Records from 2007 to 2026. Most recent: inspection, 28 April 2026.
Documentation record
Registered dimensions (L × B × D)381.3 ft × 74.0 ft × 25.0 ft
Registered tonnagegross 6,886 / net 6,886
ITC dimensions (L × B × D)381.3 ft × 74.0 ft × 25.0 ft
ITC tonnagegross 7,132 / net 4,898
BuilderBOLLINGER MARINE FABRICATORS LLC · AMELIA, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14215 - Dead Weight, Ton
6886 - Regulatory (Subpart C or D), Gross Ton
7132 - Convention (Subpart B), Gross Ton
6886 - Regulatory (Subpart C or D), Net Ton
4898 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 50
28 April 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8356729
13 November 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8267996
20 August 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8217895
1 May 2025
COI Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8113994
20 March 2025
Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8097185
14 March 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8094038
5 July 2024
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7952698
3 April 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7889181
28 March 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886765
27 September 2023
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7799337
2 May 2023
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7679273
5 May 2022
MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7444411
29 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7420893
31 January 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7388087
24 August 2021
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7294923
12 August 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7284847
7 June 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7218534
4 June 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215498
21 February 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152699
9 January 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7122014
9 December 2020
Deficiency Check · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7109315
7 October 2020
MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7073066
19 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6955772
24 October 2019
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6840977
13 August 2019
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6781937
18 July 2019
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6743743
2 October 2018
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6552929
3 July 2018
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6469656
20 March 2017
MTSA Verification · Internal Structural Exam · Cargo Tank Internal · MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · Drydock Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6107781
25 April 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5862071
23 April 2016
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5862414
12 April 2016
Permit to Proceed · Damage Survey
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5852472
15 May 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5126057
1 April 2015
Periodic Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5093817
14 November 2014
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5023413
10 April 2014
MARPOL Annex II Examination · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4831793
11 August 2013
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4684975
16 March 2012
Internal Structural Exam · COI Inspection · MARPOL Annex VI Survey · Administrative Inspection · MARPOL Annex I Examination · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4265220
9 February 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4241945
5 October 2011
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4161287
5 October 2011
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4161607
16 February 2010
Internal Structural Exam · MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3677019
16 September 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3596579
22 April 2009
Annual Inspection · MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3458068
9 September 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3320781
2 April 2008
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3175940
8 May 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2925041
3 May 2007
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2921390
22 March 2007
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2892563
1 March 2007
Hull Examination · Construction Oversight · Internal Structural Exam · MTSA Verification · COI Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2879985
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 May 2025
Resolved
Transfer equipment tests and inspection: Each non-metallic transfer hose must be tested annually. Vessel to provide documentation attesting to successful hydrostatic testing of the non-metallic hose assemblies and deck cargo pipeline.
33 CFR 156.170
Action required: 703 - Prior to bunkering operations
Resolved 5 May 2025
Resolution: Received proof of clearance.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 1 May 2025
Resolved
Barges equipped with anchors: Barges must be fitted with an operable anchoring system. Owner to weigh anchor to the waterline and recover. Owner to submit documentation attesting to completion of the test with satisfactory results.
46 CFR 32.15-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2025
Resolution: Received video evidence of clearance.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 May 2023
Resolved
Each hose must be marked with the following. Name of product, for oil products "OIL SERVICE" or "HAZMAT SERVICE - SEE LIST".
Two bunker hoses, both vapor hoses and the STBD cargo hose lines (red line aft) are past-due for testing and labeling.
Prior to use. 33 CFR 154.500(e)(1)
Action required: 705 - Other - as specified
Due 19 May 2023
Resolved 23 May 2023
Resolution: Recieved photos and hose testing certificates from vessel rep. see def documents tab for paperwork.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 9 December 2020
Resolved
33 CFR 156.20(n) requires the "Discharge containment required by 33 CFR 154.530, 155.310, and 155.320 to be periodically drained to provide the required capacity." During in-service inspection (transfer monitor), found barge's port/starboard manifold drip trays to be full of ice; rendering the containment systems ineffective. The PIC noted this discrepancy on the Kirby internal 'barge pre-transfer checklist'. Vessel is required to remove the ice from the port/starboard drip trays, prior to the next cargo operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2021
Resolved 10 December 2020
Resolution: Vessel removed ice from drip trays.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 7 October 2020
Resolved
Each liferaft must have a capacity of six persons or more.
Liferaft onboard had a capacity of 04 persons. Liferaft must be replaced at next servicing due date, Jan 2021
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 January 2021
Resolved 24 August 2021
Resolution: Vessel changed route to unmanned.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2020
Resolved
Each cargo vessel must carry the number of lifebuoys prescribed in table 199.271 of this section.
The vessel had 02 lifebuoys onboard, but according to table 199.271, 10 are required. At least one half of the total number of lifebuoys must be fitted with a self-igniting light. At least two lifebuoys must be fitted with a self-activating smoke signal.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 24 August 2021
Resolution: Vessel changed route to unmanned
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 October 2020
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet.
No FCC Station license was onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2020
Resolved 16 November 2020
Resolution: 47 CFR 80.177(a)(5) – No radio operator authorization is required to operate: A ship station operating in the VHF band on board a ship voluntarily equipped with radio and sailing on a domestic voyage. (See narrative)
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 April 2016
Resolved
Horizontal welds in upper portion of aft bulkhead in cargo tank #5 Port are cracked, with signs of cargo leaking on aft side of bulkhead (in aft rake). Grind out affected welds and re-weld, in accordance with CG MI's on-scene direction. Prior to carrying cargo in tank #5.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2016
Resolved 25 April 2016
Resolution: [name withheld] and ABS Surveyor [name withheld] attended the vessel and inspected repairs; all sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 12 April 2016
Resolved
A sheen and smell of cargo was identified in aft void, cargo is leaking from the aft port and/or starboard bulkhead of the number 5 cargo tank. Locate and access leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2016
Resolution: Norfolk, VA: [name withheld] observed leak from tank #5 port aft bulkhead. Leak was ground-out & re-welded on both sides. Visually inspected weld repairs and witnessed 2.0 pressure test of aft rake with negative leakage into cargo tank; all sat.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 12 April 2016
Resolved
Submit repair proposal to OCMI for leaking cargo tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2016
Resolution: Norfolk, VA: [name withheld] observed leak from tank #5 port aft bulkhead. Leak was ground-out & re-welded on both sides. Visually inspected weld repairs and witnessed 2.0 pressure test of aft rake with negative leakage into cargo tank; all sat.
Deck/Cargo › Ballast › Pumps
Issued 5 October 2011
Resolved
Make repairs and prove proper operation of port forward hydraulic ballast pump to the satisfaction of the attending marine inspector prior to ballast operations with the affected pump.
Action required: 705 - Other - as specified
Due 5 November 2011
Resolved 20 October 2011