proper documentation was provided.
Navigation
Issued 2 July 2001 Resolved
Provide functional approved navigation lights prior to sailing. COLREGS.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Deck/Cargo
Issued 2 July 2001 Resolved
Provide proper painting and labeling of vapor recovery system prior to performing cargo operations requiring vapor recovery. 46 CFR 39.20-1.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Deck/Cargo
Issued 2 July 2001 Resolved
Provide discharge removal equipment and pollution prevention equipment prior to carrying cargo. 33 CFR 155.210.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Documentation
Issued 2 July 2001 Resolved
Provide valid loadline certificate and stability letter prior to sailing. 46 CFR 31.25-1 and 46 CFR 31.10-30.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Documentation
Issued 2 July 2001 Resolved
Provide approved SOPEP and transfer procedures prior to carrying cargo. MARPOL and 33 CFR 155.72.
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.